1. Product principle
The sulfides in the water sample are acidified, and the generated hydrogen sulfide enters the absorption bottle/absorption color tube with the carrier gas (nitrogen) and is absorbed by the absorption solution (zinc acetate sodium acetate solution or 2% sodium hydroxide solution). The corresponding analysis method is selected to analyze and determine the sulfur ions absorbed in the absorption bottle/absorption color tube.
2. Product execution standards
GB/T16489-1996 "Determination of Sulfides in Water Quality - Methylene Blue spectrophotometric method"
HJ/T600-2000 "Determination of Sulfides in Water Quality - Iodometric Method"
Water quality sulfide acidification blowing instrumentMain features:
1. Using a constant temperature water bath heating method, the heating is uniform
2. Electric control of sample rack and valve system lifting (optional for 4S)
3. Rotating sample holder, front mounted sample, easy to operate
4. The nitrogen flow rate of each sample is independently controlled and adjusted or turned off
5. Needle valve gas flowmeter accurately controls and displays the total gas consumption
6. Adopting stainless steel material or PTFE coating, it has the characteristics of acid and alkali resistance, corrosion resistance, and high temperature resistance

Product Model |
JT-DCY-4S |
JT-DCY-4SL |
Number of processed samples |
4 of them |
4 of them |
gas flow meter |
0-3L/min |
0-3L/min |
Heating method |
Automatic temperature control and constant temperature water bath |
Automatic temperature control and constant temperature water bath |
heating power |
1000W |
1000W |
temperature range |
Room temperature -99.9 ℃ |
Room temperature -99.9 ℃ |
display mode |
digital display |
digital display |
temperature control accuracy |
±1℃ |
±1℃ |
power supply voltage |
220V 50HZ |
220V 50HZ |
lifting method |
manual lifting |
Electric lifting |
Overall dimensions |
530×390×620mm |
530×390×620mm |
Parameters of Sulfide Blowoff Device for Hangzhou Water Quality
Operation method:
1. Turn on the power (make sure distilled water has been poured into the water bath) and the cooling fan is running
2. Set the temperature of the constant temperature water area according to the national standard method (temperature controller)
3. Raise the sample holder to the appropriate height (lift switch)
4. Load the reaction bottle and absorption tube containing the water sample to be tested into the sample rack
5. Connect all nitrogen blow pipes and check the airtightness of the device.
6. Pass nitrogen gas and adjust the rotor flowmeter to the appropriate flow rate according to the national standard requirements. Control the total nitrogen consumption of the sample.
7. Adjust the nitrogen flow rate of each sample to be the same based on the speed and quantity of bubbles rising in the absorption tube.
8. Lower the sample holder to an appropriate depth in a constant temperature water bath.
9. Preprocess according to the operating steps of the national standard method.
10. During the preprocessing process, observe and adjust the total nitrogen flow rate and the nitrogen flow rate of the absorption color tube at any time.
11. Set the temperature of the thermostat to below room temperature after use, and turn off the power after the water bath temperature drops.