The ship exhaust gas cleaning water quality monitoring system consists of sensor cabinets, electronic units, air purification systems, integrated circulation pumps, pressure reducing valves, and flow meters. It is used to monitor the seawater quality at the inlet and outlet, obtain water quality monitoring data to determine whether the discharged water meets the standards. The sensor cabinet can monitor parameters including polycyclic aromatic hydrocarbons (PAH), turbidity, temperature, and pH, and the data is transmitted to the central control system through Ethernet connection. The UviLux fluorescence sensor is configured in the system to meet special requirements for PAH and turbidity monitoring, with turbidity measurement complying with the ISO7027:1999 international standard.
Instrument features
Continuous real-time monitoring of imported and discharged water quality;
Declaration in compliance with the regulations of the Marine Environment Protection Committee (MEPC);
• Used for monitoring polycyclic aromatic hydrocarbons (PAHs), turbidity, temperature, and pH;
PAH fluorescence meter automatically corrects turbidity, UV absorbance, and temperature;
The data is transmitted to the central control system through Ethernet connection and 4-20 mA analog output;
Flexible configuration suitable for old ship renovation and new ship construction;
Suitable for monitoring freshwater and seawater;
Application
• Used to monitor the water quality of the inlet and outlet of the ship's exhaust gas cleaning system, ensuring that emissions meet standards;
The system can be used for new ship construction and old ship renovation;
Technical parameters
• Size: 1300 (H) x 600 (W) x 300 (D) mm;
Universal power supply: 85-264VAC, 45-65Hz or 90-350VAC;
• Maximum operating pressure: 4.0 bar;
• 操作温度: 0 ºC~ 50ºC;
Sample flow rate: 3-40 L/min;
• PAH measurement range: 0-4500 ug/l;
• PAH measurement sensitivity: 0.04ug/l;
• Turbidity measurement range: 0-1000 FNU;
• Turbidity measurement sensitivity: 0.01 FNU (compliant with ISO7027:1999 standard);
• pH measurement range: 0-14 pH;
• pH measurement sensitivity: ± 0.01pH;
• Temperature measurement range: 0-50 º C;
Temperature measurement accuracy: ± 0.1 º C;
• Absorption measurement range: 0-3.5cm-1;
• Sensitivity of absorbance measurement: 0.002cm-1;
System output: Modbus TCP/IP (RJ45) and 4-20 mA analog output;
• Display/User Interface: Projected capacitive and 1280 x 800 resolution touch screen;
Sample import/export flange: DIN32, PN10 (replaceable according to required size);
Cabinet configuration: sensor streamline and electronic casing;