Traction tester/Pullometer/Traction and Parking Brake Force Test Model:H18413
Traction testerModified vehicles, trailers, semi-trailer tractors, work vehicles, buses, new energy vehicles Tractor, combine harvester
High traction and parking brake force testing
I. Overview
The tension meter is suitable for testing the traction force and parking braking force of automobiles, tractors, construction machinery, and other wheeled or tracked vehicles. It can display both strong and real-time force values simultaneously, using high-performance integrated circuits as the test data processing unit, with two A/D signal inputs, LCD display, and Chinese operation menu. It has the characteristics of accurate testing, intuitive display, and stable performance.
Equipped with a standard RS232 interface, it can easily transmit data with the main control machine. Real time data output,.
This tester can cyclically store 50 sets of test values. After shutdown, data will not be lost.
You can also choose an external micro printer to print test results in real-time
2、 Technical parameters
1. Environmental temperature: (0-50) ℃
2. Relative humidity: ≤ 85% (no dew drops)
3. Internal power supply: DC 7.4V rechargeable lithium battery.
4. Charging power supply: DC 8.4V (0.5A)
5. Host measurement range: 0-999.9KN (sensors can be configured with 10 tons/20 tons according to customer requirements).
6. Measurement accuracy: ± 0.5%.
7. Host resolution: 0.1KN.
8. Standard 9-pin RS232 interface. (3-pin signal output, 2-pin signal input, 5-pin signal ground).
9. Baud rate 9600, data bits 8, stop bit 1, no checksum.
10. Dimensions: 190 × 95 × 40 mm
We can also customize the measuring range according to customer testing requirements
2.Transformer Ratio Tester/Transformer Ratio Tester/Transformer Ratio Model:H18412
Multiple testing modes: single-phase testing, three-phase testing, three-phase blind testing, Z-type testing
Large capacity storage: capable of storing 500 sets of test data.
Wide measurement range: Transformation ratio 0.9~100000
Measurement accuracy: When the transformation ratio is between 0.9 and 2000, the accuracy is
0.2%, with an accuracy of 0.5% between 2000 and 10000 hours
Resolution: 0.0001
Support computer control; Support Bluetooth APP remote control
3.Steering parameter tester/Steering parameter testerH18411
The instrument uses high-performance A/D conversion devices for digital to analog conversion, ensuring accurate and stable test data. Chinese character LCD display, clear and intuitive, beautiful appearance, and easy to use.
The instrument can store 100 sets of test data and is also equipped with a standard RS232 interface, which can send test results to other computers. It can also flexibly form an online testing system with other devices or computers.
Corner testing does not require a central positioning rod, making installation and testing convenient.
II Technical performance indicators
Internal power supply: DC 8.4V (1200mAh nickel hydrogen battery pack)
Measurement range: Steering wheel torque: (-200~+200) N.m
Steering wheel steering force: ≤ 999.9 N
Steering wheel angle: ≤± 1080 °
Resolution: Steering wheel torque: 0.1 N.m
Steering wheel steering force: 0.1 N
Steering wheel angle: 0.1 °
Measurement accuracy: Steering wheel torque: ± 2% F · S
Steering wheel steering force: ± 2% F · S
Steering wheel angle: ± 2 °
Standard 9-pin RS232 interface. (3-pin signal output, 2-pin signal input, 5-pin signal ground). Baud rate 9600, data bits 8, stop bit 1, no checksum.
4.Graphite acid analyzer/acid analyzer/graphite acid electric heating plate with CEM microwave digestion tubeH18410
digit 16 \ \ 20 \ \ 25 \ \ 36 \ \ 40 \ \ 48 bits, customizable
Heating method: 3D wrapped heating PID temperature control digital display
1. Split type, the controller can be placed outside the fume hood and separated from the digestion unit to avoid corrosion of electronic components.
2. Closed design effectively prevents heat loss while avoiding acid mist invasion
Temperature control range: room temperature -220 ℃
Temperature control accuracy: ± 1 ℃
Uniformity between holes: temperature difference between adjacent holes ≤ 1.5 ℃, uniform heating temperature
Plate surface temperature difference: The temperature difference of the same plate surface (middle and corners) does not exceed 3-5 ℃, effectively ensuring sample uniformity and high experimental efficiency
Surface anti-corrosion of heating plate
Rated voltage heating power: 2-3KW
Continuous working time:>48 hours
Supporting product: 55ml microwave digestion tube (different models of microwave digestion tubes can be customized)
5.Yerkes selector/Multi selector/Yerkes selectorH18409
This instrument is used for thinking experiments and can measure the subjects' ability to grasp the formation process and ability of various simple and complex spatial position concepts. It can also understand the subjects' ability to analyze and summarize problems.
1、 Composition:
1. One participant consists of 12 buttons and 12 indicator lights.
The main test team consists of 24 buttons and 36 indicator lights, of which 12 buttons and 12 indicator lights are set regularly; There are also 12 buttons and 12 indicator lights for participants to choose from for setting; The other 12 indicator lights are displayed after the test button is pressed. The power switch and the reset button of the whole machine are also on the main test side. During the experiment, the experimenter sets the selection positions and rules for the subjects according to certain principles, and the subjects' buttons are connected to the experimenter's light and sound as the conceptual positions for setting.
2. There is a screen in the middle, and the subjects cannot see the main subject's operation.
2、 Usage:
1. Open the upper cover, align the two holes in front of the cover with the two pins on the panel, insert them into the panel as a screen.
2. Plug in the power supply (~220V) and sit on both sides of the screen for the main test and the subjects.
3. The experimenter determines that the subjects need to form a spatial concept, that is, the sound is connected to a button that conforms to a certain spatial position relationship, and designs several specific schemes according to certain principles (refer to the examples in the appendix).
4. The experimenter presses the "Set Position for Subject Selection" button, and the subject indicator light lights up. The experimenter then presses another "Rule Setting" button to select the position connected to the sound for the set concept position.
5. Participants will select a button from the illuminated buttons that is connected to the sound and remember its location.
6. After multiple attempts, the subjects. Press the correct button three times in a row and state the principle of selection correctly. Participants should also explain how they have mastered this principle.
Note that the left-right relationship between the subject and the experimenter is opposite .
At the end of an experiment, press the reset button to reset the entire machine, turn off all indicator lights, and start a new experiment.
The above parameter information corresponds to the image