Tiger Optics_Prismatic3 Multi component Gas Analysis

NegotiableUpdate on 01/28
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Tiger Optics Prismatic3 is a highly efficient real-time gas analyzer based on powerful cavity ring down spectroscopy (CRDS) technology, capable of analyzing ppb levels of CO, CO2, H2O, and CH4. It is widely used in various applications in factories and laboratories. Especially in the field of hydrogen fuel cells, Prismatic 3 is an ideal solution for analyzing hydrogen purity. From production to transportation, and then to storage, it covers the entire hydrogen supply chain.
Product Details

Tiger Optics Prismatic 3 Multi Component Gas Analyzer


Prismatic 3 product features

Simultaneously analyze ppb levels of CO, CO2, H2O, and CH4
Low operating costs: no calibration, no maintenance. No need to configure carrier gas zero point gas path gas
The analyzer meets the hydrogen purity requirements of SAE J2719 and ISO 14687:2019
Easy to install, measurement method in accordance with ASTM D7941
● Powerful cavity ring down spectroscopy (CRDS) technology

With the multi-component laser analyzer PrismaticWith the launch of 3, Tiger Optics has achieved a huge breakthrough in technology.

Prismatic 3 is a highly efficient real-time gas analyzer widely used in various applications in factories and laboratories. Especially in the field of hydrogen fuel cells, Prismatic 3 is an ideal solution for analyzing hydrogen purity. From production to transportation, and then to storage, it covers the entire hydrogen supply chain.

This analyzer based on CRDS technology can simultaneously analyze H2O, CO, CO2, and CH4 at PPB to PPM levels. Meet the requirements of SAE J2719 and ISO 14687:2019.

In addition, the Prismatic 3 instrument is very easy to install and the touch screen operation is very convenient. Through the touch screen, users can intuitively understand the analysis results and data curves. The instrument has no consumables or spare parts, and the maintenance cost is extremely low. No calibration is required during operation, and there is no need to configure zero point gas, range gas, and carrier gas.

performance
Please refer to the table below for the scope of work
The detection limit (LDL, 3 σ/24h) is shown in the table below
Accuracy (1 σ, whichever is greater) ± 0.75% or 1/3 of LDL
Accuracy (whichever is higher) ± 4% or LDL
Response time<5 minutes to 95% (during four channel operation)
Environmental conditions: 10 ℃ to 40 ℃, relative humidity: 30% to 80% (without condensation)
Storage temperature -10 ℃ to 50 ℃

Gas processing system and conditions
Material 3 16L stainless steel 10 Ra surface finish
Gas connection 1/4 "VCR male inlet and outlet
Leakage test 1 x 10-9 mbar l/sec
Gas inlet pressure 10 − 125 PSI (1.7 − 9.6 bara)
Gas flow rate~1.0 slpm (under nitrogen)
The sample gas is mostly inert, hydrogen or oxygen
Gas temperature is 60 ℃ higher