Welcome Customer !

Membership

Help

Beijing Hengaode Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Hengaode Instrument Co., Ltd

  • E-mail

    2272048995@qq.com

  • Phone

    15811023934

  • Address

    Fuhai Center, Haidian District, Beijing

Contact Now

Handheld turbidity detector

NegotiableUpdate on 01/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Handheld turbidity detector is used to measure the scattering degree of light generated by insoluble particulate matter suspended in water or transparent liquids, and can quantitatively characterize the content of these suspended particulate matter

Product Details

Handheld turbidity detector/Turbidity meter/portable turbidity detector/water turbidityH18423

Handheld turbidity detectorUsed to measure the scattering degree of light generated by insoluble particulate matter suspended in water or transparent liquids, and to quantitatively characterize the content of these suspended particulate matter

Application industry:
It can be widely used for turbidity measurement in power plants, purified water plants, water plants, domestic sewage treatment plants, beverage plants, environmental protection departments, industrial water, liquor and pharmaceutical industries, epidemic prevention departments, hospitals, chemical products and other departments

Instrument features:
Android intelligent system is easy and fast to operate;
Built in operation process, simple operation, no need for training, direct hands-on experience;
Fast detection speed, on-site data reading;
Portable with small size, light weight, and convenient for outdoor testing;
Compact and beautiful in appearance, stable and maintenance free in operation,
Adopting imported cold light source, with stable optical performance and a lifespan of up to 100000 hours;
Parameter indicators:
Test item: Turbidity
Measurement standard: GB13200-91
Measurement range: 0.5~300 (NTU)
Wavelength range: 340~800nm
Measurement method: photoelectric colorimetry
Measurement error: ≤ 5%
Repeatability:<0.5%
Stability:<0.5%
Wavelength selection: automatic
Operating System: Android Intelligent Operating System
Display screen: 3.5-inch color LCD touch screen
Sensitivity (absorbance): 0.001
Usage environment: Temperature 0-50 ℃, humidity 0-90%
Data storage: over 80000 records
Communication: Type-C, WIFI, hotspot, Bluetooth
Battery: 5600mAh lithium battery
Continuous working time: 12 hours
Supply voltage: 5V/DC DC
Size: 180mm * 80mm * 70mm
Weight: 700g
Supported languages: Simplified Chinese or English




2.Radiant heat flux meter/Light irradiation meter/Radiant heat meter/Radiant heat meter model:H18422

Thermal radiation and heat flux testing instrument, in compliance with GBZ2 "Occupational Exposure Limits for Hazardous Factors in the Workplace" andGB/T4200Standards such as "Classification of High Temperature Operations". It can directly measure the radiant heat value, which is both simple and fast.

The instrument adopts digital display, with high accuracy, intuitive readings, and reliable use. It can be used for measuring the meteorological conditions of high-temperature working environments and calculating human body heat balance in fields such as labor hygiene, labor protection, heating and ventilation.

2、 Performance characteristics

W/m²And Btu/(ft²-h) Two choices of units

4 1/2 digit display

Data retention function

Wide range without shifting gears

3、 Specifications

Resolution: 01W/m²、0.1 Btu/(ft²-h)

Error range:±(10%R+2dgt)R: Reading

Temperature error:±0.38W/m²/[ ±0.12Btu/(ft²-h)/]deviate25At ℃

Display: 4-1/2 digitsLCDDisplay, show numerical values19999Overload display'OL'

Measurement range: 0.1-1999.9W/m²、0.1-1999.9 Btu/(ft²-h)

Wavelength range: 340nm-1100nm, incident angle extends in the normal direction±Peak wavelength within 45 degrees900nm

Sampling rate:2.5time/second

Operating temperature and humidity:0°CUp to 40°Cless than80%RH

Storage temperature and humidity:-10°CUp to 50°Cless than70%RH

Size:132(L)60(W)38(H)mm

Weight: Approximately150g

Battery specification: 6F22 alkaline9Vbattery

Battery life: approximately 100 hours

3.Sulfate radical rapid analyzer/Sulfate radical analyzer/Sulfate radical centrifuge/Sulfate radical rapid analyzerH18421

Sulfate radical rapid analyzer (dual digital display - time and speed)

The sulfuric acid rapid analyzer is easy to operate and is used for on-site rapid analysis in chrome plating production workshops (to determine the sulfate content in chrome plating solutions), controlling the sulfuric acid content in chrome plating tanks. It can also be extended to rapid determination of sulfate content in other solutions. Composed of an acid centrifuge and two sulfate measuring tubes

The measurement range is 0.2-5g/L.

Easy to use, fast, and with minimal error, no need to create a working curve, and can accurately determine the content of sulfate ions in the plating solution in just ten minutes. It solves the disadvantages of complex, time-consuming, and high error detection of titration and weight methods, and is an instrument for analyzing chrome plating processes.


① Electric centrifuge (power supply, 220V, 50HZ)
② Two rapid sulfuric acid measuring tubes, plugged, with a measurement range of 0.2-5g/L.
③ . Pipette (self provided) 1 20ml, 2 5ml

Dimensions: Length * Width * Height 36 * 36 * 33cm

Weight: 20kg

Reagent preparation:
① . 3:1 hydrochloric acid solution: Mix 3 volumes of hydrochloric acid and 1 volume of distilled water.
② 0.25% Barium Chloride Solution: Dissolve 250 grams of analytical grade barium chloride in 1000 milliliters of distilled water
Analysis method:
1. Take the chrome plating solution and cool it to room temperature. (If the solution is not clean, filter it.) Use a pipette to take 20 milliliters of the above solution and place it in a rapid sulfuric acid measuring tube. Add 5 milliliters of 3:1 hydrochloric acid to the pipette, shake well, add 5 milliliters of 25% barium chloride solution, cover with a lid, and shake well.
2. Place the centrifuge tube into the electric centrifuge and operate in the following order:
Check for accuracy and cover the panel - check and adjust the speed regulator to zero position - turn on the power - set the instrument timer to the 4-minute position - gradually increase the speed regulator to 1400 rpm.
3. After the centrifuge stops rotating, turn the speed controller back to zero and turn off the power switch. Take out the reading of the centrifuge tube, and the scale value of the centrifuge tube is the sulfuric acid content (g/L).
Notes:
1. The centrifuge should be placed firmly. Two centrifuge tubes must be placed into the centrifuge simultaneously and filled with the same volume of solution, otherwise it will become unbalanced during high-speed operation and damage the centrifuge.
2. The centrifuge tube has undergone calibration and balanced pairing, and should be used in pairs.
3. After the measurement is completed, immediately adjust the speed controller to zero position and clean the centrifuge tube, pipette, etc. in a timely manner

4.Skin Electrical Tester/Skin Resistance Tester/Skin Electrical DetectorH18420

1、 Instrument Description:

During emotional states, changes in blood vessel dilation and contraction, as well as sweat gland secretion, can cause changes in skin resistance. The skin conductance tester is used to measure the emotional response of the autonomic nervous system. Skin conductance testing is commonly used as an indirect indicator of individual emotions and stress. It can measure the intensity of emotions, tension, and arousal levels.

2、 Main technical indicators:

1) LCD displays real-time changes in skin conductance, displaying waveforms and values of changes in skin conductance.

2) Embedded color touch screen, capable of touch screen operation, equipped with built-in speakers.

3) To prevent noise, the voice guidance can be adjusted by touch when the sound is too loud or too small.

(4) Real time sampling period: 0.1 seconds, record the experimental time.

5) No need for a main trial, individuals can operate independently.

6) Each page displays a graph of changes in skin conductance within 30 seconds, which can be zoomed in or out.

7) Measurement range: The schematic value of skin conductance is 0.050-5.000 µ S, and the corresponding skin resistance is 200K Ω -20M Ω

8) Equipped with headphone jack, it can listen to voice prompts through headphones, effectively avoiding voice interference during multi person testing.

(9) To prevent noise, the size of the sound can be adjusted by touch, data viewing records, modification of student ID, modification time, export of reports, deletion of records, and other functions. The test data can be imported into a USB flash drive through a USB data interface

5Automatic chloride ion potentiometric titrator/chloride ion automatic potentiometric titrator/cement chloride ion automatic potentiometric titratorH18419

Zhushu

The fully automatic chloride ion potentiometric titrator is a device developed by our company based on the new standard for measuring chloride ion concentration using the chloride ion potentiometric titration method. This instrument is suitable for testing laboratories in various industries such as cement enterprises, testing institutions, mixing plants, research institutes, and universities. This device adopts a 7-inch touch screen, with simple and intuitive parameter input operation. Real time display of titration capacity and electrode potential on the page. The titration device adopts a 25ml large capacity sampler and a 0.1ml titration head to ensure accurate titration. The equipment adopts high-precision corrosion-resistant three-way solenoid valve for injection, which is convenient for sample absorption and experimental titration.

This machine has an automatic blank test titration function, which automatically measures, records, and stores relevant test data. The operator can call up the test data at any time and modify the parameters before the test.

2、 Technical parameters

1. Titration analysis repeatability: 0.2%.

2. Allowable error for titration capacity: ± 0.035ml.

3. Resolution of burette: 2/10000.

4. Discharge or suction speed of burette: 30 ± 10s.

5. Potential measurement range: -500~2500mV.

6. Potential resolution: 0.1mV.

7. Basic potential error: ± 0.03% FS:

8. Potential stability: ± 0.1mV.

9. Input power supply: AC220V/50HZ:

10. Power: 50W.

11. Record: 200 entries.

The above parameter information corresponds to the image