- Phone
-
Address
No. 14 Baifeng Road, Lianghu Industrial Park, Shangyu District, Shaoxing City, Zhejiang Province
Shaoxing Shangyu Shangfan Co., Ltd
No. 14 Baifeng Road, Lianghu Industrial Park, Shangyu District, Shaoxing City, Zhejiang Province
Shangyu Axial Flow Fan Low Noise Smoke Exhaust Fan
(1) Technical performance:
The T35-11 axial flow fan is an efficient low-pressure ventilation fan promoted and used by the Vertical Mechanism Committee. It has low power consumption, low noise, and excellent corrosion resistance. Can be used as industrial plants, machinery manufacturing, chemical industry, printing and dyeing, electroplating, pharmaceuticals and other industries; Cinemas, hotels, office buildings, various residential buildings, etc. If the fan casing is removed, it can also be used as an electric fan or installed in series at intervals in longer exhaust ducts to increase the total pressure in the ducts.
(2) Type of fan:
T35 axial flow fans are classified according to the size of the impeller diameter NO2.8、NO3.15、NO3.55、NO4、NO4.5、NO5、NO5.6、NO6.3、NO7.1、NO8、NO9、NO10、NO11.2 Thirteen machine numbers, each with four blades. The blades can be installed at five angles: 15 °, 20 °, 30 °, and 35 °. Therefore, due to the size of the blade installation angle, the speed of the spindle, the wind pressure, air volume, and power consumption of the fan vary for each machine number.
Transmission method: Various levels of electric motors are selected, directly connected to the impeller, and the body shell is made into a cylindrical shape with a clockwise rotation direction.
3、 Maintenance of Axial Flow Fans
1. Before installation, the ventilation fan should be thoroughly inspected for any damage or deformation caused by packaging or transportation, and can only be installed after proper repair. During installation, attention should be paid to checking whether the related parts are loose, and the gap between the blades and the air duct should be uniform and not collide.
2. The weight of the pipeline connecting the air outlet should not be borne by the fan duct, and additional support should be added during installation.
3. A collector must be installed at the inlet end of the axial flow fan, and a protective wire mesh must be installed.
4. The fan base must be naturally connected to the foundation plane, and bolts must not be forced to connect to prevent deformation of the base. During installation, use a spirit level to calibrate the machine base, add padding to maintain its horizontal position, and then tighten the anchor bolts.
5. The axial flow fan is not allowed to be lifted for use. After installation, a trial run must be conducted first.
6. When reusing a ventilation fan after a long period of disuse, it is necessary to first check whether the connecting parts are firm and reliable, and conduct a trial operation before it can be officially used.
7. After the fan is officially put into operation, it should be checked once a year to see if the screws are loose and if the wire surface is damaged, and repaired according to its specific situation.
8. Regularly pay attention to whether there is any abnormal noise or increased vibration during the operation of the fan, and promptly inspect and repair it.
The company is committed to pursuing: people-oriented, focusing on quality; Putting precision first and emphasizing high quality; Honesty is the key, emphasizing quality; High standards and emphasis on practicality The spirit of quality enterprise. In the fierce market competition, it is our responsibility to revitalize the national industry, with reputation as the foundation, and we will continue to be dedicated Products and services provided to a wide range of users.
Fiberglass Axial Flow Fan - Axial Flow Fan Manufacturer
Shangyu Axial Flow Fan Low Noise Smoke Exhaust Fan
This series of products consists of explosion-proof motors, blades, air ducts, etc. The blades are made of aluminum plates, and the air ducts are processed and welded from steel plates and profiles. The power leads can be wired with steel pipes or cables, and there are grounding screws outside the shell. Product features
1. Explosion proof axial fan is composed of explosion-proof motor, blades, air duct and other components.
2. The fan is made of high-quality rolled steel plates and has high strength.
3. The motor has reliable performance, low energy consumption, and long lifespan.
2. Cable routing.
axial flowfanIt has a very wide range of applications, which refers to the airflow in the same direction as the axis of the fan blades, such as electric fans and air conditioning outdoor fans that operate in axial flow mode. Why it is called'Axial flow type'It is because the gas flows parallel to the axis of the fan. Axial flow fans are usually used in situations where flow requirements are high but pressure requirements are low. Axial flow fan is fixed in position and moves the air. Axial flow fans are mainly composed of fan impellers and casings, with a simple structure but very high data requirements.