Vacuum pumpFor users who need to meet both blowing and suction requirements, high-pressure fans are a very good choice. Jiangsu Kelsen Environmental Protection Technology Co., Ltd., a manufacturer of double bladed high-pressure fans, double stage vortex blowers, and bipolar vortex air pumps, has received support and love from a large number of customers since its entry into the market. The high-pressure vortex blower is processed by high CNC machine tools, with motor insulation grade TEFC IP55 standard, insulation grade H, and a body temperature resistance of up to 180 degrees. The fan is environmentally friendly, efficient, energy-saving, high-pressure, high air volume, low-noise, small in size, and lightweight.Vortex blowerIt is a widely used universal air source fan that can blow or suck air. It is made of aluminum alloy material, which greatly reduces weight and achieves the goal of lightweighting. The so-called sewage aeration refers to continuously injecting air into the water or using mechanical agitation to dissolve oxygen from the air into the water
Vacuum suction high-pressure fanAdopting precision cast aluminum die-casting, it is sealed and dustproof, reinforced and shockproof, low frequency and noise proof, beautiful and smooth appearance, oil-free and waterless operation, stable performance, strong pressure, large air volume, long durability, three-year warranty, and seven day no reason return.
Vortex high-pressure fanProduct Features:Dual use of blowing and suction, it can blow or suck air. Save electricity, reduce energy consumption, save production costs, and achieve a power saving rate of over 20%. Improving the power factor of the power grid and saving on-site compensation devices can significantly increase the power factor of the power grid. Smooth start eliminates high current surges during startup, and the motor current can be limited to within 120% of its rated current during startup. Reduce the wear of motor bearings and other moving parts, and extend their service life. Equipped with * protection and self-protection functions to ensure the safe operation of the equipment. The equipment failure rate has decreased, reliability has improved, spare parts consumption has been reduced, and maintenance costs have been lowered. Switching between mains power and energy-saving, fans and intelligent control energy-saving devices have * mains power and energy-saving conversion functions. In special circumstances, if the energy-saving speed controller fails, it can switch to mains power operation without affecting the normal operation of the equipment.
Working principle of vacuum vortex fan:
1. Industrial vacuum cleaners use high-pressure fan impellers to operate at high speed, generating suction and pressure to create a local vacuum inside the dust collector
Under the action of suction and pressure, air is expelled at high speed, and the air in the suction part at the front end of the high-pressure fan continuously replenishes the air in the fan, causing an instantaneous vacuum inside the vacuum cleaner and forming a negative pressure brush with the external atmospheric pressure. The long connecting pipe, hose, bent pipe, hose joint enter the dust filter bag, and dust and other debris are trapped in the dust filter bag. After being purified by the filter, the air is discharged from the exhaust outlet at the tail of the organism!
3. High pressure fans use suction power in industrial vacuum cleaners to create air circulation and vacuum, collecting dust and other debris through pipes.

1. Check the fastening condition of each part and whether there is any looseness in the positioning pin
2. There is no oil leakage inside the blower body
3. There should be no scaling, rusting, or peeling inside the blower body
4. Pay attention to whether the lubrication and heat dissipation are normal, pay attention to the quality of the lubricating oil, regularly listen to the operation of the blower for any noise, pay attention to whether the unit is running under non compliant working conditions, and regularly add butter
5. The overload of the blower is sometimes not immediately displayed, so attention should be paid to the increasing trend of the intake and exhaust pressure, bearing temperature, and motor current to determine whether the machine is running normally
6. Before disassembling the machine, the dimensions of each fitting should be measured, recorded, and marked on the components to ensure that the original fitting requirements are maintained after assembly
Vacuum suction high-pressure fanInstallation precautions:
1. Installation location: It must be installed indoors in a place that is not affected by wind and rain
2. Environmental temperature: below 40 ℃
3. Relative humidity: below 80%
4. Air quality: If there are corrosive or flammable gases such as acids and alkalis in the air, they should not be transported by high-pressure blowers to avoid danger
5. Dust protection: Avoid using in places with large amounts of dust, powder, or fibers. If it is necessary to use in such places, please install a filter and regularly clean the dust attached to the filter and inside the high-pressure blower
6. Ventilation and heat dissipation: Please choose to use it in a well ventilated place and not in a sealed room or box
7. Placement space: For the convenience of column maintenance or repair, please avoid installing in overly narrow locations