- Phone
-
Address
Building B4, Phase III, Science and Technology Innovation Center, No. 3 Gutan Avenue, Gaochun Economic Development Zone, Nanjing City, Jiangsu Province
Nanjing Nuojin Expressway Analytical Instrument Factory
Building B4, Phase III, Science and Technology Innovation Center, No. 3 Gutan Avenue, Gaochun Economic Development Zone, Nanjing City, Jiangsu Province
NJ-SCBS-200Petroleum fully automatic closed flash point testerUnder specified conditions, when the oil is heated to a certain temperature, the mixture of oil vapor and surrounding air will ignite upon contact with the flame. The low flash temperature is called the flash point value of the oil. Fully automatic closed flash point tester according to national standardsGB/T261-2008Determination of Flash Point by Binsky-Martin's Closed Cup Method "andASTMD93The regulations require manufacturing and application in departments such as petroleum, chemical, power, environmental protection, railway, and scientific research, making it an ideal instrument for conducting closed flash point testing.
NJ-SCBS-200Petroleum fully automatic closed flash point testertechnical parameters
display mode |
5inch65K(Resolution)800*600)Chinese touch screen display |
Measurement method: |
Thermocouple differential detection formula |
Measuring range: |
room temperature-350℃ resolution0.1℃ |
Ignition method: |
No gas source electronic ignition |
Repeatability: |
National standard: flash point value<104Allowable deviation at ℃ ±1℃, flash point value ≥104Allowable deviation at ℃ ±2℃ |
printer: |
Low energy high-speed thermal printer,56Millimeter paper width |
Temperature detection |
Imported platinum resistor(Pt100Ω) |
Cooling method: |
forced air cooling |
Self checking function: |
Automatic diagnosis of instrument faults |
Dimensions and weight: |
450X280X290 mm、5kilogram |
NJ-SCBS-200 Fully Automatic Closed Flash Point TesterFunctional Features
1. Adopting a new high-speed signal processor control, adaptivePIDControl algorithm, automatically adjust the heating curve according to standard requirements
2. Built in atmospheric pressure automatic detection chip, automatic measurement, calibration and correction of atmospheric pressure, and automatic correction of flash point value.
3. Automatic measurement completion of lifting, mixing, ignition, detection, alarm, cooling, and printing instruments
4. Safe without gas source, platinum alloy electric heating wire ignition method, safe, stable, reliable, high testing accuracy
5. Differential detection, automatic correction of system deviation, automatic stop detection and alarm for temperature *
【execution standard】
GB/T261-2008 "Determination of flash point Binsky
-Martin's Closed Cup Method ASTMD93
【Standard Configuration】
Fully automatic closed flash point tester host, oil cup, printing paper, power cord, etc
Optional accessories: printing paper, ignition wire, oil cup, etc