S070 series small direct acting three-way solenoid valve direct piping type:7mm wide small solenoid valve cartridgeValve unit mass: 5 g● Containerized model: SS073● Single unit specifications, bottom plate piping container type, direct piping container type optional● Containerized model: SS073
• Power consumption of 0.35W (standard type) and 0.1W (with energy-saving circuit type) • Action noise below 38dB (A) • Sound velocity and conductivity C: 0.060mm3/(s • bar)] • Comes with a combination type assembly board
Note 1) For low-temperature use, use dry air to prevent condensation.
Note 2) Vibration resistance: Vibration tests were conducted along the axial direction of the moving iron core and perpendicular to the axial direction, under various conditions of electrification and non electrification, within the frequency range of 45~2000Hz, and no misoperation was observed. (Initial value) Impact resistance: On a drop type impact testing machine, conduct one test each along the axial direction of the moving iron core and perpendicular to the axial direction, under both powered and unpowered conditions, and ensure no misoperation.
(Initial value) Note 3: Under low vacuum specifications, the operating pressure range is 1.33 × 102Pa to the highest operating pressure.
Installation and removal methods of valves: 1) When using the bottom plate piping type and screw fixing type, it is necessary to confirm the installation status of the gasket installed at the interface of the body, and then tighten the special installation screw (AXT632-106-1) with an appropriate torque (0.10~0.14N · m). (Tighten the valve evenly without tilting)
2) Installation history of bottom plate piping type and clamping type. Use a straight clock screwdriver or other tool to insert into the hole of the installation part q, and pull out about 1mm in the direction of the arrow. Insert the solenoid valve into the joint surface from above w, confirm that the bottom surface of the solenoid valve contacts the top surface of the assembly board, and when holding down the solenoid valve body, remove the straight clock screwdriver from the installation part. Before installation, it is necessary to confirm that the gasket on the joint surface of the solenoid valve body is in the installation state. The plate spring installed inside restores the installation part to its original position. (Then confirm that the end of the installation part is aligned with the side of the container block, as shown in the figure below) Similarly, when removing the valve, pull open the installation bracket and vertically remove the solenoid valve. Be careful not to apply excessive force to the wires during installation and disassembly.