Welcome Customer !

Membership

Help

Shenzhen Angwei Electronics Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shenzhen Angwei Electronics Co., Ltd

  • E-mail

  • Phone

  • Address

    6th Floor, Unit A, Building D2, TCL Science Park, 1001 Zhongshan Yuan Road, Nanshan District, Shenzhen

Contact Now

Plastic degradation rate tester (detection system)

NegotiableUpdate on 07/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The plastic degradation rate tester (detection system) creates the required environmental conditions and determines the final aerobic biodegradation ability of the material under controlled composting conditions by measuring the conversion rate of organic carbon to carbon dioxide during microbial degradation of the material.

Product Details

Product model: LZS-003
Product Name: Plastic Degradation Rate Tester
Product nickname: Plastic Degradation Detection System


System Overview:

Plastic degradation rate tester (detection system)Create the necessary environmental conditions and, under controlled composting conditions, determine the final aerobic biodegradation capacity of the material by microbial degradation of the material and measuring the conversion rate of organic carbon to carbon dioxide during the process.

塑料降解率测试仪(检测系统)

System principle:

Mix the experimental material with the inoculum and place it in a biodegradation system. The mixture undergoes aerobic biodegradation under set temperature conditions. The experimental materials are decomposed by microorganisms into carbon dioxide (CO2), water (H2O), mineralized inorganic salts containing these elements, and new biomass. Real time online detection of CO2 production through an infrared carbon dioxide analysis system, with software automatically recording and saving data. The ratio of actual CO2 production to theoretical CO2 production is the biodegradation rate of the sample. Simultaneously monitoring the production of O2 facilitates the evaluation and control of the entire degradation process. Meet the requirements of GB/T20197-2006- Definition, Classification, Identification and Degradation Performance Requirements for Degradable Plastics, as well as the referenced method standards for vermiculite method and composting method.

System features:

1. Intelligence

-Full color touch screen operation

-Real time human-machine linkage communication

-Dynamic setting of flow channel

2. Modularization

-Air path optimization design

-Flexible design of 12-72 channels

-Independent measurement unit

塑料降解率测试仪(检测系统)

3. High precision

-High precision temperature and flow control

-Temperature regulation accuracy ± 1 ℃

-Flow control accuracy ± 1.5% F.S

-Infrared carbon dioxide accuracy ± 1% F.S

4. Cloud services

-On site dynamic display

-Real time monitoring on mobile devices

-Cloud data sharing

-Real time recording on PC

塑料降解率测试仪(检测系统)

Plastic degradation standards:

1. GB/T 20197-2006- "Localization, Classification, Identification and Degradation Performance Requirements for Degradable Plastics"

2. GB/T 19277.1-2011- "Determination of final aerobic biodegradability of materials under controlled composting conditions - Method for determining released carbon dioxide - Part 1: General method"

3. GB/T 20197-2006- "Localization, Classification, Identification and Degradation Performance Requirements for Degradable Plastics" GB/T 19277.1-2011- "Determination of Final Aerobic Biodegradability of Materials under Controlled Composting Conditions - Method for Determining Carbon Dioxide Release - Part 1: General Method"

System composition:

Plastic degradation rate tester (detection system)It mainly includes the following units:

Gas supply system: optimized gas path design, quiet and low-noise;

● Biodegradation system: easy to operate, safe and energy-saving, real-time temperature control throughout the entire process;

● Degradation rate analysis system; Intelligent control, with an accuracy of 1% for all measurements

● Data processing software; Customized data collection and processing software, user-friendly design, * functionality, and easy operation. Full screen display of 36 set values, divided into homepage information summary, sampling point setting module, flow setting module, historical data module, alarm setting module, alarm information module, offline alarm module, historical curve module, and map display module;

● Exhaust gas treatment system: The exhaust gas is introduced into the absorption bottle for further experimental comparison.

塑料降解率测试仪(检测系统)

Plastic degradation rate tester (detection system)Technical parameters:

project

parameter

Degradation system

Rated exhaust pressure 0.7Mpa (adjustable), rated exhaust flow 2.16m3/h

Temperature range: RT=25-120 ℃ adjustable, temperature control accuracy: ± 1 ℃, temperature control method: PID+SSR

Degradable bottle: Customized glass bottle and corrosion-resistant seal, available in 3L (or other volume and material) from Sichuan cattle

air supply mode

Convective air circulation

number of channels

quantity12Position, 18 positions24Position36Position72Position selection

Carbon dioxide detection

Infrared measurement principle, multi range automatic switching measurement (optional 0-5000ppm, 0-20000ppm, 0-60000ppm),

Full range accuracy ≤± 1%

Oxygen detection

Electrochemical measurement principle, range: 0-21% vol, accuracy: ±2%F. S.

Gas flow control

Mass flow controller automatic control: 0~300mL/min, accuracy: ± 1.5% F.S

Gas flow monitoring

Mass flow meter: 0-200ml/min, accuracy: ± 1% F.S

Software and Systems

Customized software, PC control, online cloud platform

Automatic temperature control: automatic control of temperature, humidity, flow rate, etc., with manual intervention not exceeding once per month

Data management: Historical data can be queried, data statistics and analysis can be conducted, and test data can be exported

Software mobile end: can achieve real-time query on the mobile end, multiple people are online at the same time, and abnormal alarm reminders

communication interface

Standard USB communication interface and Ethernet cable interface, expandable network transmission interface

Alarm and power-off protection

Equipped with limit alarm function, power-off protection and data storage function, power-off connection function

Total machine power

Maximum 6.8KW

Power supply

220V AC,50HZ(380V AC,50HZ)

size

3082*1875*825MM(Wide)X height x depth) (varies in size according to different configurations)

Ambient temperature

5℃-40℃

protection

Leakage protection, overheating alarm, fault alarm