Overview
Handheld biotoxicity detector is a toxicity detection system based on biological fluorescence sensing technology, which qualitatively detects the changes in luminescence intensity of luminescent bacteria during metabolism. Compared with traditional biological detection methods such as fish, fleas, and other aquatic organisms, the national standard luminescent bacteria method is simple, fast, sensitive, adaptable, repeatable, accurate, low-cost, and widely used. It is a water toxicity rapid detection instrument designed for environmental pollution, emergency accidents, security checks, and routine testing purposes, and can be used for overall toxicity detection of heavy metals, toxic agents, nerve agents, pesticide formulations, and other substances in water on site.
Product Details




Product Introduction:

Handheld biotoxicity detector is a toxicity detection system based on biological fluorescence sensing technology, which qualitatively detects the changes in luminescence intensity of luminescent bacteria during metabolism. Compared with traditional biological detection methods such as fish, fleas, and other aquatic organisms, the national standard luminescent bacteria method is simple, fast, sensitive, adaptable, repeatable, accurate, low-cost, and widely used. It is a water toxicity rapid detection instrument designed for environmental pollution, emergency accidents, security checks, and routine testing purposes, and can be used for overall toxicity detection of heavy metals, toxic agents, nerve agents, pesticide formulations, and other substances in water on site.

The instrument complies with national standardsGB/T15441-1995 Determination of Acute Toxicity of Water Quality - Luminescent Bacteria Method "and International Standard (ISO11348-3).

Application industry:

widely used inDrinking water testing and emergency response-Biological pollution, emergency response - toxic chemicals, toxic and hazardous waste, municipal drainage, rainwater testing, drilling fluid and mud testing, mining industry, soil and water body testing, industrial wastewater discharge testing, process water testing, seawater testing, medical/pharmaceutical product testing, food packaging testing, personal protective equipment and household chemical testing, sediment testing, rainwater runoff testing, solid sample testing, food processing water testing, etc.

Detection principle:

The handheld biotoxicity detector performs three functions: toxicity testingATP detection and determination of microbial contamination; Conduct toxicity testing using luminescent bacteria found in nature, which emit light during normal metabolic processes. If placed in a toxic environment, their cellular respiration process is affected, resulting in a decrease in luminescence. The HD-DXS luminescent detector measures the luminescence of luminescent bacteria before and after exposure to toxic environments, and the degree of reduction in luminescence corresponds to the strength of toxicity.

Technical Specifications:

display screen:3.5-inch true color touch screen, eliminating tedious button operations and making it more convenient;

Operating System:Android intelligent operating system, more intelligent and user-friendly;

Measurement modes: Quick measurement mode, Basic measurement modeATP measurement mode;

Detection range: for areas beyond the vicinityA biological early warning system sensitive to over 5000 toxic compounds;

Detector: silicon photomultiplier tube;

Spectral range:300-1100nm;

ATP sensitivity: 10-1510-18 mol;

Strain: Compliant with The strains specified in ISO11348&GB/T 15441-1995 standards include Vibrio fischeri and Vibrio cholerae;

Method standard:GB/T 15441-1995 & ISO 11348;

Detection sleeve: adopting a flexible plug-in design, it can be regularly cleaned and used for a long time, extending the service life of the instrument;

Measurement range:0~65535 RLU (relative luminescence unit);

ATP detection limit: 9.4 × 10-15 mol ATP, RLU reading ≤ 2;

ATP repeatability: When the instrument reading is around 100RLU, the relative standard deviation of repeated measurements is ≤ 2.3% (n=10);

ATP linear error: When the instrument reading is around 100RLU, the measured linear error is ≥ -3.6%;

Toxicity testing accuracy: sample3 repetitions with a relative deviation of less than 6%;

Curve concentration points: A curve can have tens of thousands of curve concentration points, which can be added by oneself without manual recording, ensuring more accurate curve values;

spirit Min Degree: Equivalent to or better than fish body96 hour cultivation test method for acute biotoxicity determination;

Toxicity testing time: after sample preparationObtain results within 5 minutes;

ATP testing time: 15 seconds after sample preparation to obtain results;

Display result: Light suppression rate(%)/Relative Luminescence Unit (RLU)/Toxicity Warning (Low toxicity, Poisoning, Heavy toxicity, High toxicity, Highly toxic) displayed in accordance with national standards;

System settings: The upload address, sample name, testing personnel, testing location, contact phone number, etc. can be set by oneself;

Background noise level:≤6RLU(n=10);

Limit setting:ATP mode can set up and down line values, making it easier to determine the pass rate through sampling;

Monitoring platform: equipped with a monitoring platform that enables wireless transmission of data to relevant monitoring platforms, achieving real-time data and better meeting the scenario requirements of regulatory authorities;

Operating environment: Storage temperature -10-50 ℃, working temperature+5-45 ℃;

relative humidity30-95%(25°C);

Data storage:ROM≥4GB, Can store over 80000 items;

Communication:WIFI、 Hot topics RS232、 Bluetooth USB;

battery3500mAh lithium battery, with a standby time of over 10 hours;

Built in input method: Sogou input method, which can edit Chinese and English information;

Literature search: Built in web browser, can search for relevant literature after networking;

Continuous working hours:More than 10 hours;

Charging voltage:220V/5V;

Size:188 ×77×37mm;

Positioning function: optionalGPS positioning function, real-time display of detection location information, making field measurements more convenient;

Configuration list: