Technical Specifications
|
·Measurement range
|
Relative pressure: PMC131 minimum measurement range: 0-0.5kPa maximum measurement range: 0-2MPa
|
|
|
|
The minimum measurement range of PMC131A is 0-2kPa; Maximum measurement range 0-4MPa
|
|
|
|
The minimum measurement range of PMC131B is 0-4MPa; Maximum measurement range 0-60MPa
|
|
|
|
Negative relative pressure: PMC131 minimum measurement range -0.5~0kPa; Maximum measurement range -0.1~2MPa
|
|
|
|
The minimum measurement range of PMC131A is -2~2kPa; Maximum measurement range -0.1~4MPa
|
|
|
|
The minimum measurement range of PMC131B is -0.1 to 4MPa; Maximum measurement range -0.1~0MPa
|
|
|
|
Absolute pressure: PMC131 has a minimum measurement range of 0-2kPa; Maximum measurement range 0-2MPa
|
|
|
|
The minimum measurement range of PMC131A is 0-15kPa; Maximum measurement range 0-4MPa
|
|
|
·Measurement accuracy
|
0.5% FS, 0.2% FS (including linearity, hysteresis, and repeatability). )
|
|
|
|
The measurement accuracy is limited to 0.5% FS when the range is below 2kPa
|
|
|
·Long term stability
|
Annual ≤ ± 0.1% FS
|
|
|
·Allowable working temperature
|
Allowable ambient temperature: -40 ℃ to+85 ℃; Allowable medium temperature: -40 ℃ to+120 ℃;
|
|
|
|
Allowable storage temperature: -40 ℃ to+80 ℃
|
|
|
·Temperature influence
|
0.2% - Compensation temperature -20 ℃~+80 ℃ full temperature range impact ≤± 1%
|
|
|
|
0.5% - precision compensation temperature -20 ℃ to+80 ℃, with a total temperature range impact of ≤± 1%;
|
|
|
|
Special requirements agreed upon
|
|
|
·Sensor type
|
PMC131- Ceramic Sensor; PMC136A - Low voltage type of silicon piezoresistive sensor;
|
|
|
|
PMC131B - High voltage type of silicon piezoresistive sensor;
|
|
|
·Signal output
|
(4-20) mA analog type (two-wire system); Or special requirements agreed upon
|
|
|
|
(4-20) mA intelligent type with HART communication protocol (two-wire system);
|
|
|
·Electromagnetic compatibility resistance
|
Interference radiation complies with EN50081-1; Anti interference complies with EN50082-2;
|
|
|
·Interference
|
Field strength of 10V/m complies with NAMUR industrial standards
|
|
|
·Working power supply
|
(4-20) mA output type (12-30) V DC
|
|
|
·Process Connection
|
PMC131: External thread M20 × 1.5, G1/2, 1/2NPT, G1 1/2 or special requirements agreed upon
|
|
|
|
PMC1131: External thread M20 × 1.5 G1/2、1/2NPT、 Or special requirements agreed upon
|
|
|
·Electrical connection
|
Right angled elbow socket type (Hosman plug PG 9, cable outer diameter 6mm~8mm);
|
|
|
|
Overall cable type; Integrated air conducting cable type (suitable for IP68); Or special requirements agreed upon
|
|
|
·Working voltage
|
18-35VDC analog output
|
|
|
·Load resistance
|
Current output RLMAX [Ω] ≤ (US-12V/0.02A) (LMAX [Ω] ≤ 600 Ω at 24V,
|
|
|
|
RLMAX [Ω] ≤ 900 Ω at 30V) voltage output RLmin [Ω] ≥ 5 k Ω
|
|
|
·Contact with medium
|
PMC131 sensor material: 96% or 99% alumina ceramic;
|
|
|
Partial materials
|
Process connectors: Stainless steel 304 or special requirements as agreed upon
|
|
|
|
PMC131A sensor corrugated isolation film”Stainless steel 316L sheet
|
|
|
|
Process connectors: Stainless steel 304 or special requirements as agreed upon
|
|
|
|
PMC131B sensor corrugated isolation diaphragm: stainless steel 316L
|
|
|
|
Process connectors: Stainless steel 304 or special requirements as agreed upon
|
|
|
·Sealing ring material
|
PMC131: Fluororubber or specific requirements; PMC1131: Welding structure without sealing ring;
|
|
|
|
PMC135B: Nitrile rubber or specific requirements
|
|
|
·Shell material
|
Stainless Steel 304
|
|
|
·Protection level
|
Right angle elbow IP65; Overall cable IP65; Integrated air conducting cable IP68 (according to
|
|
|
|
The customer requires deep water production; Or special requirements agreed upon
|
|
|
·Allow environmental humidity
|
98%RH
|