- Phone
-
Address
No. 99 Furong 3rd Road, Xishan Economic Development Zone, Wuxi City, Jiangsu Province, China
Wuxi Senar Instrument Equipment Manufacturing Co., Ltd
No. 99 Furong 3rd Road, Xishan Economic Development Zone, Wuxi City, Jiangsu Province, China
1、 Product Features
1) The new generation of integrated one-way valves avoids interference from static electricity and high viscosity solvents
2) Double plunger reciprocating series pump design, optional parallel pump, improves system pressure resistance and analysis accuracy
3) The sample tray is temperature controlled to ensure sample stability and improve the accuracy of analysis results
4) The Peltier temperature control method can quickly respond to temperature changes, provide real-time temperature adjustment, and offer high-precision temperature control
5) The speed of the circulating fan is adjustable and monitored in real-time, ensuring the uniformity and stability of the internal temperature of the column temperature box.
6) The side mounted light source allows users to perform daily maintenance on their own, such as replacing the light source without disassembling other parts of the detector
7) Having good compliance, recording the duration of light source usage for easy tracking and maintenance
2、 Specifications
1) Operating pressure upper limit: 9600psi (optional 11600psi), can set upper and lower limits, can automatically alarm and stop the pump
2) Binary high-pressure infusion pump and quaternary low-pressure infusion pump can be optionally equipped with or upgraded with automatic emptying system and automatic built-in online degassing system (up to 6 channels), which can automatically open or close the emptying valve when emptying the infusion pump
3) Flow precision: ≤ 0.06% (1.000mL/min under specific conditions)
4) Drawer style dual sample tray design, compatible with different capacity sample bottles for simultaneous analysis
5) Injection volume: 0.0-100.0 μ L (supports customization of other volumes, up to 4500 μ L)
6) Injection modes: full loop injection, partial injection, and non-destructive injection can be set
7) Sample residue: ≤ 0.0005% (caffeine), detection wavelength 273nm
8) The standard injection sequence can automatically shut down after running
9) Temperature control method: Peltier temperature control method or forced air circulation temperature control method
10) Temperature control range (℃): 5 ℃~85 ℃ or 10 ℃~110 ℃
11) Column capacity: can accommodate 4 25cm chromatography columns or 4 30cm chromatography columns
12) Detector options: UV visible detector, diode array detector, evaporative light scattering detector, differential refractive index detector, fluorescence detector
13) Solvent storage: The solvent organizer can accommodate 4 types of mobile phase solvents, 1 type of needle washing solvent, and 1 type of infusion pump cleaning solvent