- Phone
-
Address
8th Floor, Building 14, Jinshan Zhiyuan Garden, No. 199, Lane 520, Tongning Road, Qianjiang Street, Jiangbei District, Ningbo
Ningbo Ruike Micro Intelligent Technology Co., Ltd
8th Floor, Building 14, Jinshan Zhiyuan Garden, No. 199, Lane 520, Tongning Road, Qianjiang Street, Jiangbei District, Ningbo
Working principle and method of FT-515A pole resistance testing
Working principle and method of FT-515A polarizer resistance testerUsing a flat probe, apply a certain pressure to the tested sample to analyze the overall resistance of the electrode, automatically apply pressure, and the pressure can be set; PC software interface operation, realizing the relationship graph between pressure and resistance, resistivity, and conductivity;

The factors affecting the conductivity of polarizer include the content and distribution of conductive agent, dry powder mixing intensity, compaction density, and the bonding state between current collector and coating
three.Working principle and method of polarizer resistance testingTechnical parameters:
Specification Model |
FT-551A |
FT-551B |
1. Resistance |
10^-5~2×10^5Ω/ |
10^-6~2×10^5Ω |
2. Block resistor |
10^-5~2×10^5Ω/□ |
10^-6~2×10^5Ω/□ |
3. Electrical resistivity |
10^-6~2×10^6Ω-cm |
10-7~2×106Ω-cm |
4. Test current |
0.1μA.μA.0μA, 100μA, 1mA, 10mA,100mA |
1AThe100mAThe10mAThe1mAThe100uAThe10uAThe1uAThe0.1uA |
5. Current accuracy |
±0.1% |
|
6. Resistance accuracy |
≤0.3% |
|
7. PC software operation |
PC software interface: resistance, resistivity, conductivity, square resistance, temperature, unit conversion, temperature coefficient, current, voltage, probe shape, probe spacing, thickness, spectrum, report generation, sample size, pressure setting, pressure; The test results have automatic classification function and can be expanded. |
|
8. Pressure range: |
0-10kg (100N) accuracy not less than ± 0.25N; Other specifications can be customized, such as:(0-1000kg) |
|
9. Plane probe |
Copper material, diameter:10mm; Other specifications can be customized |
|
10. Test itinerary |
0-20mm, Displacement accuracy 0.01mm |
|
11. Pressurization method |
automatic(Automatically run after setting the value) |
|
12. Safety protection |
Equipped with limited range and pressure protectionMisoperation and emergency stop protection; Abnormal alarm |
|
13. Maintenance and upkeep |
Equipped with safety standard operation prompt signsMaintenance reminder |
|
14. Power supply |
input: AC 220V±10%.50Hz power consumption:<100W |
|
15. Selection of Items |
select1. Linear probe; Purchase 2. Testing platform; 3. Standard resistors. 4. Computers and printers |
|
Working principle and method of FT-515A polarizer resistance tester