Overview

The DS-WLDE tap water flow meter consists of two parts: a sensor and a converter. It works based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive liquids with a conductivity greater than 5 μ S/cm. It is an inductive instrument for measuring the volumetric flow rate of conductive media. In addition to measuring the volumetric flow rate of general conductive liquids, it can also be used to measure the volumetric flow rate of strong corrosive liquids such as strong acids and alkalis, as well as homogeneous liquid-solid two-phase suspensions such as mud, slurry, and pulp. Widely used in industries such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, as well as municipal management, water conservancy construction, river dredging, and other fields

Product Details

Tap water flow meter - Jiangsu Dingsheng Instrument Co., Ltd
The DS-WLDE tap water flow meter consists of two parts: a sensor and a converter. It works based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive liquids with a conductivity greater than 5 μ S/cm. It is an inductive instrument for measuring the volumetric flow rate of conductive media. In addition to measuring the volumetric flow rate of general conductive liquids, it can also be used to measure the volumetric flow rate of strong corrosive liquids such as strong acids and alkalis, as well as homogeneous liquid-solid two-phase suspensions such as mud, slurry, and pulp. Widely used in industrial sectors such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, as well as municipal management, water conservancy construction, river dredging and other fields for flow measurement.
1、 Product features of tap water flow meter:
·All digital processing, strong anti-interference ability, reliable measurement, high accuracy, and a flow measurement range of up to 150:1
·Adopting a 16 bit embedded microprocessor, it has fast computing speed, high accuracy, programmable low-frequency rectangular wave excitation, improved stability of flow measurement, and low power consumption.
·Using SMD devices and surface mount technology, the circuit has high reliability.
·There are no movable parts or flow blocking components inside the pipeline, and there is almost no additional pressure loss during measurement.
·On site, the range can be modified online according to the actual needs of the user.
·The measurement results are independent of physical parameters such as flow velocity distribution, fluid pressure, temperature, density, viscosity, etc.
·High definition backlit LCD display, fully Chinese menu operation, easy to use, simple to operate, easy to learn and understand.
·It has digital communication signal outputs such as RS485, RS232, Hart, and Modbus. (Optional)
·It has self checking and self judging functions.
·Hourly total volume recording function, recording the total flow volume in hours, suitable for time-sharing measurement system (optional)
·There are three integrators inside that can display the forward cumulative amount, reverse cumulative amount, and difference cumulative amount respectively. There is also a non power outage timer inside that can record 16 power outage times. (Optional)
·Infrared handheld operator, 115KHZ communication speed, all functions of long-distance non-contact operation converter (optional)
2、 Technical parameters of tap water flow meter:
Nominal diameter (mm)
(Special specifications can be customized)
Pipeline type: DN10 to DN3000
Insertion type: DN200~DN3000
Flow direction: Positive, negative, net traffic
Range ratio: 150:1
Repetitive error: ± 0.1% of the measured value
Accuracy level: Pipeline type: 0.5 level, 1.0 level
Temperature of the tested medium: Ordinary rubber lining: -20 to+60 ℃
High temperature rubber lining: -20 to+90 ℃
PTFE lining: -30 to+100 ℃
High temperature PTFE lining: -20 to+180 ℃
Rated working pressure:
(High voltage can be customized)
DN6-DN80:≤1.6MPa
DN100-DN250:≤1.0MPa
DN300-DN1200:≤0.6MPa
Flow rate range: 0.1-15m/s
Conductivity range: The conductivity of the measured fluid is ≥ 5 μ s/cm
Current output: load resistor 0~10mA:0~1.5kΩ
4~20mA:0~750 kΩ
Digital frequency output: The upper limit of the output frequency can be set within 1-5000Hz with a transistor collector open circuit bidirectional output with photoelectric isolation. When the external power supply is ≤ 35V and conducting, the collector Z has a high current of 250mA
Power supply: AC220V, DC24V or 3.6V batteries
Require the length of the straight pipe section Upstream ≥ 5DN, downstream ≥ 2DN
Connection method: The flowmeter and piping are connected by flanges, and the flange connection size should comply with the provisions of GB11988
Explosion proof grade: mdIIBT4
Protection level: IP65, Specially customized * up to IP68
Ambient temperature -25~+60℃
Relative temperature: 5%~95%
Total power consumption: Less than 20W


Selection code table:

model Explanation
DS-WYLDE -□ -□
Path diameter 10-2200mm
Combination S Integrated type
L Split type
Electrode material M Stainless steel
T Ti (titanium)
D Ta(钽)
H Hastelloy alloy
P Pt platinum
N Ni nickel
Output method 0 No output
1 4-20mA/1-5KHz
2 4-20mA
Lining material X Rubber
F Polytetrafluoroethylene
P Polyethylene
J Polyurethane rubber
On site display 0 No on-site display
1 On site display
Communication method 0 No communication
1 RS485
2 RS232
3 Modus Bottom
4 Hart
Grounding 0 No grounding ring
1 There is a grounding ring
2 There is a grounding electrode
Maximum traffic limit (n) Upper limit flow rate (range) m3/h
Work pressure A 0.6MPa
B 1.0 MPa
C 1.6 MPa
D 2,5 MPa
measurement accuracy 1 0.2
2 0.5
3 1
medium temperature L 0-80 degrees
H 0-150 degrees
Power supplier DC 24V DC power supply
AC 220V AC power supply

Lining material selection table:

Lining material Main performance Scope of application
neoprene
Neoprene
Good wear resistance, elasticity, high tensile strength, and resistance to corrosion from low concentration acid-base salt media, but not resistant to corrosion from oxidizing media. <80 ° C, general water, sewage, mud, slurry
polyurethane rubber
Polyurethane
Has * wear resistance, slightly inferior acid and alkali resistance. <60 ° C, neutral and strongly worn mineral slurry, coal slurry, and mud.
Polytetrafluoroethylene
PTFE
A material with stable chemical properties, capable of withstanding boiling hydrochloric acid, sulfuric acid, nitric acid, aqua regia, concentrated alkali, and various organic solvents, but not resistant to chlorine trifluoride. <180 ° C, strong corrosive media such as concentrated acid and alkali, sanitary media.
F46 Chemical stability, electrical insulation, lubricity, non adhesiveness, and non flammability are similar to PTFE, but F46 material has better strength, aging resistance, temperature resistance, and low-temperature flexibility than PTFE. Good adhesion to metal, better wear resistance than PTFE, with good performance
The tear resistance performance.
<180 ° C, hydrochloric acid, sulfuric acid, aqua regia, and strong oxidants, sanitary media


Selection of electrode materials:

material corrosion resistance
316L For nitric acid, sulfuric acid at room temperature<5%, boiling phosphoric acid, alkaline solution; Under certain pressure, media such as sulfurous acid, seawater, and acetic acid have strong corrosion resistance.
Hastelloy HB Resistant to all concentrations of hydrochloric acid and sulfuric acid at boiling pointOrganic acids and other non oxidizing acids, bases, and non chlorinated hydrochloric acid.
Hastelloy HC Resistant to oxidizing acids such as nitric acid, mixed acids, or mixtures of chromic acid and sulfuric acid, as well as oxidizing salts and seawater
Titanium It can withstand corrosion from seawater, various chlorides and hypochlorites, oxidizing acids (including fuming nitric acid), organic acids, alkalis, etc. It is not resistant to corrosion from relatively pure reducing acids (sulfuric acid, hydrochloric acid), but corrosion is greatly reduced when the acid contains oxidants (such as nitric acid and media containing Fe and Cu ions).
Tantalum Has excellent corrosion resistance similar to glass, exceptExcept for concentrated sulfuric acid, it can withstand corrosion from almost all chemical media (including boiling point hydrochloric acid, nitric acid, and sulfuric acid below 175 ° C), but is not resistant to corrosion in alkali.

3、 Installation Record of Dingsheng Electromagnetic Flow Meter: