Welcome Customer !

Membership

Help

Shanghai Jiuheng Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Portable flaw detector

NegotiableUpdate on 01/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
OmniScan SX portable flaw detector storage device SDHC card, or most standard USB storage devices * digital frequency 100 MHz 100 MHz $r $n * For good results, it is recommended to use Lexar #174; Memory card.
Product Details
shell Dimensions (W x H x D) 267 mm × 208 mm × 94 mm Sound beam formation Scan type Fan shaped or linear
(10.5 in. × 8.2 in. × 3.7 in.) number of groups 1 piece
weight 3.4 kg(7.5 lb), Contains battery data collection PA channel UT channel
Portable flaw detectordata storage Storage device SDHC card, or most standard USB storage devices* Digital frequency 100 MHz 100 MHz
*In order to achieve excellenceAs a result, it is recommended to use Lexar ® Memory card. Maximum pulse rate Up to 6 kHz (C-scan)
Data file capacity 300 MB data processing PA channel UT channel
Portable flaw detectorI/O port USB port 2 USB ports that comply with USB 2.0 technical specifications Number of data points Up to 8192
Audio alarm have Real time average PA: 2、4、8、16 UT: 2、4、8、16、32、64
video output Video Output (SVGA) detection RF, full wave, positive half wave, and negative half wave
I/O line encoder Dual axis encoder line (orthogonal, upward, downward, or clock/direction) filtering 3 low-pass, 3 band-pass, and 5 high pass filters 3 low-pass filters, 6 band-pass filters, and 3 high pass filters (8 low-pass filters in TOFD configuration)
digital input 4 digital TTL inputs, 5V Video filtering Smooth (adjusted according to the frequency range of the probe)
digital output 3 digital TTL outputs, 5 V; each output has a maximum current of 15 mA.
collection switch Yes, it is achieved by configuring a numerical input
Power output line 5 V, 500 mA power output line (with short circuit protection) The data shows A-scan refresh rate A-scan: 60 Hz; S-scan: 60 Hz
Step speed input 5 V TTL pace input data synchronization According to the internal clock 1 Hz~6 kHz
display display size 21.3 cm (8.4 in.) (diagonal) According to the encoder Dual axis: 1 step to 65536 steps
resolution 800 pixels x 600 pixels Programmable Time Correction Gain (TCG) points 16: Each focusing rule has a TCG (Time Correction Gain) curve
brightness 600 cd/m2 Maximum slope 40 dB/10 ns
Observation angle Horizontal: -80 °~80 ° Vertical: -60 °~80 ° call the police alarm count 3 of them
number of colors 16 million condition Any logical combination of gates
type Thin film transistor liquid crystal display (TFT LCD)
power supply Battery Type Intelligent lithium-ion battery
Number of batteries 1 section
Battery power supply time Under normal operating conditions, at least 6 hours
Environmental Technical Specifications Working temperature range -10 °c ~ 45 °C
(14 ºF ~ 113 ºF)
Storage temperature range -20 ° C to 60 ° C (-4 ° F to 140 ° F), including battery
-20 ° C to 70 ° C (-4 ° F to 158 ° F), without battery
relative humidity Under the condition of no condensation at 45 ° C, the maximum relative humidity is 70%.
Intrusion protection rating Designed to meet IP66 rating
Anti collision rating Through the drop test of MIL-STD-810G 516.6
Ultrasonic Technical Specifications (applicable to OMNISX-1664PR) interface 1 phased array interface: Olympus PA interface
2 UT interfaces: LEMO 00
Number of focusing rules 256 pieces
Probe recognition Automatic probe recognition
Pulse generator/receiver aperture 16 chips
Number of chips 64 chips
pulse generator PA channel UT channel
voltage 40 V、80 V、115 V 95 V、175 V、340 V
pulse width Adjustable within the range of 30 ns to 500 ns, with a resolution of 2.5 ns. Adjustable within the range of 30 ns to 1000 ns, with a resolution of 2.5 ns.
Pulse shape Negative square wave Negative square wave
output impedance 35 Ω (pulse echo mode) < 30 Ω
30 Ω (one send one receive mode)
receiver PA channel UT channel
gain 0 dB~80 dB, The maximum input signal is 550 mVp-p (full screen height) 0 dB~120 dB, The maximum input signal is 34.5 Vp-p (full screen height)
input impedance 60 Ω (pulse echo mode) 60 Ω (pulse echo mode)
150 Ω (one send one receive mode) 50 Ω (pulse transmission and reception mode)
System bandwidth 0.6 MHz~18 MHz(–3 dB) 0.25 MHz~28 MHz(–3 dB)

Shanghai Jiuheng Instrument Co., Ltd. is a professional enterprise engaged in the research and development, production, sales, and service of instruments and meters. Ultrasonic flaw detectors: (EPOCH 600 ultrasonic flaw detector, EPOCH 6LT ultrasonic flaw detector, EPOCH 650 ultrasonic flaw detector, EPOCH 1000 ultrasonic flaw detector, USM 36 ultrasonic flaw detector, USN 60 ultrasonic flaw detector, USM go+ultrasonic flaw detector, Ominskan SX phased array flaw detector, OmniScan MX2 phased array TOFD flaw detector, new OmniScan MX3 fully focused phased array ultrasonic flaw detector); Ultrasonic thickness gauge: (27MG ultrasonic thickness gauge, 45MG ultrasonic thickness gauge, 38DL PLUS ultrasonic thickness gauge, DM5E ultrasonic thickness gauge, CL5 ultrasonic thickness gauge, MAGNA-MIKE 8600 Hall effect thickness gauge, ETG-100 electromagnetic high-temperature thickness gauge); Ultrasonic probe; Customized phased array probe; Eddy current flaw detector: (NORTEC 600 eddy current flaw detector); Hardness tester; DR flat panel detector: 1313 DX ,1515DXT-I ,2520DX ,2530HE,4343HE, Dexela 1207 ,Dexela 1313 ,Dexela 2121S ,Dexela CMOS Flat panel detector, XRD 0822 ,XRD 1611 ,XRD 1621 ,XRD 4343RF ,XRD 3025 ,XRpad 4336 ,XRpad 4343 F ,XRpad2 3025 ,XRpad2 4336。 Endoscopes: (IPLEX NX Olympus Endoscope, IPLEX GX/GT Olympus Endoscope, IPLEX G Lite Olympus Endoscope, IPLEX TX Olympus Endoscope, IPLEX YS Olympus Endoscope, XLGo+Industrial Video Endoscope GE, XL Detect+Industrial Video Endoscope GE New, UVin Professional UV Video Endoscope); Pulse generator: (DRP300 replaces Olympus' 5072PR, 5073PR); Alloy analyzer: (Vanta Olympus handheld alloy analyzer, DELTA Professional handheld alloy analyzer Olympus, DELTA Element handheld alloy analyzer Olympus) and other instruments and meters