Three box type thermal shock test chamber

NegotiableUpdate on 05/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Three box type thermal shock test chamber

Product Details

Cold and hot shock testing machine, used to test material structures or composite materials, to determine their ability to withstand continuous environments of extreme high and low temperatures in an instant

To test the chemical changes or physical damage caused by thermal expansion and contraction in the shortest possible time. Applicable objects include batteries

Materials such as metal, plastic, rubber, and electronics can serve as the basis or reference for product improvement.

Cold & thermal impact tester is used to test the capability of material structure or composite materials to withstand

the continuous environmental changes between extremely high temperature and low temperatures during a short

period, and therefore understand the chemical changes or physical damages caused by expansion from heat and

contraction from cold in the shortest possible time. It is applicable to Lithium-ion battery,metals, plastic, rubber,

electronics amongst other, Lithium-ion battery. The test result can be used as a reference or basis for product

improvement.

Features Features

The three box equipment is divided into three parts: high temperature zone, low temperature zone, and testing zone. The test product is placed in the testing zone, and the temperature in the high temperature zone is pressed into the test for impact. The test product is static.

Adopting a touch based graphical control interface. Easy to operate the cylinder.

The impact method applies the air path switching method to import the temperature into the testing area and conduct cold and hot impact tests.

During high temperature impact or low humidity impact, the maximum time can reach 999H and the maximum cycle period can reach 9999 times.

The system can perform automatic cyclic movement or manual selective impact, and can set the start of second or third zone impact and cold and hot impact.

The cooling system adopts a binary freezing system, which has a fast dehumidification effect and is water-cooled.

Can test impact at room temperature

Divided into three areas:high temperature,low temperature, the three-part test area, testing products placed on the

test,when the impact of high temperature or cold temperatures into the area of impact testing area

Using touch-control graph control as operation interface, easy to operate.

Applying wind route conversion to the shock method to distribute temperature to the testing zone for cold and thermal

shock measurement.

For high temperature shock or low temperature shock,ma x i mum time is up to 999H,and maximum circulation cycles

are 9999 times.

The system can be used fo r automatic Circulation Shock or manual selective shock, capable of setting two zones or

three zones shocks as well as cold and thermal shock start-up.

Binary cooling system is adopted for cooling,with quick cooling effect.The method is water cooling.

Normal temperature shocd test is allowed.

Technical Parameter

Model number

RL-I-42(A-C)

RL-I-80(A-C)

RL-I-100(A-C)

RL-I-150(A-C)

RL-I-252(A-C)

RL-l-450(A-C)

Internal dimensions WxHxD (cm)

40x35x40

50x40x40

50x45x45

60x50x50

70x60x60

80x75x75

External dimensions WxHxD (cm)

140x185x145

150x193x153

150x195x160

160x220x185

175x212x197

190x227x221

temperature range

Temperature Range

(150t-A:-45C;B:-55 C;C: 65t); (High temperature zone:+60 ℃ -+1500; Low temperature zone: -10C -65C)

Heating time (heat storage area)

TeatingTime (regenerative)

RT-200 ℃ takes about 35 minutes

Cooling time (cold storage zone)

Cooling Time (storage)

RT - about 55 minutes at 70 ℃

Temperature response time/conversion time

Temperature Response Time Change

_5min /<5sec

Temperature control picking/distribution accuracy

Soil 0.5C/12.5% C

Internal and external materials

The outer box is treated with SUS304 # stainless steel surface stripes, while the inner box is made of SUS304 # stainless steel

The external box is the SUS304# stainless steel surface strips,the inner box is SUS304# stainless steel.

Insulation material

High temperature resistant high-density aluminum silicate fiber cotton or PU foam insulation material

Heat-resistance high-density aluminum silicate fiber cotton or PU foam insulator materials

system

P. I.D+S.R+microcomputer balanced temperature control system

P.I.D+S.S.R+Micro-computer balanced temperature control system

Cooling system

Semi closed two-stage compressor (water-cooled)/fully closed two-stage compressor (air-cooled)

Saemrnermeuc aouoie-stage compressor twater-cooiea type) irmermeuc aouoie-stage compressor Lair-cooiea type,

Protector

Non fuse switch, compressor high and low pressure protection switch, refrigerant high pressure protection switch, fault warning system, electronic alarm

Non-fuse breaker high and low.

Pressure protective switch of the compressor, refrigerator high-pressure protective switch, failure warning system,electronic alarm

accessory

Observation window (special optional type), two adjustable compartments, power measuring holes, casters, horizontal bracket

Viewing window (special order),shelves(freely adjustable,2pcs),power-on test cable port,castor,horizontal support

compressor

France's Tecumseh Brand

power supply

AC380V 50HZ/6HZ3

controller

Republic of KoreaTEMlKoreaTEMlOr JapanOYOBrand JapansOYOBrand Optional

weight

700Kg

900Kg

1100Kg

1200Kg

1400Kg

1900Kg

compressor

France "Taikang" brand France/sTecumsehBrand Germany Bizelle Germans