1. The application major is designed for the petrochemical sector and can directly measure the temperature of liquid, steam, gas media, and solid surfaces within the range of -200 ℃ to 1600 ℃. 2. The working principle of a thermocouple is that its electrodes are composed of two different conductor materials. When the measuring end is in contact with the reference .....

Product Details

1. Application

Specially designed for the petrochemical sector, it can directly measure temperature of liquid, vapor, gas media, and solid surfaces within the range of -200 ℃ to 1600 ℃.

2. Working principle

The electrodes of a thermocouple are composed of two different conductor materials. When there is a temperature difference between the measuring end and the reference end, a thermoelectric potential is generated, and the working instrument displays the temperature value corresponding to the thermoelectric potential.
Thermistor is based on the principle that resistance is a function of temperature. When there is a temperature change in the measured medium, its resistance value also changes accordingly, and the working instrument displays the temperature value corresponding to the resistance value.

3. Main technical parameters

Product execution standards:
IEC1515
IEC584
IEC751
JB/T5518-91
JB/T5582-91

4. Nominal pressure

Generally refers to the static external pressure that the protective tube can withstand at room temperature without breaking. The allowable working pressure is not only related to the material, diameter, and wall thickness of the protective tube, but also to its structural form, installation method, and the flow rate and type of the measured medium.

5. Temperature range and allowable deviation

thermocouple

model graduation mark Tolerance level
Allowable deviation Temperature measurement range ℃ Allowable deviation Temperature measurement range ℃
WRN K ±1.5 ℃ -40-+375 ±2.5 ℃ -40-+333
±0.004 ltl 375-1000 ±0.0075 ltl 333-1200
WRE E ±1.5 ℃ -40-+375 ±2.5 ℃ -40-+333
±0.004 ltl 375-800 ±0.0075 ltl 333-900
WRP S ±1℃ 0-1100 ±2.5 ℃ 0-600
± 1+0.003 (t-1100) 1100-1600 ±0.0025 ltl 600-1600
WRQ R ± 1 ℃ 0-1100 ±2.5 ℃ 0-1100
± "1+0.003 (t-1100)" 1100-1600 ±0.0025ltl 1100-1600
WRR B
±0.0025ltl 600-1700
thermal resistor
model graduation mark Temperature measurement range ℃ accuracy class allowable deviation
WZP Pt100 -200-+500 A ±(0.15+0.002)ltl
B ±(0.30+0.005)ltl
WZC Cu50 Cu100 -50-+100 ---- ±(0.30+0.005)ltl