Welcome Customer !

Membership

Help

Nanjing Nuojin Expressway Analytical Instrument Factory
Custom manufacturer

Main Products:

instrumentb2b>Products

Nanjing Nuojin Expressway Analytical Instrument Factory

  • E-mail

  • Phone

  • Address

    Building B4, Phase III, Science and Technology Innovation Center, No. 3 Gutan Avenue, Gaochun Economic Development Zone, Nanjing City, Jiangsu Province

Contact Now

Petroleum fully automatic closed flash point tester

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The NJ-SCBS-200 petroleum fully automatic closed flash point tester adopts a new high-speed signal processor control, adaptive PID control algorithm, and automatically adjusts the heating curve according to standard requirements. It is equipped with an automatic atmospheric pressure detection chip, which automatically measures, corrects and corrects the flash point value of atmospheric pressure. Applied in departments such as petroleum, chemical, power, environmental protection, railway, and scientific research, it is an ideal instrument for conducting closed flash point testing.

Product Details

NJ-SCBS-200Petroleum fully automatic closed flash point testerUnder specified conditions, when the oil is heated to a certain temperature, the mixture of oil vapor and surrounding air will ignite upon contact with the flame. The low flash temperature is called the flash point value of the oil. Fully automatic closed flash point tester according to national standardsGB/T261-2008Determination of Flash Point by Binsky-Martin's Closed Cup Method "andASTMD93The regulations require manufacturing and application in departments such as petroleum, chemical, power, environmental protection, railway, and scientific research, making it an ideal instrument for conducting closed flash point testing.

NJ-SCBS-200Petroleum fully automatic closed flash point testertechnical parameters

display mode

5inch65K(Resolution)800*600)Chinese touch screen display

Measurement method:

Thermocouple differential detection formula

Measuring range:

room temperature-350 resolution0.1

Ignition method:

No gas source electronic ignition

Repeatability:

National standard: flash point value<104Allowable deviation at ℃ ±1℃, flash point value ≥104Allowable deviation at ℃ ±2
International standard: Flash point value ≤110Allowable deviation at ℃ ±1℃, flash point value>110Allowable deviation at ℃ ±2

printer:

Low energy high-speed thermal printer,56Millimeter paper width

Temperature detection

Imported platinum resistor(Pt100Ω)

Cooling method:

forced air cooling

Self checking function:

Automatic diagnosis of instrument faults

Dimensions and weight:

450X280X290 mm5kilogram

NJ-SCBS-200 Fully Automatic Closed Flash Point TesterFunctional Features

1. Adopting a new high-speed signal processor control, adaptivePIDControl algorithm, automatically adjust the heating curve according to standard requirements

2. Built in atmospheric pressure automatic detection chip, automatic measurement, calibration and correction of atmospheric pressure, and automatic correction of flash point value.

3. Automatic measurement completion of lifting, mixing, ignition, detection, alarm, cooling, and printing instruments

4. Safe without gas source, platinum alloy electric heating wire ignition method, safe, stable, reliable, high testing accuracy

5. Differential detection, automatic correction of system deviation, automatic stop detection and alarm for temperature *

execution standard

GB/T261-2008 "Determination of flash point Binsky

-Martin's Closed Cup Method ASTMD93
Standard Configuration

Fully automatic closed flash point tester host, oil cup, printing paper, power cord, etc

Optional accessories: printing paper, ignition wire, oil cup, etc