Welcome Customer !

Membership

Help

Guangdong Guangce Instrument Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Rotorless rheometer

NegotiableUpdate on 01/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The rotorless rheometer is an instrument widely used in the rubber processing industry for controlling rubber quality, rapid inspection, and basic rubber research. It provides accurate data for rubber formula combinations and can accurately measure parameters such as scorch time, vulcanizing time, vulcanization index, and maximum and minimum torque.
Product Details

Rotorless rheometer

Model:GC-6001



1Equipment Overview:Rotorless vulcanizing instrument is a widely used instrument in the rubber processing industry for controlling rubber quality, rapid inspection, and basic research on rubber. It provides accurate data for rubber formula combinations and can accurately measure parameters such as scorch time, positive vulcanizing instrument time, vulcanization index, and maximum and minimum torque.

IImainfeature:

1The rotorless vulcanizing instrument adopts the latest version of domestic software, which has fast temperature rise(3The characteristics of high temperature control accuracy within minutes.

2The rotorless vulcanizer adopts an alpha sealed mold cavity structure.

3The rotorless vulcanizing instrument adopts the Alpha force sensor technology of *(Sensor accuracy reaches0.001N.m)

4Rotorless vulcanizing apparatuspickUsing the alpha sealed cavity structure of *, the rotating cavity and fixed cavity are sealed by an imported sealing ring. Moreover, the structure of the sealed cavity is different from that of the general open cavity, and its accuracy, requirements, and * performance cannot be compared. The repeatability of the closed mold cavity is almost consistent, and the testing accuracy is high.

IIIworking principle

Place the rubber sample into a sealed mold cavityAnd kept at the test temperature, the mold cavity has two parts, the upper and lower parts, with the lower part moving back and forth in a small linear motion (oscillation), which causes the sample to produce shear strain. The reaction torque (force) of the sample on the mold cavity is measured, and the magnitude of this torque (force) depends on the shear modulus of the rubber material.
After the vulcanization test begins, the shear modulus of the sample increasesThe computer displays and records the torque (force) in real time. When the torque (force) rises to a stable or maximum value or even returns to a state, a relationship curve between torque (force) and time is obtained, namely the vulcanization curve (as shown in Figure 1). The shape of the curve is related to the temperature of the test and the characteristics of the rubber material.

4Meet the standards:

Rotorless rheometerMeets the requirements of GB/T16584 "Rubber - Determination of vulcanization characteristics using a rotorless vulcanizing apparatus", ISO6502, and Italian standardsT/10、T/30、T/50、T/60、T/90data ASTM-D5289、ISO-6502.

5Application industry:

It is a national regulationDeveloping new products and researching rubber formulaControl the quality of the adhesive materialandThe Most Applied Basic Research on RubberImportant testing instruments.Widely applicable to various industries of rubber products.

6、 Technical parameters:

type number

GC-6001B

Temperature control range

room temperature—200℃

Temperature fluctuation range

±0.15℃

Torque resolution

1/500000

Torque accuracy

0.3%

Torque unit

N.m、N.cm、N.inch、kN.m、kN.cm、kN.inch、kg.m、kg.cm、kg.inch、lp.m、lp.cm、lp.inch、g.m、g.cm、g.inch

Temperature display resolution

0.01℃

Temperature recovery time after mold closure

< 1.5min

temperature unit

C (Celsius), F (Fahrenheit), K (Kelvin)

Collection rate

200 times/s

Supported languages

English, Simplified Chinese, Traditional Chinese.

Usage standard

GB/T 16584、ASTM D5289、ISO 6502

calculation parameters

ts1、ts2、t10、t30、t50、t70、t90、Vc1、Vc2

software interface

USB2.0

print content

Date, time, temperature, vulcanization curve, temperature curveML、MH、ts1、ts2、t10、t50、t90、Vc1、Vc2

Test Standard

comply withASTM D 5289, ISO6502

oscillation frequency

per minute100 cycles (1.67Hz)

Oscillation amplitude

Standard configuration: ± 1 degree ± 0.03 degrees

[Optional]± 0.5 degrees ± 0.03 degrees, ± 3 degrees ± 0.03 degrees

Variable temperature time

170 ℃ → 190 ℃ within 55 seconds at ± 0.3 ℃

190 ℃ → 170 ℃, reaching and within ± 0.3 ℃ within 1 minute and 40 seconds

Temperature recovery time after film lamination

Temperature compensation reply toThe set temperature of 170 ℃ (with an error within ± 0.3 ℃) shall not exceed 30 ± 3 seconds

heating rate

room temperatureArrive at 170 ℃ within 2 minutes and 40 seconds and remain at ± 0.3 ℃

power supply

Compressed air source

220VAC±10%, 50±3Hz;

minimumminimum 65psi (4.5kg/cm2)customer-supplied

size

L65cm x W59cmx H148cm

weight

gross weightGross: 300kg , Net weight: 250kg

Configuration List

Configuration List

nameName

quantityQuantity

brand Brand

Place of OriginOrigin

Whole machine shell

1set

定制

Dongguan

Host storage cabinet

1set

定制

Dongguan

Vulcanizer motherboard

1set

GC-5.5

Dongguan

ACmotor

1Taiwan

Speed regulating motor

domestic

software

1set

定制

Dongguan

torque sensor

1set

定制

Dongguan

cylinder

1set

Shandong Naisi Pneumatic

Zhejiang

Open mold cavity

up and down

定制

Dongguan

Acrylic protective cover

1set

定制

Dongguan

oil-water separator

1set

定制

Dongguan

solenoid valve

1set

Gangtian Pneumatic

Dongguan

temperature sensor

2a

PT-1000

Import

Heating element

2a

定制

Dongguan

exhaust fan

1set

Green Island Wind

Guangdong

filter

1set

定制

domestic

wire

several

The Pearl River Cable

Guangzhou