Technical Specifications
|
·Measurement range
|
Minimum measurement range (0-150) Pa; Maximum measurement range (0-2) MPa
|
|
|
·Measurement accuracy
|
The comprehensive error (including linearity, repeatability, and hysteresis) is better than 0.1%
|
|
|
|
1: 1~5:1 range ratio: 0.1% set range,
|
|
|
|
5: 1~10:1 range ratio: (0.05%+0.01% × TD)% set range
|
|
|
·Long term stability
|
Exceeding 0.15% F.s annually
|
|
|
·Allowable medium temperature
|
(-40~110)℃
|
|
|
·Allow ambient temperature
|
(-40~85)℃
|
|
|
·Allow storage temperature
|
(-40~85)℃
|
|
|
·Temperature influence
|
Relative to the standard range of 25 ℃≤± 0.4%
|
|
|
·Sensors allow
Working static pressure
|
Unidirectional and bidirectional maximum allowable static pressure PN13MPa
|
|
|
·Temperature influence
|
Under 100% condition, the impact is ≤ 0.25%
|
|
|
·Damping
|
0~40S continuously adjustable
|
|
|
·Anti vibration
|
2g 1000HZ ±0.05%g
|
|
|
·Impact resistance
|
50g 11mesc
|
|
|
·Electromagnetic compatibility characteristics
|
Compliant with IEC801 standard
|
|
|
·Load characteristics
|
Corresponding to power supply voltage impedance of 50 Ω~1000 Ω
|
|
|
·Sensors allow for overvoltage
|
3 times the standard range pressure
|
|
|
·Sensor range ratio
|
10: 1. Continuously adjustable zero point with 100% reverse migration capability
|
|
|
·Signal output
|
4-20mA linear output two-wire system with HART communication protocol
|
|
|
|
4-20mA square root output two-wire system with HART communication protocol
|
|
|
·Start time
|
3S without preheating required
|
|
|
·Power supply
|
12V~45VDC
|
|
|
·Power supply impact
|
≤ 0.005% V of output range
|
|
|
·Electrical connection
|
M4 screw grounding terminal suitable for 0.5~1.5mm ² with cable sealing shell suitable for outer diameter 6~8mm
|
|
|
·Process Connection
|
1/4NPT internal thread pressure pipe connection, M10 internal hole thread installation bracket connection
|
|
|
·Contact with medium
|
Sensor Ripple Diaphragm: Stainless Steel 316, Hastelloy C
|
|
|
Partial materials
|
Sensor sealing ring: Fluororubber EPDMPTFE, Kalrez
|
|
|
|
Elliptical flange: stainless steel 316; Hastelloy C
|
|
|
·Non contact with the medium
|
Shell: Die cast aluminum strip with epoxy resin coating
|
|
|
Partial materials
|
Nameplate: Stainless steel 304; Intermediate liquid silicone oil or anaerobic oil in sensors
|
|
|
|
Fastener: Stainless steel
|
|
|
·On site display
|
LCD 3 1/2 digital display
|
|
|
·Protection level
|
IP66
|
|
|
·Weight
|
About 1kg
|
|
|
·Explosion proof grade
|
Explosion proof Ex d Ⅱ C T5; Intrinsically safe Ex ia Ⅱ C T5
|
|
|
·Allow environmental humidity
|
100%RH
|