Technical Specifications
|
·Measurement range
|
The minimum measurement range of relative pressure is (0-400) Pa; Maximum measurement range (0-35) MPa
|
|
|
|
Minimum measurement range of absolute pressure (0-1.75) KPa; Maximum measurement range (0-35) MPa
|
|
|
|
Minimum measurement range of negative relative pressure (-500~500) Pa; Maximum measurement range (-0.1~3.5) MPa
|
|
|
·Measurement accuracy
|
The comprehensive error (including linearity, repeatability, and hysteresis) is better than 0.1%, and can be set at 0.075 for special requirements
|
|
|
|
1: 1~10:1 range ratio of 0.1% set range,
|
|
|
|
10: 1~20:1 Range ratio: (0.05%+0.01% × TD)% Set range
|
|
|
·Long term stability
|
Exceeding 0.15% F.S annually; Better than 0.2% F.S in five years
|
|
|
·Allowable medium temperature
|
(-40~120)℃
|
|
|
·Allow ambient temperature
|
(-40~85)℃
|
|
|
·Allow storage temperature
|
(-40~85)℃
|
|
|
·Temperature influence
|
Relative to the standard range of 25 ℃≤± 0.4%
|
|
|
·Damping
|
0~40S continuously adjustable
|
|
|
·Anti vibration
|
2g 1000HZ ±0.05%g
|
|
|
·Impact resistance
|
50g 11mesc
|
|
|
·Electromagnetic compatibility characteristics
|
Compliant with IEC801 standard
|
|
|
·Sensors allow for overvoltage
|
3 times the standard range pressure
|
|
|
·Signal output
|
4-20mA linear output two-wire system with HART communication protocol
|
|
|
|
Zero point minimum alarm current range: 3.8mA
|
|
|
|
Maximum alarm current range at full capacity: 21mA
|
|
|
·Start time
|
3S without preheating required
|
|
|
·Contact with medium
|
Process connectors: Stainless steel 316, Hastelloy C
|
|
|
Partial materials
|
Sensor diaphragm: stainless steel 316, Hastelloy C
|
|
|
·Non contact with the medium
|
Shell: Die cast aluminum strip with epoxy resin coating
|
|
|
Partial materials
|
Sensor filling liquid silicone oil anaerobic oil
|
|
|
·On site display
|
LCD 3 1/2 precision digital display LCD analog strip display
|
|
|
·Protection level
|
IP66
|
|
|
·Weight
|
About 1kg
|
|
|
·Explosion proof grade
|
Explosion proof Ex d Ⅱ C T5, intrinsically safe Ex ia Ⅱ C T5
|
|
|
·Allow environmental humidity
|
100%RH
|