GC-3200 Chromatograph for BaijiuSpecial chromatograph temperature control parameters
※ Temperature control range: room temperature+5 ℃ to 400 ℃ with an increment of 0.1 ℃;
※ Temperature control accuracy: better than ± 0.01 ℃
※ Program heating: Eight steps, constant temperature time between steps 0-999 minutes
※ Increase by 0.1 minutes/temperature increase by 0.1 ℃
Heating rate: 40 ℃/min below 200 ℃, 20 ℃/min above 200 ℃
※ Temperature control range: room temperature+5 ℃ to 400 ℃ with an increment of 0.1 ℃;
※ Temperature control accuracy: better than ± 0.01 ℃
※ Program heating: Eight steps, constant temperature time between steps 0-999 minutes
※ Increase by 0.1 minutes/temperature increase by 0.1 ℃
Heating rate: 40 ℃/min below 200 ℃, 20 ℃/min above 200 ℃
GC-3200 Chromatograph for BaijiuMain performance of gas chromatograph:
※GB/T10781Total acid in Baijiu,Large screen LCD Chinese display, real-time display of various temperatures and operating conditions, clear and intuitive content, truly realizing human-machine dialogue;
※ Power on self-test, wide range self diagnostic function, can accurately determine the fault location and alarm;
※ Six independent temperature control, eight step programmed heating function;
※ Overtemperature protection function: If any circuit exceeds the set temperature, the instrument will automatically power off and sound an alarm;
The vertical heating device of ※ * ensures more reliable sample vaporization, minimizes the heat radiation generated in the vaporization chamber, and ensures minimal temperature deviation inside the column box;
The intelligent fuzzy control rear door opening system automatically tracks temperature and dynamically adjusts the angle of the air door, truly operating close to room temperature;
※ Equipped with filling column head injection, glass lined injection, capillary split/non split injection device with diaphragm cleaning function, and can be installed with gas injector;
High precision dual stable gas path, capable of installing four types of detectors simultaneously
※ Dual column parallel connection, series connection of TCD thermal conductivity detector, methane conversion furnace, dual FID hydrogen flame detector, and one-time injection can complete the full analysis of nine gas components dissolved in absolute oil, including H2, O2, N2, CO, CO2, CH4, C2H4, C2H6, and C2H2;