Welcome Customer !

Membership

Help

Wuhan Tonghui Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Wuhan Tonghui Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 14, 8th Floor, Building 3, Dahankou International Digital City, east of Huanhu Road and west of Beijing Guangzhou Railway, Fukou Street, Huangpi District, Wuhan City, Hubei Province

Contact Now

Water quality monitoring infrared spectrophotometer oil analyzer

NegotiableUpdate on 05/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The infrared spectrophotometer for water quality monitoring is mainly used for measuring the oil content in surface water, groundwater, and industrial wastewater. It can also be used for monitoring the oil content in flue gas and solids in the catering industry. This instrument is a professional instrument for measuring the oil content in water, gases, and solids.

Product Details

  Water quality monitoring infrared spectrophotometer oil analyzerBasic principle: When a monochromatic light passes through the measured solution, its energy will be absorbed. The intensity of light absorption is proportional to the concentration of the substance being measured, in accordance with Lambert Beer's law: A=log (1/T)=log (I0/I)=a × b × c

Meet the standards:

Complies with national standard: "HJ637-2018 Determination of Water Quality, Petroleum and Animal and Vegetable Oils - Infrared Spectrometric Method"

HJ 1077-2019 Determination of oil fume and oil mist from fixed sources of pollution - Infrared spectrophotometric method

HJ 1051-2019 Determination of petroleum in soil by infrared spectrophotometry

Compliant with national standard: "GB3838-2002 Surface Water Environmental Quality Standard"

Compliant with national standard: "GB18483-2001 Emission Standard for Cooking Fumes in the Catering Industry"

Compliant with national standard: "GB18918-2002 Pollutant Discharge Standard for Urban Sewage Treatment Plants"

Compliant with petroleum standards: "SY/T 0530-2011 Determination of oil content in oilfield produced water - spectrophotometric method"

Compliant with oilfield standards: "DB65/T 3998-2017 Pollution Control Requirements for Comprehensive Utilization of Oil containing Sludge in Oil and Gas Fields"

  Water quality monitoring infrared spectrophotometer oil analyzerApplication scope: This instrument is mainly used for measuring oil content in surface water, groundwater, and industrial wastewater. It can also be used for monitoring oil content in flue gas and solids in the catering industry. This instrument is a professional instrument for measuring the oil content in water, gases, and solids.

The THF2000 model is widely used in various industries, including environmental monitoring systems in various departments, testing rooms and laboratories in large and medium-sized enterprises such as petrochemical, hydrological and water conservancy, tap water, sewage treatment plants, thermal power plants, steel enterprises, university research and teaching, textile and chemical fiber, agricultural environmental monitoring, railway environmental monitoring, automobile manufacturing, marine environmental monitoring, transportation environmental monitoring, and environmental research.

Instrument features:

■ Can simultaneously measure the oil content of tested substances such as liquids, solids, gases, etc

High accuracy: The error of each measurement does not exceed ± 1.0%

Baseline drift less than 0.0005AU/60min, automatic wavelength calibration

Integrated design of opto mechatronics and electrically modulated light source to improve instrument reliability

■ Zero point automatic adjustment, automatic adjustment of instrument full-scale value

The instrument is connected to a computer using RS232 or USB2.0/3.0 interfaces

■ It has functions such as mathematical statistics, spectrum display, storage, printing, etc

Good software compatibility can be used for operating systems such as Win7, Win10, etc

■ It has the function of measuring instrument calibration coefficient

■ Direct reading function with non dispersive measurement results, no need for conversion

Can test the purity of carbon tetrachloride and tetrachloroethylene

Other non carbon chlorine organic solvents such as S-316, carbon tetrachloride, tetrachloroethylene, and trichlorotrifluoroethane can be used as extractants

Technical specifications of THF2000 model:

The maximum DI detection concentration is 0.0008mg/L (enriched by 100 times the oil concentration in water)

◆ Maximum measured concentration: 96000mg/L oil in water

Wave number range: 3400cm-1 to 2400cm-1 (2940nm to 4167nm)

◆ Adjustable scanning wavenumber range: 4200cm-1 to 2000cm-1

Wave number accuracy: ± 1cm-1

Wave number repeatability: ± 1cm-1

Detection limit: DL ≤ 0.04mg/L (3 times SD of 11 blank measurements)

◆ Absorption range: 0.00000 to 4.00000 AU, with adjustable 4-stage range

Basic measurement range: 0-900.00mg/L (no dilution required, software adjustable);

The relative standard deviation (RSD) of repeatability is less than 0.6% for standard oil samples with a concentration of 20-30mg/mL

Linear correlation coefficient R>0.999

◆ Instrument calibration: Calibration coefficient calibration and standard curve calibration are optional

Methyl resolution>3%

Sample analysis time: Full spectrum scanning: 30 seconds (software adjustable scanning range)

Multiple fixed-point scans: 10 seconds

Non dispersive infrared method: 2 seconds

◆ Blank solvent zeroing: automatic

◆ Environmental temperature: 5 ℃~35 ℃

Relative humidity: 20% to 80%

◆ Overall dimensions of the host: 470mm (length) x 330mm (width) x 150mm (height)

◆ Host power supply: 220VAC, 50Hz