Pneumatic twelve way switching valve

NegotiableUpdate on 01/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Pneumatic twelve way switching valve $r $n Operating pressure and temperature range: $r $n Operating pressure range of twelve way valve: 0-0.60MPa $r $n Operating temperature range of twelve way valve: 0-250 ℃ $r $n Operating pressure range of cylinder: 0.3-0.6MPa $r $n Operating temperature range of cylinder: 0-70 ℃ $r $n Switching times: Continuous operation at room temperature for more than 2 million times

Product Details


1. Purpose:
QH-QZ-12 typePneumatic twelve way switching valveUsed for sampling, quantifying, gas path switching, and other instruments and equipment with similar requirements for gas sample volume.


2. Main technical parameters
1) Use pressure and temperature range:

The operating pressure range of the twelve way valve is 0-0.60MPa
The operating temperature range of the twelve way valve is 0-250 ℃
The operating pressure range of the cylinder is 0.3 to 0.60MPa
The operating temperature range of the cylinder is 0-70 ℃

Switching times: Continuous operation at room temperature for more than 2 million times

2) Interface size:
Valve head interface: 1.6mm, 2mm, 3mm, 1/16 ', 1/8'
Cylinder interface: 1.6mm, 2mm, 3mm, 1/16 ', 1/8', tower type connector, quick twist connector, quick insert connector

3) Media used: gas, liquid

3. Outline and installation dimension diagram

Please refer to the six way valve

气动十二通切换阀

4. Working principle of switching valve

1. Working principle of cylinder

气动十二通切换阀

2. Switching principle of switching valve

气动十二通切换阀



5. Repeatability and cleanliness testing (see the diagram below)


Pneumatic twelve way switching valveThe cleanliness detection spectrum was obtained using the original Beijing Analytical Instrument Factory's sp-3420 gas chromatography, FID detector, range 12 (i.e. 10-12), 8M0.32 test column, column sampler temperature 200 ℃, column box temperature 200 ℃, detector temperature 250 ℃, as shown in Figure 2

The repeatability detection spectrum of the valve, column box at 100 ℃, injector at 150 ℃, detector at 150 ℃, with a range of 12 (i.e. 10-12), as shown in Figure 3

气动十二通切换阀

6. Usage and maintenance
a. Oil stains, dust, and all mechanical impurities should be prevented from entering the valve body
b. Oil stains, dust, and all mechanical impurities should be prevented from entering the cylinder
c. There should be no leakage at the connection between the inlet and outlet pipes and the valve body
d. There should be no looseness or sliding at the connection between the valve head and the cylinder to prevent improper switching

7. Common problems and solutions during the installation process of switching valves

气动十二通切换阀