- Phone
-
Address
Room 121, Building 2, No. 655 Gaoji Road, Sijing Town, Songjiang District, Shanghai
Shanghai Tingheng Weighing Instrument Co., Ltd
Room 121, Building 2, No. 655 Gaoji Road, Sijing Town, Songjiang District, Shanghai
Product Name:Wireless electronic weighing scale
Scale sensitivity:1t 2t 3t 5t 10t
Product Material:A36 structural patterned steel and U-shaped steel
Product technology: High precisionA
Battery capacity:4V/4mA maintenance free battery
Product functions: weighing, counting, accumulating and other functions
Battery usage: Built in battery (AC/DC dual-use)
divide degree Value:0.2kg-2kg
Table size:0.6*0.8m 0.8*1m 1*1m 1*1.2m 1.2*1.2m 1.2*1.5m 1.5*1.5m 1.5*2m 2*2m 1.5*3m 2*3m 2*4m
Would you choose a weighing scale? Shi Run teaches you how to choose a weighing scale.
Measuring and weighing 3 tons, 1.5m × 2m wireless transmission electronic weighing scale
AW1 monitorConnected to the wireless junction box through2.4GofISMWireless transmission in frequency band, unobstructed transmissionDistance reached20 Above meters. have4 Automatic frequency hopping for segments, automatically skipping frequency bands with high interference, can work withWIFIShared Bluetooth and other technologies.AW1adjustable30 An independent communication channel, up to one locationuse simultaneously30 setAW1Instrumentation and supporting wireless junction box.There are two types of wireless junction boxes, one is an analog wireless junction box that can be connected1~4 Only simulate sensingWhen the number of connections is greater than1 When necessary, an additional analog junction box is required. Another type is digital wireless connectionWire box, connectable1 Only digital sensors with our company's communication protocol.The wireless junction box adopts ultra-low power consumption design and intelligent sleep technology, with standby time up to2 monthAbove, the continuous working time can reach120 Hour (analog wireless junction box). Wireless junction box canBy turning on and off the corresponding instrument, automatic wake-up and sleep can be achieved without the need for manual switching. moduleThe proposed wireless junction box is powered by two lithium batteries connected in series, and the lithium batteries can be replaced by themselvesWhen replacing, pay attention to the installation polarity and do not2 Install sections in reverse.

Measuring and weighing 3 tons, 1.5m × 2m wireless transmission electronic weighing scaleParameters
1, Typenumber:XK3190-AW1
2Accuracy:Level IIIn=3000
3Wireless frequency:2.4G
4Number of wireless channels:30 One (automatic frequency hopping)
5Wireless transmission distance:greater than or equal to20 Meter (unobstructed)
6Display:6 bit0.8 Inch digital tube13 A status indicator
7Keyboard:6 A thin film button
8AC power supply:AC 220V/50 Hz
9DC power supply:Built in maintenance free6V/4AHBattery
10Working time of battery:40 Hour (typical value, continuous use after fully charged)
11Fuse:0.5A
12Preheating time:10 Minutes
13Communication interface:1 roadRS232Output, can be connected to computers, large screens, and specified models of micro printersOptional Bluetooth2.0 Slave mode,PIN=1234(None)RS232Output)
14Work/Storage and transportation temperature:0~40℃/ -25℃~55℃
15External dimensions:242×185×164
Power on zeroing and manual zeroing
1Set to zero upon startupAfter the self-test of the startup stroke is completed, if the weight value on the scale is less than the full range10%(Relative to calibration)Zero point), the instrument automatically resets to zero, and the gross weight is displayed as0
2Manually reset to zeroIn the weighing state, if the weight value on the scale is less than the full range4%(Relative to the zero point at startup),Press the "zero" button to set the current weight as the zero point, and the gross weight will be displayed as0
Peeling operation
1Peel off the skinIn the weighing state, if the gross weight is greater than zero and stable, press the "peel" button to adjust the current gross weightRemove the tare weight and display the net weight as0The peeling label is on.
2Cancel peelingIn the weighing state, if the gross weight is equal to or less than zero and in the skinless state, press the "skinless" button toReset the current tare weight to zero and turn off the tare marker.
Maintenance and Precautions
One To ensure clarity and longevity of the instrument, it should not be used in direct sunlight and should be placed on a relatively flat surface.
II Not suitable for use in places with severe dust and vibration, avoid using in damp environments, and keep away from highly corrosive objects,
Stay away from flammable and explosive materials.
▲! Do not use in environments with flammable gases or vapors; Do not use in pressure vessel canning systems.
▲! In areas where lightning strikes frequently, reliable lightning arresters must be installed to ensure the personal safety of operators,
Prevent lightning strikes from damaging instruments and corresponding equipment.
▲! Signal sources and instruments are both static sensitive devices, and anti-static measures must be taken during use. It is strictly prohibited to use them
Perform welding or other strong electric field operations on the measuring device; Reliable avoidance measures must be implemented during thunderstorm season
Lightning measures are taken to prevent damage to signal sources and instruments caused by lightning strikes, ensuring the personal safety of operators
Safe operation of weighing equipment and related devices.
III This instrument, wireless junction box, and supporting battery do not have waterproof capability and are prohibited from being soaked in water.
4 It is strictly prohibited to use strong solvents (such as benzene and nitro oil) to clean the machine casing.
Five Do not inject liquids or other conductive particles into the instrument or wireless junction box to prevent damage to the instrument and electric shock.
VI Before plugging or unplugging the instrument and connecting it to external devices, the power supply of the instrument and corresponding equipment must be cut off first!
7 The external interface of the instrument must be strictly used according to the methods indicated in the user manual, and the connection cannot be changed without authorization. This table is in use
If any malfunction occurs during the process, the plug should be immediately unplugged and sent to a professional factory for repair. Non professional manufacturers are generally advised not to repair on their own
To avoid causing greater damage.