- Phone
-
Address
11th Floor, No. 3, No. 525 Yuanjiang Road, Minhang District, Shanghai
Shanghai Xieshuo Instrument Technology Co., Ltd
11th Floor, No. 3, No. 525 Yuanjiang Road, Minhang District, Shanghai
Innovative Optical Systems“excellentPerfect Zoom System*Sex provides a magnification ratio of 25:1 (with a magnification range of 0.63x-15.75x). even if
Using a 1x objective lens, SMZ25 can also capture the entire 35mm culture dish while presenting microscopic details.
StereomicroscopeBreaking through traditional design,excellentThe zoom system will automatically change the distance between the two optical axes as the zoom coefficient changes. The variation in optical axis distance results in the maximum amount of light entering the optical path at different magnification coefficients, allowing observers to obtain clearer and brighter images with minimal aberration effects. In addition, this groundbreaking optical design concentrates all these ideal functions in a compact zoom body, also realizing the ergonomic instrument design concept.
The SHR flat field apochromatic series objective provides a high resolution of 1100LP/mm (observed using the maximum zoom ratio of the SHR flat field apochromatic 2X objective) and vivid images with realistic colors.
Seamless switching between whole organism imaging and high magnification local detail imaging.
The SMZ25 series uses compound eye lenses on epifluorescence attachmentsStereomicroscopeThis innovative design ensures bright and uniform illumination even at low magnification, thus achieving a wide field of viewexcellentUniformity of brightness.
Nikon's newly developed optical system can significantly improve the signal-to-noise ratio even at high magnification, making it possible to capture cell division, which is difficult to achieve through traditional methodsStereomicroscopeachieve.
Nikon has successfully optimized the fluorescence image signal and reduced noise in the image by using short wavelength, high transmittance lenses. SMZ18/25 combined with innovative epifluorescence attachment, has higher fluorescence than traditional onesStereomicroscopeBetter fluorescence detection capability.
By using the Digital Sight digital camera and NIS Elements analysis software, or the Digital Sight digital camera and DS-L4, as well as a microscope, the required information such as Z-axis driver position, zoom factor, objective lens, filter block, and transmitted light brightness can be easily obtained.
Software applicable to all systems: NIS Elements is Nikon's flagship imaging software, compatible with Nikon's latestStereomicroscopeThe SMZ25 and SMZ18 systems are used in conjunction. NIS Elements can achieve a wide range of advanced digital imaging functions.
Multiple fluorescence channels can be captured by combining other imaging methods such as OCC or bright field
The new LED transmission base with built-in OCC lighting has the characteristics of low heat generation, extremely low power consumption, and long service life. Using this lighting can enhance the contrast of specimens, such as surface observation of embryos.