Radeagle Manual RADEAGLE is a handheld radioactive isotope identifier (RIID) that has recognition speed and accuracy.
Main customers and applications
Intelligent Algorithm - Speed and Accuracy
RADEAGLE's algorithm is unparalleled, as it uses neural networks to create multi-agent systems. The multi-agent system in turn uses learning algorithms to adapt the reference data to the characteristics of the detector sensor. While continuously measuring background radiation, this' neural spectrum brain 'can provide speed and accuracy to detect and identify over 67 nuclides, far exceeding the requirements specified in ANSI 42.34.
Operation Mode
RADEAGLE has five basic operating modes: dose rate, detection, simple recognition, spectral measurement, and advanced mode. These five simple modes provide users with comprehensive system control, ranging from fast and accurate recognition to extensive spectral analysis and expert system configuration.
Application centric approach
One major advantage of the RADEAGLE algorithm is that it can be optimized for multiple practical applications. Through extensive simulation, validation, and improvement of real-world experience, the performance of RADEAGLE has been adjusted and optimized for key isotopes related to SNMs in the nuclear safety and security market, NORM and IND for environmental and industrial applications, and MED for nuclear medicine. The waterproof NaI model also supports underwater measurement.
RADEAGLE AQUA
| Energy Range/MCA | 11 keV to 3 MeV/2048 channels |
| Calibration source | Natural background, optional embedded calibration source. |
| Nuclide library | Default isotope: 110mAg,241Am,133Ba,207Bi,109Cd,252Cf (requires neutron detection),57Co,60Co,51Cr,134Cs,137Cs,152Eu,68Ga,123I,125I,131I,111In,40K,54Mn,99Mo2,22Na,237Np,238Pu,239Pu, (240Pu,241Pu as part of compositions)226Ra,75Se,99mTc,232Th,201Tl,233U,235U,238U Optional isotopes (contact factory): 109mAg,198Au,135mBa,140Ba,213Bi,116Cd,58Co,139Ce,141Ce,144Ce,131Cs,64Cu,67Cu,165Dy,18F,59Fe,67Ga,68Ge,166mHo,124I,132I,133I,194Ir,42K,81mKr,138La,140La,173Lu,174Lu,176Lu,177Lu,177mLu,56Mn,24Na,95Nb,96Nb,147Nd,212Pb,103Pd,144Pr,82Rb,186Re,188Re,106Rh,103Ru,106Ru,153Sm,113Sn,82Sr,89Sr,90Sr,132Te,228Th,44Ti,202Tl,204Tl,232U,237U,187W,131mXe,133Xe,133mXe,135Xe,88Y,90Y,169Yb,177Yb,65Zn,95Zr |
| Nuclide category | Special Nuclear Materials (SNMs), Natural Radioactive Materials (NORMs), Industrial Nuclides (IND), or Medical Sources (MEDs) |
| size | 248mm x 115mm x 152mm (9.8 inches x 4.5 inches x 6.0 inches) |
| display | 640 x 480, 89 mm (3.5 inches) semi reflective color TFT |
| battery | Rechargeable AA nickel hydrogen battery pack, AA nickel hydrogen or alkaline auxiliary battery box |
| Operation running time | Standard battery pack>8 hours |
| Operating Temperature | -20 ° C to+50 ° C (-4 ° F to+122 ° F) |
| relative humidity | 10% -90%, no condensation |
| protection level | IP65, For 3SGA and 3SGA-H models, diving up to 15 meters is allowed |
| memory | >16 GB (1000000 spectra) |
| CPU speed | 1 GHz |
| file format | ANSI N42.42, SPE (IAEA) |
| connection | USB, WiFi, GPS (optional) |
| operating system | Microsoft Windows (XP, Vista, 7, 8, 10), MAC OS X Yosemite, Linux (tested on Ubuntu) |
| model | detector type | Detector size | PMT | GM | He3 | Resolution at ambient room temperature @ 662 keV137Cs at ambient room temp | Sensitivity cps/µ Sv/h @ 662 keV137Cs | Detector dose rate rangeµSv/h | GM dose rate range, up to Sv/h | Weight (g) |
| RADEAGLE-3SG | NaI(Tl) | 76.2x25.4 millimeters (3x1 inches) | 3 inches | x |
| ≤7.2% | >2500 | 0.01–200 | 1 | ~2620 |
| RADEAGLE-3SG-H | NaI(Tl) | 76.2x25.4 millimeters (3x1 inches) | 3” | x | x | ≤7.2% | >2500 | 0.01–200 | 1 | ~2720 |
| RADEAGLE-3SGA | NaI(Tl) | 76.2x25.4 millimeters (3x1 inches) | 3 inches | x |
| ≤7.2% | >2500 | 0.01–200 | 1 | ~2620 |
| RADEAGLE-3SGA-H | NaI(Tl) | 76.2x25.4 millimeters (3x1 inches) | 3 inches | x | x | ≤7.2% | >2500 | 0.01–200 | 1 | ~2720 |
| RADEAGLE-2CG | CeBr3 | 50.8x25.4 millimeters (2x1 inches) | 3 inches | x |
| ≤4.0% | >1600 | 0.01–300 | 1 | ~2200 |
| RADEAGLE-2CG-H | CeBr3 | 50.8x25.4 millimeters (2x1 inches) | 3 inches | x | x | ≤4.0% | >1600 | 0.01–300 | 1 | ~2620 |
| RADEAGLE-3CG | CeBr3 | 76.2x20.3 millimeters (3x0.8 inches) | 3 inches | x |
| ≤4.0% | >2500 | 0.01–200 | 1 | ~2620 |
| RADEAGLE-3CG-H | CeBr3 | 76.2x20.3 millimeters (3x0.8 inches) | 3 inches | x | x | ≤4.0% | >2500 | 0.01–200 | 1 | ~2720 |
| RADEAGLE-2LG | LaBr3(Ce) | 50.8x25.4 millimeters (2x1 inches) | 3 inches; | x |
| ≤3.0% | >1600 | 0.01–300 | 1 | ~2250 |
| RADEAGLE-2LG-H | LaBr3(Ce) | 50.8x25.4 millimeters (2x1 inches) | 3 inches | x | x | ≤3.0% | >1600 | 0.01–300 | 1 | ~2250 |
| model | description |
| RADEAGLE-3SG | belt3x1 NaI(Tl)Detector andGMGamma handheld tubeRIID. |
|
RADEAGLE-3SG-ES | Gamma handheld RIID with 3x1 NaI (Tl) detector and GM tube. Built in scale source. |
| RADEAGLE-3SG-GPS | belt3x1 NaI(Tl)DetectorGMGuan andGPSGamma handheldRIID. |
| RADEAGLE-3SG-GPS-ES | Gamma handheld RIID with 3x1 NaI (Tl) detector, GM tube, and GPS. Built in scale source. |
| RADEAGLE-3SG-H | belt3x1 NaI(Tl)DetectorGMGuan andHe-3Gamma of detector/Neutron handheldRIID. |
|
RADEAGLE-3SG-H-ES | Gamma/Neutron Handheld RIID with 3x1 NaI (Tl) detector, GM tube, and He-3 detector. Built in scale source. |
| RADEAGLE-3SG-H-GPS | belt3x1 NaI(Tl)DetectorGMManagementHe-3Detector andGPSThe Gamma/Neutron handheldRIID. |
| RADEAGLE-3SG-H-GPS-ES | Gamma/Neutron Handheld RIID with 3x1 NaI (Tl) detector, GM tube, He-3 detector, and GPS. Built in scale source. |
| RADEAGLE-3SGA | belt3x1 NaI(Tl)DetectorGMGamma handheld tube and underwater optionsRIID. |
| RADEAGLE-3SGA-ES | Gamma handheld RIID with 3x1 NaI (Tl) detector, GM tube, and underwater options. Built in scale source. |
| RADEAGLE-3SGA-GPS | belt3x1 NaI(Tl)DetectorGMPipes, underwater options, andGPSGamma handheldRIID. |
| RADEAGLE-3SGA-GPS-ES | Gamma handheld RIID with 3x1 NaI (Tl) detector, GM tube, underwater options, and GPS. Built in scale source. |
| RADEAGLE-3SGA-H | belt3x1 NaI(Tl)DetectorGMManagementHe-3Gamma detectors and underwater options/Neutron handheldRIID. |
| RADEAGLE-3SGA-H-ES | Gamma/Neutron Handheld RIID with 3x1 NaI (Tl) detector, GM tube, He-3 detector, and underwater options. Built in scale source. |
| RADEAGLE-3SGA-H-GPS | belt3x1 NaI(Tl)DetectorGMManagementHe-3Detector, underwater options, andGPSThe Gamma/Neutron handheldRIID. |
| RADEAGLE-3SGA-H-GPS-ES | Gamma/Neutron Handheld RIID with 3x1 NaI (Tl) detector, GM tube, He-3 detector, underwater options, and GPS. Built in scale source. |
| RADEAGLE-2CG | belt2x1 CeBr3Detector andGMGamma handheld tubeRIID. |
| RADEAGLE-2CG-ES | Gamma handheld RIID with 2x1 CeBr3 detector and GM tube. Built in scale source. |
| RADEAGLE-2CG-GPS | belt2x1 CeBr3DetectorGMGuan andGPSGamma handheldRIID. |
| RADEAGLE-2CG-GPS-ES | Gamma handheld RIID with 2x1 CeBr3 detector, GM tube, and GPS. Built in scale source. |
| RADEAGLE-2CG-H | belt2x1 CeBr3DetectorGMGuan andHe-3Gamma of detector/Neutron handheldRIID. |
| RADEAGLE-2CG-H-ES | Gamma/neutron handheld RIID with 2x1 CeBr3 detector, GM tube, and He-3 detector. Built in scale source. |
| RADEAGLE-2CG-H-GPS | belt2x1 CeBr3DetectorGMManagementHe-3Detector andGPSThe Gamma/Neutron handheldRIID. |
| RADEAGLE-2CG-H-GPS-ES | Gamma/Neutron Handheld RIID with 2x1 CeBr3 detector, GM tube, He-3 detector, and GPS. Built in scale source. |
| RADEAGLE-3CG | belt3x0.8 CeBr3Detector andGMGamma handheld tubeRIID. |
| RADEAGLE-3CG-ES | Gamma handheld RIID with 3x0.8 CeBr3 detector and GM tube. Built in scale source. |
| RADEAGLE-3CG-GPS | belt3x0.8 CeBr3DetectorGMGuan andGPSGamma handheldRIID. |
| RADEAGLE-3CG-GPS-ES | Gamma handheld RIID with 3x0.8 CeBr3 detector, GM tube, and GPS. Built in scale source. |
| RADEAGLE-3CG-H | belt3x0.8 CeBr3DetectorGMGuan andHe-3Gamma of detector/Neutron handheldRIID. |
| RADEAGLE-3CG-H-ES | Gamma/neutron handheld RIID with 3x0.8 CeBr3 detector, GM tube, and He-3 detector. Built in scale source. |
| RADEAGLE-3CG-H-GPS | belt3x0.8 CeBr3DetectorGMManagementHe-3Detector andGPSThe Gamma/Neutron handheldRIID. |
| RADEAGLE-3CG-H-GPS-ES | Gamma/Neutron Handheld RIID with 3x0.8 CeBr3 detector, GM tube, He-3 detector, and GPS. Built in scale source. |
| RADEAGLE-2LG | belt2x1 LaBr3(Ce)Detector andGMGamma handheld tubeRIID. |
| RADEAGLE-2LG-GPS | belt2x1 LaBr3(Ce)DetectorGMGuan andGPSGamma handheldRIID. |
| RADEAGLE-2LG-H | belt2x1 LaBr3(Ce)DetectorGMGuan andHe-3Gamma of detector/Neutron handheldRIID. |
| RADEAGLE-2LG-H-GPS | belt2x1 LaBr3(Ce)DetectorGMManagementHe-3Detector andGPSThe Gamma/Neutron handheldRIID. |
| Attachment |
|
| RE-AP009-1 | Battery pack with battery (backup) |
| RE-AP009-2 | Battery pack without battery (battery holder) |
| RE-CA019 | Automatic power adapter,12 V |
| RE-CC022 | suitcase |
| RE-CM020 | Charger module |
| RE-HB021 | Portable leather case with belt |