WS-2C(YYL)Temperature monitoring device
Operation Instructions:
1. Panel Description
(1) PV1 and PV2 are the first and second channel display windows: normal display of vibration measurement values; Display parameters and parameter value symbols in parameter modification state.
(2) SP2 and SP4 indicator lights: When this indicator light is on, there is output from the corresponding channel of the lower limit relay on the instrument.
(3) SP1 and SP3 indicator lights: When this indicator light is on, there is output from the corresponding channel of the upper limit relay on the instrument.
(7) SET key: Press the key for 1 second to enter the parameter modification state; Press SET again to enter the next parameter value modification state.
(8) Shift key(►)Pressing this key while modifying parameters can move the position of the modified number.
(9) Number reduction key(▼)Number reduction can be achieved in parameter modification, given value modification, or manual adjustment states.
(10) Number increase key(▲)Number increase can be achieved through parameter modification, given value modification, or manual adjustment.
(11) Return key (MAN): When the instrument is in operation, press the (SET) key first and then the (MAN) key to enter the parameter setting state in Table 2. After each parameter modification is completed, press the (SET) key to confirm and automatically switch to the next menu until the setting is exited and the instrument automatically switches to normal operation state. Pressing the SET and MAN keys simultaneously during the parameter setting process can exit the currently set parameters and enter the measurement state.


WS-2C(YYL)Temperature monitoring device
sensor(Input):
ZW-2A temperature vibration integrated probe(Waterproof; wire length)20M)
2. Number of channels: Dual channels
3. Measurement range
Vibration speed:0-1000mm/s (adjustable);
Temperature:0-100 ° C (adjustable)
4. Alarm and control: divided into two stages of alarm: the first stage is warning (SP2, SP4), which controls the output relay to work; The second stage is the alarm (SP1, SP3), which controls the operation of the output relay
5. Warning and alarm setting range: any set value within the measurement range
6Speed value display error: < 1%
7. Output: 0-1000mm/s;0-100°CCorresponding measurement values0―100mA
output
8Relay contact output: AC220V/5A(resistive load) orAC220V/0.3A(inductive load), Normally open (adjustable)
9. Working power supply: 85-240V 50/60Hz
10. External dimensions: Panel Size:160(Long)80mm in height;
Opening size: 152+1×76+1Mm; Depth: 88mm
11. Working environment: a non corrosive gas environment with a temperature range of -10 to 60.0 ℃, a relative humidity not exceeding 85, and a place without strong electromagnetic interference