Swiss VAT 590 series electric high fidelity air conditioning valve

NegotiableUpdate on 05/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Swiss VAT 590 series electric high fidelity air conditioning valve $r $n Product type: Electric driven high fidelity air conditioning valve (Proportional Control Valve) $r $n $r $n Core function: $r $n $r $n Precision pressure regulation (10 ⁻ n); #179; ~10 ⁻⁹ mbar range) $r $n $r $n dynamic flow control (applicable to CVD, PVD, etching and other processes)

Product Details

Swiss VAT 590 series electric high fidelity air conditioning valve

1、 590 series product positioning

  • Product TypeElectric driven proportional control valve for high fidelity air conditioning

  • core functionality

    • Precision pressure regulation(10 ⁻³~10 ⁻⁹ mbar range)

    • Dynamic flow control (applicable to CVD, PVD, etching and other processes)

  • core advantage

    • Resolution up to0.1% full scaleResponse time<50ms

    • All metal seal (leakage rate<1 × 10 ⁻¹¹ mbar · L/s)

    • supportAnalog quantity (0-10V/4-20mA)AndDigital communication (RS485/Profibus)control


2、 Model Naming Rules (Taking VAT 590.12-AA as an Example)

code snippet meaning
590 Series Name (Electric Control Valve)
.12 Diameter size (12=DN25, 18=DN40)
-AA Sealing material (AA=fluororubber, MM=metal)

3、 Comparison of commonly used sub models in the Chinese market

model path control signal Sealing material leak rate Typical application scenarios
VAT 590.12-AA DN25 0-10V/4-20mA fluororubber <1×10 ⁻⁹ mbar·L/s Laboratory vacuum system
VAT 590.18-MM DN40 RS485/Profibus metal seal <1×10 ⁻ ¹¹ mbar·L/s Semiconductor ALD equipment
VAT 590.24-MM DN63 0-10V metal seal <1×10 ⁻ ¹¹ mbar·L/s Air inlet control of photovoltaic coating chamber

4、 Core technical parameters

  1. performance tuning

    • linearity: ± 0.5% full scale

    • repeatability accuracy:±0.2%

    • Flow coefficient (Cv):0.02(DN25)~0.15(DN63)

  2. Electrical Characteristics

    • Power supply voltage: 24V DC ± 10%

    • Power consumption:<15W (standby<5W)

    • Position feedback: Optional 0-10V or SSI absolute encoder

  3. environmental adaptability

    • Fluororubber seal: -20 ° C~+150 ° C

    • Metal seal: -200 ° C~+250 ° C (baking condition)

    • Temperature range:

    • Corrosion resistance: compatible with process gases such as Cl ₂, NF ∝, etc. (nickel plated valve body optional)


5、 Key steps for selection

  1. Determine the diameter

    • Select DN25/DN40/DN63 based on traffic demand

    • Calculation formula:𝑄=𝐶𝑣Δ𝑃𝜌
      (Q: Flow rate, Δ P: pressure difference, ρ: gas density)

  2. Select control mode

    • analog controlSuitable for direct control by PLC

    • Digital CommunicationSuitable for integration into intelligent vacuum management systems

  3. Sealing material

    • Fluororubber (AA)Low cost, suitable for general vacuum (≤ 10 ⁻⁹ mbar)

    • Metal seal (MM)Ultra high vacuum (≤ 10 ⁻¹¹ mbar), plasma resistant

  4. Special Options

    • Heating versionPrevent gas condensation (such as SiH ₄ process)

    • ATEX explosion-proof certification: Used in hazardous environments


6、 Key points for installation and debugging

  • Mechanical Installation

    • The direction of the valve body should be consistent with the airflow (indicated by the arrow)

    • Avoid vibration sources (it is recommended to install shock absorbers)

  • electrical connection

    • Shielded cable wiring (to prevent electromagnetic interference)

    • Grounding resistance<1 Ω

  • parameter calibration

    1. Set the zero position (0% opening) through HMI or software

    2. Calibrate the full range (100% opening corresponds to 10V/20mA)

    3. Test step response (target: overshoot<5%)


7、 Typical fault handling

fault phenomenon Possible reasons solution
Valve opening jitter Signal interference/unstable power supply Check the shielding grounding and stabilize the power supply
Pressure control overshoot PID parameters are unreasonable 重新整定(P↓, I↑, D↓)
Communication interruption Protocol configuration error Verify baud rate/device address

Swiss VAT 590 series electric high fidelity air conditioning valve