Welcome Customer !

Membership

Help

Shanghai Jiuheng Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Portable flaw detector

NegotiableUpdate on 01/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The IP rating of the portable flaw detector is based on the IEC 60529-2004 standard (enclosure protection level - IP specification), and the instrument design complies with the intrusion protection rating standards: IP67 (dustproof and capable of short-term immersion in water) and IP65 (dustproof and capable of withstanding water spray).
Product Details
General Specifications Portable flaw detector receiver
Language of user interface English, Spanish, French, German, Japanese, Chinese, Portuguese, Russian, and Italian Maximum input signal 20 Vp
Probe connection LEMO 00 Receiver input impedance 400 Ω±5%
data storage Portable flaw detectorOnboard 100000 ID codes Receiver bandwidth DC ~ 26.5 MHz, At -3 dB (standard configuration)
Battery type and operating time Single lithium-ion battery, rechargeable, standard type; 6 hours of operation time 0.2 MHz ~ 26.5 MHz, At -3 dB (compliant with EN12668 configuration)
Power requirements AC main power supply: 100 VAC~120 VAC, 200 VAC~240 VAC, 50 Hz~60 Hz Digital filter setting 8 digital filter settings (standard configuration)
Display type Full VGA (640 × 480 pixels) transparent color LCD, 60 Hz update rate 7 digital filter settings (compliant with EN12668 configuration)
Display screen size (width x height, diagonal) 117 mm x 89 mm, 146 mm (5.76 inches) detection Full wave, positive half wave, negative half wave, radio frequency wave
External dimensions (width x height x thickness) 209 mm × 128 mm × 36 mm, with a gripping portion of 58 mm System linearity Level: ± 0.5% FSW
weight 890 grams, including lithium-ion battery resolution 0.25% FSH, The amplifier accuracy is ± 1 dB
inhibit 0 ~ 85% FSH, Position increment is 1%
Input/output of the instrument Wave amplitude measurement 1.25% to 110% full screen height
USB port (1) USB 1.1 Full Speed Host Port (Type A) Measurement rate Equivalent to PRF (single pulse emission) in all modes
(1) USB 2.0 full speed customer port (pocket B-type)
video output 1 digital video output pulse generator
pulse generator Adjustable square wave
Environmental rating Pulse repetition frequency (PRF) 10 Hz ~ 2000 Hz, The increment is 10 Hz.
IP rating According to the IEC 60529-2004 standard (enclosure protection level - IP specification), the instrument design complies with the intrusion protection rating standards: IP67 (dustproof and capable of short-term immersion in water) and IP65 (dustproof and capable of withstanding water spray). Energy setting 100 V, 200 V, 300 V, or 400 V
Explosive atmosphere Passed the tests specified in MIL-STD-810F Method 511.4 Procedure I of the US military standard. pulse width Adjustable within the range of 25 ns to 5000 ns (0.1 MHz), utilizing PerfectSquare technology
Impact testing Passed the test specified in MIL-STD-810F method 516.5 procedure I of the US military standard, with 6 cycles per axis, 15 g, and 11 ms half sine wave. damping 50 Ω, 400 Ω
Vibration Test Passed the test in Appendix C, Figure 6 of MIL-STD-810F Method 514.5 Procedure I, with a general exposure of 1 hour per axis.
Operating temperature -10 °C ~ 50 °C
Battery storage temperature 0 °C ~ 50 °C

Shanghai Jiuheng Instrument Co., Ltd. is a professional enterprise engaged in the research and development, production, sales, and service of instruments and meters. Ultrasonic flaw detectors: (EPOCH 600 ultrasonic flaw detector, EPOCH 6LT ultrasonic flaw detector, EPOCH 650 ultrasonic flaw detector, EPOCH 1000 ultrasonic flaw detector, USM 36 ultrasonic flaw detector, USN 60 ultrasonic flaw detector, USM go+ultrasonic flaw detector, Ominskan SX phased array flaw detector, OmniScan MX2 phased array TOFD flaw detector, new OmniScan MX3 fully focused phased array ultrasonic flaw detector); Ultrasonic thickness gauge: (27MG ultrasonic thickness gauge, 45MG ultrasonic thickness gauge, 38DL PLUS ultrasonic thickness gauge, DM5E ultrasonic thickness gauge, CL5 ultrasonic thickness gauge, MAGNA-MIKE 8600 Hall effect thickness gauge, ETG-100 electromagnetic high-temperature thickness gauge); Ultrasonic probe; Customized phased array probe; Eddy current flaw detector: (NORTEC 600 eddy current flaw detector); Hardness tester; DR flat panel detector: 1313 DX ,1515DXT-I ,2520DX ,2530HE,4343HE, Dexela 1207 ,Dexela 1313 ,Dexela 2121S ,Dexela CMOS Flat panel detector, XRD 0822 ,XRD 1611 ,XRD 1621 ,XRD 4343RF ,XRD 3025 ,XRpad 4336 ,XRpad 4343 F ,XRpad2 3025 ,XRpad2 4336。 Endoscopes: (IPLEX NX Olympus Endoscope, IPLEX GX/GT Olympus Endoscope, IPLEX G Lite Olympus Endoscope, IPLEX TX Olympus Endoscope, IPLEX YS Olympus Endoscope, XLGo+Industrial Video Endoscope GE, XL Detect+Industrial Video Endoscope GE New, UVin Professional UV Video Endoscope); Pulse generator: (DRP300 replaces Olympus' 5072PR, 5073PR); Alloy analyzer: (Vanta Olympus handheld alloy analyzer, DELTA Professional handheld alloy analyzer Olympus, DELTA Element handheld alloy analyzer Olympus) and other instruments and meters