The OmniScan MX2 phased array flaw detector has one or two batteries (two hot swappable batteries can be accommodated in the battery compartment).
Product Details
Compatibility of OmniScan MX2 software

Technical specifications of phased array module

(Applicable to OMNI-M2 module)

module OmniScan airborne data acquisition OmniScan controlled by TomoView Equipped with analysis software General Specifications External dimensions (width x height x thickness) 226 mm x 183 mm x 40 mm
UT MXU 4.3R2 TomoView 2.10R19 with OSTV PA1 3.0R9 OmniPC 4.3R2 (8.9 in. x 7.2 in. x 1.6 in.)
TomoView 2.10R19 weight 1.6 kg(3.5 lb)
PA MXU 4.3R2 TomoView 2.10R19 with OSTV PA1 3.098 OmniPC 4.3R2 interface 1 phased array interface: Olympus PA interface
TomoView 2.10R19 2 UT interfaces: LEMO 00
UT2 MXU 4.3R2 TomoView 2.10R19 OmniPC 4.3R2 Number of focusing rules 256 pieces
TomoView 2.10R19 Probe recognition Automatic probe recognition
PA2 MXU 4.3R2 TomoView 2.10R19 with OSTV PA2 1.0R2 OmniPC 4.3R2 Pulse generator/receiver aperture 32 chips*
TomoView 2.10R19 Number of chips 128 chips*
pulse generator PA channel UT channel
OmniScan MX2Phased array flaw detectorTechnical specifications of the host voltage 40 V、80 V、115 V 95 V、175 V、340 V
General Specifications External dimensions (width x height x thickness) 325 mm x 235 mm x 130 mm pulse width Adjustable from 30 ns to 500 ns, with a resolution of 2.5 ns. Adjustable within the range of 30 ns to 1000 ns, with a resolution of 2.5 ns.
(12.8 in. x 9.3 in. x 5.1 in.) Pulse shape Negative square wave Negative square wave
weight 3.2 kilograms, without module, with one battery. output impedance < 25 Ω < 30 Ω
data storage storage device SDHC card, most standard USB storage devices, or Fast Ethernet* receiver PA channel UT channel
*In order to achieve excellenceAs a result, it is recommended to use Lexar ® Memory card. gain 0 dB~80 dB, The maximum input signal is 550 mVp-p (full screen height) 0 dB~120 dB, The maximum input signal is 34.5 Vp-p (full screen height)
Data file capacity 300 MB input impedance 65 Ω Pulse echo mode: 60 Ω
I/O port USB port 3 of them Pulse transmission and reception mode: 50 Ω
Audio alarm yes System bandwidth 0.6 MHz~18 MHz(–3 dB) 0.25 MHz~28 MHz(–3 dB)
video output Video Output (SVGA) Sound beam formation Scan type Fan shaped and linear
Ethernet 10/100 Mbps number of groups Up to 8
Input/output cable encoder Dual axis encoder line (orthogonal, upward, downward, or clock/direction) data collection Digital frequency 100 MHz
digital input 4 digital TTL inputs, 5V Maximum pulse rate Up to 10 kHz (C-scan)
digital output 4 digital TTL outputs, 5 V, 15 mA data processing PA channel UT channel
Collection opening/closing device Remote acquisition start TTL, 5V Number of data points Up to 8192
Power output line 5 V, 500 mA power output line (with short circuit protection) Real time average 2, 4, 8, 16 2, 4, 8, 16, 32, 64
call the police 3 TTL,5 V,15 mA detection RF, full wave, positive half wave, and negative half wave
analog output 2 analog outputs (12 bits), ± 5 V, 10 k Ω filtering 3 low-pass, 3 band-pass, and 5 high pass filters 3 low-pass filters, 6 band-pass filters, and 3 high pass filters (8 low-pass filters in TOFD configuration)
Step speed input 5 V TTL pace input Video filtering Smooth (adjusted according to the frequency range of the probe)
display display size 26.4 cm (10.4 inches) (diagonal) The data shows A-scan refresh rate Real time: 60 Hz
resolution 800 x 600 pixels data synchronization According to the internal clock 1 Hz~10 kHz
brightness 700 cd/m2 According to the encoder Dual axis: 1 step to 65536 steps
number of colors 16 million Programmable Time Correction Gain (TCG) points 32: Each focusing rule has a TCG curve.
type Thin film transistor liquid crystal display (TFT LCD) call the police alarm count 3 of them
power supply Battery Type Intelligent lithium-ion battery condition Any logical combination of gates
Number of batteries 1 or 2 batteries (two hot swappable batteries can be accommodated in the battery compartment) analog output 2
Battery power supply time Use two batteries for at least 7 hours
Environmental indicators Working temperature range -10 °C~45 °C
(14 ºF~113 ºF)
Storage temperature range -20 ° C to 60 ° C (-4 ° F to 140 ° F), with battery
-20 ° C to 70 ° C, without battery
relative humidity Under non condensing conditions at 45 ° C, the maximum relative humidity is 70%.
Intrusion protection rating Designed to meet IP66 rating
Anti collision rating Through the drop test of MIL-STD-810G 516.6
Compatibility of MX2 module MXU 4.1R8 and updated versions OMNI-M2-PA32128PR
MXU 4.0 and later versions OMNI-M2-PA1664
OMNI-M2-PA16128
OMNI-M2-PA32128
OMNI-M2-UT-2CH
MXU 3.1 and MXU 4.1R9 and updated versions OMNI-M-UT-8CH

Shanghai Jiuheng Instrument Co., Ltd. is a professional enterprise engaged in the research and development, production, sales, and service of instruments and meters. Ultrasonic flaw detectors: EPOCH 600 ultrasonic flaw detector, EPOCH 6LT ultrasonic flaw detector, EPOCH 650 ultrasonic flaw detector, EPOCH 1000 ultrasonic flaw detector, USM 36 ultrasonic flaw detector, USN 60 ultrasonic flaw detector, USM go+ultrasonic flaw detector Ominscan SXPhased array flaw detector、 OmniScan MX2 phased array TOFD flaw detector, new OmniScan MX3 fully focused phased array ultrasonic flaw detector); Ultrasonic thickness gauge: (27MG ultrasonic thickness gauge, 45MG ultrasonic thickness gauge, 38DL PLUS ultrasonic thickness gauge, DM5E ultrasonic thickness gauge, CL5 ultrasonic thickness gauge, MAGNA-MIKE 8600 Hall effect thickness gauge, ETG-100 electromagnetic high-temperature thickness gauge); Ultrasonic probe; Customized phased array probe; Eddy current flaw detector: (NORTEC 600 eddy current flaw detector); Hardness tester; DR flat panel detector: 1313 DX ,1515DXT-I ,2520DX ,2530HE,4343HE, Dexela 1207 ,Dexela 1313 ,Dexela 2121S ,Dexela CMOS Flat panel detector, XRD 0822 ,XRD 1611 ,XRD 1621 ,XRD 4343RF ,XRD 3025 ,XRpad 4336 ,XRpad 4343 F ,XRpad2 3025 ,XRpad2 4336。 Endoscopes: (IPLEX NX Olympus Endoscope, IPLEX GX/GT Olympus Endoscope, IPLEX G Lite Olympus Endoscope, IPLEX TX Olympus Endoscope, IPLEX YS Olympus Endoscope, XLGo+Industrial Video Endoscope GE, XL Detect+Industrial Video Endoscope GE New, UVin Professional UV Video Endoscope); Pulse generator: (DRP300 replaces Olympus' 5072PR, 5073PR); Alloy analyzer: (Vanta Olympus handheld alloy analyzer, DELTA Professional handheld alloy analyzer Olympus, DELTA Element handheld alloy analyzer Olympus) and other instruments and meters