Vickers HV, Rockwell HRC, Brinell HB ultrasonic hardness tester

NegotiableUpdate on 12/28
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Vickers HV, Rockwell HRC, Brinell HB ultrasonic hardness tester TIME5630 $r $n Ultrasonic hardness tester is a portable hardness tester that has attracted much attention in recent years. This instrument has little damage to the surface of the specimen and can be considered as a non-destructive hardness testing device. At the same time, it has fast testing speed, high accuracy, and can measure locally hardened components in small spaces, as well as thin parts, making up for the limitations of desktop hardness testers. Application scenarios: The measurable parts of the workpiece include strip/plate workpiece measurement, mold hardening layer measurement, blade hardening layer measurement, tooth surface hardening layer measurement, and flange edge measurement
Product Details

Vickers HV, Rockwell HRC, Brinell HB ultrasonic hardness testerTIME5630

TIME5630 Ultrasonic Hardness Tester Product Introduction

Ultrasonic hardness tester is a portable hardness tester that has attracted much attention in recent years. This instrument has little damage to the surface of the specimen and can be considered as a non-destructive hardness testing device. At the same time, it has fast detection speed, high accuracy, and can measure locally hardened components in small spaces, as well as thin parts, making up for the limitations of desktop hardness testers and being popular in the market.

Application scenarios: Measurable parts of workpieces include belts/Measurement of plate-like workpieces, mold hardening layer, blade hardening layer, tooth surface hardening layer, flange edge measurement, wheel and turbine rotor measurement, thin plate measurement, shaft and pipeline, container measurement, blade position measurement, welding part measurement, etc.

meet the standardThe performance indicators of TIME5630 ultrasonic hardness tester meet the requirements of GB/T34205-2017 Metallic Materials Hardness Test Ultrasonic Contact Impedance Method.

Measurement principle: Ultrasonic impedance method.

Product composition: host, probe, connecting cable.

Measuring hardness: VickersHV, Roche HRC, Brinell HB

TIME5630 Ultrasonic Hardness Tester Product Features

Battery level indicator: icon display;

Alarm indication: low battery alarm;

Menu text: switchable between Simplified Chinese and English;

Multiple hardness systems can be converted to each other: universalConversion of HV, HB, HRC hardness values;

Calibration function: hardness value calibration function, deletion calibration function;

Material selection: The tested material can be selected, mainly steel and cast steel. After calibration with standard test blocks, it can be used for measuring alloy tool steel, special cast iron, and non-ferrous metals;

Storage: Built in8GB SD card, providing massive storage space;

Omnidirectional free measurement: Measurements in all directions can be taken directly without compensation;

Measurement value display: It can display the maximum value, minimum value, average value, standard deviation, measurement frequency, and previous measurement values.

Over limit alarm: can set the upper and lower limits of hardness values, and provide over limit alarm prompts;

Display mode:3.5-inch color LCD display;

Battery: rechargeable lithium-ion battery, with a continuous working time of not less than30 hours;

Interchangeability: The host and probe adopt a separate design, connected by cables, and the probe, host, and probe protective cover are interchangeable;

Measurement bracket, meeting the requirementsThe requirements of section 3.6 of JB/T 9377-2010 "Technical Conditions for Ultrasonic Hardness Testers" make the measurement more stable.
Vickers HV, Rockwell HRC, Brinell HB ultrasonic hardness testerTIME5630

TIME5630 Ultrasonic Hardness Tester Technical Parameters

Experimental force:10N or 20N, repeatability ≤ 3%;

Pressure head: Use a Vickers pressure head, with the angle between the two opposing surfaces at the top of the pressure head136 ° ± 0.5 °Any intersection line (horizontal blade) between the opposing surfaces should not exceed 0.005mm;

Hardness tester reading resolution:1HV;

Measurement range: VickersHV80-1042; Roche HRC20-70; Brinell HB 100-450

The indication error conforms to《The requirements of GB/T34205-2017 Metallic Materials Hardness Test Ultrasonic Contact Impedance Method comply with the German standard DIN50159. (measured with a 10N probe)

Vickers hardness range

Allowable value of indication error


<250HV

± 4%


250HV ~ 500HV

± 4%


>500HV ~ 800HV

± 5%


800HV

± 6%


Brinell hardness range

Allowable value of indication error

100-450

± 4%

Rockwell hardness range

Allowable value of indication error

HRC20-70

± 2HRC

Host dimensions:169*73*37mm;

Host weight:≤500g;

TIME5630 Ultrasonic Hardness Tester Basic Configuration

One host

One 10N or 20N probe

One connecting cable

One set of charger

One copy of the instruction manual