Price of relay protection tester

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The price of L8831 relay protection tester is adjusted by the voltage regulator to output AC0-250V, and after rectification and filtering, it outputs 0-300V DC (which can be selected for monitoring through the monitoring selection switch). It can be used in conjunction with the main circuit to complete various relay verifications that require two-way coordination (such as reclosing). There is also a DC5V output for the internal electrical stopwatch and digital meter head.

Product Details

L8831Price of relay protection testerThere is a standard six phase current and six phase voltage output simultaneously, with a current of 30A/phase and a voltage of 125V/phase. Six phase current parallel connection can reach 180A. It can be used to test various traditional relays and protection devices, as well as various modern microcomputer protections, especially for transformer differential protection and backup automatic switching devices, making testing more convenient.

Main technical indicators:

1. Rated input: AC220V ± 10% 50HZ 1KVA

2. Rated output:

(1) Main circuit AC0-250V DC0-300V AC0-20A AC0-100A

(2) Auxiliary circuit DC0~300V AC~250V

3. Measurement range

(1) Current 0-20A 0-200A DC0-20A

(2) Voltage AC0-1000V DC0-1000V

(3) Time from 00.01 to 99.99 seconds

4. It has a contact connection buzzer prompt function, which is convenient for monitoring the on/off status of the contacts.

Working Principle:

1. The working principle and various performance indicators are described below.

2. Principle explanation: The whole machine is composed of a main circuit and an auxiliary circuit, with different measurements and controls.

(1) Main circuit:

The input AC220V is regulated by a voltage regulator, isolated by a transformer (also serving as an inverter), with a high voltage output of AC0-250V. After rectification and filtering, it outputs DC0-300V DC. Low voltage high current output of 100A and transmission of 20A. 20A has strong load capacity and can operate at full load for a long time.

The measurement of AC and DC currents adopts a new type of current sensor with an accuracy of better than 0.5%. After sampling by the current sensor, the differential amplification is sent to the digital meter for display, and the decimal points of 100A and 20A are automatically converted.

The voltage measurement has a digital meter head on the upper part of the instrument, which can select the monitored output voltage through the monitoring selection switch, basically meeting the testing requirements.

(2) Auxiliary circuit

The L8831 relay protection tester outputs AC0-250V through voltage regulator auxiliary adjustment, and outputs 0-300V DC after rectification and filtering. (Monitoring can be selected through the monitoring selection switch) It can be used in conjunction with the main circuit to complete various relay verifications that require two-way coordination (such as reclosing). There is also a DC5V output for the internal electrical stopwatch and digital meter head.

L8831Price of relay protection testerPerformance characteristics:

The main and auxiliary AC and DC outputs do not interfere with each other.

Comprehensive monitoring of DCV, DCA, ACV, ACA.

◆ It has a contact connection buzzer prompt function.

All digital displays are convenient for night use.

The aluminum alloy shell is compact, portable, and easy to carry.