Welcome Customer !

Membership

Help

Xi'an Zhuofan Petroleum Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Xi'an Zhuofan Petroleum Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 9 Gangkou Avenue, Xi'an International Port Area

Contact Now

X-ray fluorescence sulfur analyzer

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The X-ray fluorescence spectrometer is mainly used to measure the total sulfur (S) content in petroleum products, crude oil, residual oil, lubricating oil, lubricating grease and other petroleum products, as well as materials such as coal, cement, carbon black, etc. Complies with the relevant requirements of national standards GB/T17040-08, GB/T17606-09, GB/T11140-08, ASTM D2622-2007, and ASTM D4294-2003.

Product Details

1、 Main performance characteristics and parameters1. No isotope radioactive sources, no pollution caused by three wastes, and no inconvenience or expenses for users; 2 ZFY-170SX-ray fluorescence sulfur analyzerAdopting a large screen color touch LCD display, with an analysis time of less than 30 seconds; 4. The instrument has a high degree of integration, strong anti-interference ability, high reliability, and accuracy; 5. Automatic C/H ratio correction, suitable for various samples; 6. Each measurement only requires 2ml to 4ml of sample; 7. Multi channel pulse amplitude analyzer using technologies such as CPLD, FPGA, DSP, etc; 8. The instrument has functions such as storage, query, and printing; 9. Replace old CPUs with large-scale integrated circuit CPUs; 10. Replacing the original vertical circuit with a patch circuit has improved the reliability of the hardware; 11. By using a multi-channel pulse amplitude analyzer and a variable gain amplifier, the long-term stability of the instrument has been improved; 12. The GB/T17040 sulfur content analyzer uses a thermal printer to automatically print the results; 13. Using physical analysis methods, without touching or damaging the sample during analysis, without contamination, and without the need for chemical reagents;

2、 Technical parameters

1. Analysis range: The S analysis range can be adjusted and selected by calibrating the working curve;
2. Analysis range width: SmaxSmin ≤ 9.999%, i.e. measurement range S: 0.001% to 9.999%;
3. System analysis time: 1-999 seconds, can be freely set, default is 60 seconds;
4. Detection limit: 10ppm;
5. Usage conditions: at room temperature, relative humidity: ≤ 85%, power supply: 220V ± 20V, 50Hz;
6、ZFY-170SX-ray fluorescence sulfur analyzerPower consumption: ≤ 150W;
7. Size and weight: 560mm × 470mm × 150mm, 23kg.