Welcome Customer !

Membership

Help

Beijing Guancheng Measurement Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

PMP131 pressure transmitter

NegotiableUpdate on 05/16
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

PMP131 pressure transmitter

Product Details

Product Features

Adopting technology leading American origin silicon piezoresistive sensors, high-performance digital linear and temperature compensation, all stainless steel small size

Chemical structure, wide pressure measurement range (0-2KPa, 0-60MPa), good long-term stability, extremely strong applicability,

It has explosion-proof, sanitary, submersible, and high-temperature types. PMP131 and PMP131C are standard types; PMP131A is tightening

Type; PMP131B Pyongyang membrane type.

working principle

The pressure sensor based on the principle of silicon piezoresistive is a precision silicon electric sensor made by vacuum diffusing semiconductors on a silicon substrate

Resistance strain bridge. It is separated from the measured medium by a layer of stainless steel corrugated sheet, and the strain bridge is connected to the stainless steel corrugated sheet

There is an intermediate fluid filled between them - silicone oil. When pressure P acts on the corrugated sheet and is transmitted to the strain bridge through the intermediate fluid, the bridge

The change in resistance causes the bridge to lose balance and output a series of voltage signals proportional to the pressure P. Through signal amplification, the circuit

Convert to standard electronic signal output.



Technical Specifications

·Relative pressure:

MP131 type: minimum measurement range (0-2) kPa; Maximum measurement range (0-4) MPa

PMP131A type: minimum measurement range (0-10) kPa; Maximum measurement range (0-4) MPa

PMP131B type: minimum measurement range (0-10) kPa; Maximum measurement range (0-4) MPa

PMP131C type: minimum measurement range (0-4) MPa; Maximum measurement range (0-60) MPa

·Negative relative pressure:

PMP131 type: minimum measurement range (-2~2) kPa; Maximum measurement range (-0.1~4) MPa

PMP131A type: minimum measurement range (-10~10) kPa; Maximum measurement range (-0.1~4) MPa

PMP131B type: minimum measurement range (-10~10) kPa; Maximum measurement range (-0.1~4) MPa

PMP131C type: minimum measurement range (-0.1~4) MPa; Maximum measurement range (-0.1~60) MPa

·Absolute pressure:

PMP131 type: minimum measurement range (0-15) kPa; Maximum measurement range (0-4) MPa

PMP131A type: minimum measurement range (0-15) kPa; Maximum measurement range (0-4) MPa

PMP131B type: minimum measurement range (0-15) kPa; Maximum measurement range (0-4) MPa

·Measurement accuracy:

0.2% FS, 0.5% FS (including linearity, hysteresis, and repeatability). )

·Long term stability:

Annual ≤ ± 0.1% FS

·Allowable ambient temperature:

Standard type -20 ℃~+70 ℃; Explosion proof type -20 ℃~+60 ℃;

·Allowable medium temperature:

Standard type -30 ℃~+120 ℃; High temperature type 0 ℃~+160 ℃;

Sanitary clamp type -30 ℃~+140 ℃;

·Allowable storage temperature:

-40℃~+120℃;

·Temperature impact:

0.5% FS: Temperature compensation range -20℃~+80℃; The impact of the entire temperature range is ≤± 1%

0.2% FS: Temperature compensation range -20℃~+80℃; The impact of the entire temperature range is ≤± 1%

Or special requirements agreed upon

·Contact with medium

Partial materials:

Sensor corrugated isolation diaphragm made of stainless steel 316L

Process connectors made of stainless steel 304 or specified special requirements

·Shell material:

Stainless Steel 304

·Protection level:

Right angle elbow IP65; Overall cable IP65; Aviation plug IP65;

Delphi connector IP65; Integrated air conducting cable+external thread M20X1.5IP67;

Integrated air conducting cable IP68 (produced according to customer requirements for water depth);

Or special requirements agreed upon

·Working power supply:

(4-20) mA output type (12-30) VDC; (0.5-4.5) VDC output type 5VDC;

(1-5) VDC output type (12-30) VDC; (0-10) VDC output type (15-30) VDC

Or special agreement requirements

·Signal output:

4-20mA analog type (two-wire system); 0.5-4.5VDC (three wire system);

(1-5) VDC (three wire system); (0-10) VDC (three wire system);

Or special requirements agreed upon

·Electromagnetic compatibility

Anti interference capability:

Interference radiation complies with EN50081-1; Anti interference complies with EN50082-2

Field strength of 10V/m complies with NAMUR industrial standards

·Process connection:

PMP131 type, PMP131C type:

External thread M20 × 1.5; External thread G1/2; External thread R1/2; External thread NPT1/2; External thread G1/4;

PMP131B type:

External thread M20 × 1.5, G1/2 flat inlaid membrane type; Three clip ISO2852 maximum outer diameter 50.5;

Three clip ISO2852 maximum outer diameter 64;

Sanitary Pyongyang membrane type (external thread G1/2, front end with O-ring seal);

G1 type external thread front end surface sealing type; G1 external thread conical inclined metal seal type;

Or special requirements agreed upon

PMP131A type:

External thread G1/4; External thread G1/8; External thread NPT1/4; External thread NPT1/8;

Internal thread with top pin 7/16-20UNF (for central air conditioning); External thread M16X1.5 flat inlaid diaphragm type

·Electrical connection:

PMP131、PMP131B、PMP131C 型:

Right angled elbow socket type (Hosman plug PG 9, cable outer diameter 4 mm~6mm);

Overall cable type; Integrated air conducting cable type (suitable for IP68);

Aviation plug elbow type (with 1m cable); Aviation plug-in type;

Or special requirements agreed upon

PMP131A type:

Right angled elbow socket type (Hosman plug PG 7) integral cable type; Parker connector type;

Aviation plug elbow type (with 1m cable); Aviation plug-in type; Or special requirements agreed upon

·Allowable overload pressure:

PMP131, PMP131A, PMP131B types: rated pressure value of 3 times

PMP131C type:

When the rated pressure value is less than 35MPa, it is twice the rated pressure value

When the rated pressure value is ≥ 35MPa, it is 1.5 times the rated pressure value



Exterior Structure (PMP131/PMP131C)

When installing instruments, it is forbidden to rotate right angle elbows or aviation plugs by hand or with tools

a: Right angled elbow type; b: Overall cable standard type; c: Integrated cable explosion-proof type; d: Aviation plug elbow type; e: Aviation plug-in type

f: Built in external thread; g: Flat inlaid external thread; h: Sanitary flat inlaid external thread; I: Three clip head type;
z: Front end surface sealing type; q: Cone shaped inclined metal sealing type; r: Three clip head type;
s: External thread M16X1.5; t: External thread G1/4 A; u: Internal thread G1/4; v: External thread 1/4NPT;

Exterior Structure (PMP131A)
electrical connection
In environments with strong interference, in order to ensure the normal operation of instruments, they should be reliably grounded according to relevant instrument grounding technical specifications!

Order Selection Table