Price of oil immersed test transformer

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The price of the 20kVA oil immersed test transformer is a basic testing equipment used by power plants, power supply bureaus, and research institutions for conducting AC withstand voltage tests. It has passed the standards of the National Quality Supervision Administration and is used for insulation strength tests of various electrical products, electrical components, insulation materials, etc. under specified voltages.

Product Details

Product Overview:
  20kVAPrice of oil immersed test transformerThe product is a basic testing equipment used by users such as power plants, power supply bureaus, and scientific research institutions to conduct AC withstand voltage tests. It has passed the standards of the National Quality Supervision Administration and is used to conduct insulation strength tests on various electrical products, electrical components, insulation materials, etc. under specified voltages to assess the insulation level of the product, discover insulation defects of the tested product, and measure the ability to withstand overvoltage.
Features:
★ Fine Voltage Adjustment Mode
★ Three operation modes: industrial computer, microcontroller, and manual electronic control
★ Three display systems including computer screen, LCD Chinese display, and pointer meter
★ Suitable for various purposes such as withstand voltage, rapid breakdown, and power frequency electrical strength
★ Virtual instrument technology, computer control, new technology, high-end
★ Full Chinese color screen, fully mouse operated, with no operational barriers
★ Can automatically test multiple voltages or single voltage
★ Real time dynamic test curve, dual data comparison on the same screen, convenient for fault analysis
Technical Indicators:
1. Rated capacity: 1-300KVA
2. Single rated output voltage:
(AC) 50、100、150、200、300KV
(DC) 70、140、210、280KV
3. Rated input voltage: 200V, 400V
4. Transformation ratio: 500/1, 1000/1, 1500/1, 2000/1, 3000/1
5. Ratio error: ≤± 1.5%
6. Impedance voltage:<10%
  20kVAPrice of oil immersed test transformerMain purpose:
1. AC voltage withstand test of 6kV-500kV high-voltage cross-linked cable
2. Power frequency withstand voltage test of 6kV-500kV transformer
3. AC withstand voltage test for GIS and SF6 switches
4. AC voltage withstand test of generator
5. AC withstand voltage test for other high-voltage electrical equipment such as busbars, bushings, and transformers.
Precautions for operation:
1. Test personnel should divide responsibilities, set a safe distance at the test site, carefully inspect the grounding of the test sample and test transformer, and assign a dedicated person to monitor safety and observe the status of the test sample.
2. Before conducting the experiment on the test sample, all external connections should be removed and fully discharged. The main parts should be cleaned and kept dry to avoid damaging the test sample and causing errors in the test values.
3. For large capacity test samples (capacitors, ultra long cables, etc.), the voltage should be slowly increased to prevent the microampere meter from being burned out due to excessive charging current of the test sample. If necessary, the microampere meter should be read for stable readings at different voltages by gradually increasing the voltage.
4. During the experiment, the test object, microampere meter, and testing device should be closely monitored. In case of flickering, breakdown, or other phenomena, the voltage should be immediately reduced, the power should be cut off, and the cause should be identified.
油浸式试验变压器价格