UV/Visible Illuminometer

NegotiableUpdate on 01/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The UV/visible light illuminance meter adopts SMT surface mount technology, uses high-precision and low-power digital chips, has a streamlined design for the instrument housing, and the detector has undergone strict spectral and angular characteristic correction, with stable performance and strong applicability. The instrument integrates two functions: ultraviolet irradiance measurement and illuminance measurement, and is widely used in various fields such as photochemistry, polymer material aging, non-destructive testing, ultraviolet light sources, plant cultivation, large-scale integrated circuit industry, agriculture, construction, environment, health, scientific research, etc.

Product Details

ultraviolet/Visible light illuminance meter/Visible light illuminance meter/UV irradiance meter/UV illuminance meter Model:H18443

ultraviolet/Visible light illuminance meteradoptSMT surface mount technology uses high-precision and low-power digital chips, with a streamlined design for the instrument casing. The detector undergoes strict spectral and angular characteristic calibration, resulting in stable performance and strong applicability. The instrument integrates two functions: ultraviolet irradiance measurement and illuminance measurement, and is widely used in various fields such as photochemistry, polymer material aging, non-destructive testing, ultraviolet light sources, plant cultivation, large-scale integrated circuit industry, agriculture, construction, environment, health, scientific research, etc.

feature

*Spectral and angular characteristics have been rigorously calibrated

*Digital LCD display with backlight

*Manual/automatic range switching

*Digital output interface (USB, redundant power supply)

*Low battery reminder

*Automatic delayed shutdown

*There are numbers to keep

*Tap the button to operate, beep for prompt

Main technical indicators

Illuminance: The measurement performance meets the requirements《JJG 245-2005 Illuminometer

The first level standard of the Metrological Verification Regulations.

*Measurement range: (0.1~200000) lx

*Relative indication error: ± 4%

*V (l) matching error: 6%

*Cosine characteristic (directional response) error: 4%

Linear error:±1%

*Shift error: ± 1%

*Fatigue error: -0.5%

*Temperature coefficient (%/° C): ± 0.5

*Response time:<1 second

UV irradiance: The measurement performance meets the requirements《JJG 879-2015 UV

The first level standard for the metrological verification of radiometer.

*Wavelength range and peak wavelength:

λ: (315-400) nm; λ p = 365 nm

*Range of irradiance measurement: (0.1~200000) mW/cm2

*Relative indication error: ± 8%

*Cosine characteristic (directional response) error: 10%

*Linear error: ± 1.5%

*Shift error: ± 1%

*Short term instability: ± 1% (after 30 minutes of startup)

*Fatigue error: 3%

*Zero value error (full-scale FS): ± 1%

*Response time: 1 second

*Usage environment: Temperature (0-40) ° C, humidity<85% RH

Size and weight:160mm×78mm×43mm; 0.2kg

*Power supply: One 6F22 type 9V laminated battery is commonly used,

Can also be connected using a data cableUSB interface, 5V power adapter






2.Milk analyzer/Dairy analyzer/Milk Composition Analyzer/Milk analyzerH18442

1、 Product Introduction

The rapid dairy product analyzer is a specialized equipment used for multi index analysis and detection of liquid dairy products in terms of physical and chemical properties. They have multiple functions and parameter measurement options to evaluate the quality and nutritional value of dairy products.

This instrument is mainly used for fat, protein, lactose, non fat solids, density, water content, freezing point, ash content, temperature, etc. in dairy productsPHMeasurement of values and conductivity, suitable for milk and goat milkUHTAnalysis of milk, camel milk, etc. is an instrument used by modern ranches, fresh milk purchasing stations, and small and medium-sized dairy enterprises to monitor the quality of dairy products.

The application of ultrasonic sensors to automatically correct the effects of acidity and temperature is suitable for detecting most liquid milk.

2、 Main features

1TheAndroidIntelligent system, easier and faster to use

27Inch touch screen, better operation and interaction experience

3Simplify internal pipelines

4Low sample demand, good repeatability of testing, and low power consumption

5Using a peristaltic pump to prevent milk residue

6Built in automatic cleaning function, only requires simple cleaning and maintenance, no need for chemical reagents

7Equipped with a built-in thermal printer, it can flexibly edit and print inspection reports

8, possessingwifiConnected, data can be wirelessly uploaded to the platform orPC

9Configure a data management platform to store uploaded data for a long time and conduct analysis and management of both short-term and long-term data

3.Slurry concentration measurement and control systemPulp concentration regulator Model:H18441

1、 Overview:

1. System Introduction:

H18441The automatic measurement and control system for pulp concentration is a generation of pulp concentration measurement system, which is used to replace the previously used knife type with low sensitivity and poor stability(including static and dynamic knives) and cone type external rotation concentration adjustment.

The characteristic of this system is high measurement and control accuracy, which can accurately measure and control the concentration of pulp, thereby stabilizing paper quantification. Multiple paper mill applications have shown that this system is significantly better than other types of pulp concentration regulators in terms of technical performance and usage effectiveness. .

H18441The automatic measurement and control system for slurry concentration has strong applicability, stability, and reliability. Many systems have been successfully applied in situations where concentration applications have failed in the past, such as corrugated paper with low beating degree, box board pulp, etc. The quantitative stability effect of using this system for cultural pulp and news pulp with high beating degree.

The system has a compact structure, small size, short installation and debugging time, and basically does not affect production during installation. Therefore, installation can be carried out by taking breaks during shutdown, which is easy to operate and use, with fast and stable concentration adjustment speed and strong anti-interference ability. Can operate continuously and stably for a long time without human monitoring.

2. System composition and functions of each component:

The concentration measurement and control instrument consists of four parts: concentration transmitter, slurry collection cylinder, electric control valve, and main unit. The main unit is based on the single-chip computer of Intel Corporation in the United States, using sensing and self-control technology, and integrating electromechanical information processing. The system can continuously detect the concentration of slurry in the slurry pipeline online, and the concentration signal is sent to the computer (main unit) by the concentration transmitter. The computer processes the concentration signal sent and eliminates various interference signals. The actual detected concentration value is calculated according to a certain conversion relationship, and compared with the set concentration value according to the process requirements. The opening and closing degree of the electric valve is automatically adjusted according to the deviation, thereby adjusting the dilution water volume and achieving the purpose of stabilizing and adjusting the concentration of slurry at the outlet of the slurry pipeline. This system controls the concentration of the slurry by adjusting the dilution water volume, so it can only dilute higher concentration slurry to the required concentration of the process, and cannot concentrate slurry below the required concentration of the process.

1) The pulp sampling cylinder consists of an inlet cylinder, a return cylinder, and a shut-off valve, and is made of stainless steel. The function of the pulp inlet cylinder is to take a path of pulp for the sensor to measure pulp concentration. The function of the slurry return cylinder is to allow the slurry to flow back into the slurry circulation system. The function of the shut-off valve is to control the flow rate and flow rate of the slurry in the pipeline.

2) The sensor consists of a stainless steel casing, a drive motor, a speed measurement electronic circuit, and an impeller. The stainless steel casing and its sealing components, as well as the oil seal design, are important benefits for the sensor to function properly in harsh environments. Drive the motor to achieve high standards for the lifespan and reliability of the sensor. The electronic circuit for measuring rotational speed is used to acquire and transmit electronic signals. The impeller is used to obtain signals of pulp concentration changes

3) The host is composed of a chassis, a display, and internal electronic circuits. The chassis is small and lightweight, easy to install, and the monitor is used to display pulp concentration and valve opening.

4) The regulating valve is used to control the amount of water added to the pulp path, in order to achieve concentration control of the pulp in the pulp path.

5) Connecting cables are used to achieve signal transmission between the host and sensors, as well as between the host and regulating valves.

3. Scope of application:

The concentration measurement and control instrument is mainly suitable for various stages of pulp concentration measurement and control in the pulp and paper process of papermaking enterprises.

(1) The regulation of pulp concentration in the pulp conveying pipe between the pulp tank and the stabilizing tank is used to stabilize the pulp concentration, thereby stabilizing the amount of pulp discharged and achieving the goal of stable paper production.

(2) Used for measuring and controlling the slurry concentration before the disc mill to improve the quality and yield of the pulping machine.

(3) Used for measuring and controlling the concentration of slurry before the three-stage tower float, to stabilize production, reduce costs, and minimize pollution.

(4) Measurement and control of pulp concentration during the transportation of pulp from the pulp making workshop to the papermaking workshop.

(5) In the process of mixing and preparing different pulp materials such as wood pulp, straw pulp, and damaged pulp, the measurement and control of concentration can achieve the goal of stable pulp ratio.

4. Main technical indicators:

(1) Concentration measurement and control range: 1.00% to 6.00%

(2) Detection sensitivity: ± 0.01%

(3) Concentration control accuracy: ± 0.02%

(4) Input current signal: 4-20mA

(5) Display: Two channel four digit digital display

(6) Two way switch output: AC220V 10A

(7) Power supply voltage: three-phase four wire system

(8) Operating environment: 10~+40 ℃, relative humidity 20~85%

(9) Dimensions 350 × 350 × 120 (in millimeters)

(10) Adjustment cycle: can be set from 1 second to 40 seconds

(11) Adjustment ratio: adjustable; 5~500

(12) Continuous working hours: Long term

(13) Flow rate range: 0.2-2.5 m/s

4.Dip Coater/Vertical Pulling Machine/Pulling Coating MachineH18440

oneProduct application

This product is mainly used for sol-Thin film materials were prepared by liquid phase methods such as gel method. Immerse the clean and dry substrate into a solution (sol), and vertically lift the immersed substrate at a certain speed using pre-set parameters. A layer of film is attached to the substrate, which is called "wet gel film". With the evaporation of solvent in the "wet gel film" film, the film is solidified on the substrate into a "dry gel film". After further drying and high-temperature heat treatment, the "dry gel film" can obtain the required nano film materials. The thickness of the film layer is determined by the pulling speed, liquid concentration, and liquid viscosity.

twoProduct Introduction

Dip CoaterIt is specifically designed for liquid phase (especiallyDesigned for the research work of preparing thin film materials using sol-gel method, thin films are grown by immersing and pulling different liquids. The pulling speed, lifting height, immersion time, coating frequency (multiple multi-layer coatings), and coating interval time are all continuously adjustable and precisely controlled. There are no special requirements for the coating substrate, and sheet, block, cylindrical, etc. can all be coated. Stable operation and no liquid level vibration during operation can greatly improve experimental accuracy and efficiency.

Suitable for surface coating processes of all solid materials such as silicon wafers, chips, glass, ceramics, metals, etc. Applied to scientific research and product production.

threeProduct Features

1. Adopting motor-driven vertical lifting device and program control system to ensure operational accuracy and stability; The high precision, smoothness, and no shaking characteristics of servo motors during operation are incomparable to stepper motors. The vertical lifting device has the characteristics of high precision, seamless transmission, smooth operation, corrosion resistance, maintenance free, and long service life.

2. Multi parameter fully automatic program control. There are six parameter settings: descent speed, immersion time, pulling speed, coating frequency, and coating interval time, all of which are continuously adjustable and precisely controlled. After the coating program is set, the entire coating process from descent to immersion, and then to pulling the coating is fully automated.

3. Both high and low speeds run smoothly, and there is no vibration on the liquid surface during coating, making the film layer more uniform and free of stripes.

4. Adopting a 7-inch LCD touch screen makes control more convenient. During runtime, various parameters are displayed in real-time,

More intuitive understanding of the coating process.

5. Both upper and lower ends are equipped with limit sensors, which automatically stop at the limit during lifting or lowering operation to avoid exceeding the limit during lifting or lowering.

6. The flat mouth fixture used evenly grips the sample on both sides without damaging it.

fourTechnical parameters

1. Pulling speed range: 1~6000 μ m/s, * small resolution 1 μ m/s;

(There is also a low speed0.1μm/s、0.01μm/s 产品)

2. Speed accuracy: -0.02% to+0.02%;

3. Journey: Approximately 400 mm (subject to actual measurement)

4. Coated substrate size: MIN 10 × 10 mm, MAX 100 × 100 mm, thickness MAX 10mm;

5. Immersion time: 1-3600 seconds, * small resolution of 1 second;

6. Coating frequency: 1-100 times, * less than 1 time;

7. Interval time for each coating: 1-3600 seconds, with a small resolution of 1 second;

8. Drive mode: stepper motor

9. Power supply: 220V/50Hz;

5.Automatic saccharification machine/Automatic saccharification machine/protocol saccharification machineH18439

Easy to operate,

Automatic water inlet

Imported components

Stainless steel material

Easy maintenance.

L runs quietly

LCD display

Program control

Automatic saccharification machine, it is a beer and malt experiment

Instrument Introduction:

The automatic saccharification machine is based on A malt analysis specialized equipment designed according to the technical requirements of EBC analysis method.

Mainly used to analyze the saccharification power, saccharification time, and extract of malt and auxiliary materials. This instrument adopts computer technology and can accurately

Reliable temperature control and timing control for malt saccharification process, with digital displays featuring timed and constant temperature alarms. yes

Ideal saccharification experimental equipment for malt factories, breweries, and related scientific research and teaching units.

8 holes

Automatic water inlet

LCD display screen, real-time display of time and temperature, switchable display of temperature curve

The inner cavity is made of stainless steel material

The top cover of the sink is made of polished stainless steel material

At any time during the saccharification process, time and temperature parameters are displayed on the screen

Technical Specifications:

Temperature control point40 ℃, 45 ℃, 70 ℃, any temperature constant temperature

temperature control accuracy+/-0.1℃

voltage220V/50HZ

heating power3.1kW

fixed procedure Malt saccharification, saccharification power, rice saccharification optional custom program6 of them

temperature range room temperature+5-80℃

The maximum number of program steps per optional program10 of them

Maximum duration for each program0-99 minutes

heating rate1 ℃ per minute, adjustable from 0.5~1.5 ℃

stirring speed50~150rpm adjustable

The above parameter information corresponds to the image