PMC47 pressure transmitter

Product Details


Product Features

Adopting ceramic capacitive sensors or metal diffusion silicon sensors, it has wide applicability and is suitable for micro pressure measurement and vacuum measurement,

High voltage measurement, high and low temperatureCorrosion resistance pressure measurement and high cleanliness condition measurementFeaturing both analog and intelligent capabilities, with a high precision of 0.1%,

10: 1 wide range ratio, digital linear temperature compensation, with HART communication protocol, inherently safe, stainless steel casing

More suitable for clean environments.


working principle

·Ceramic capacitive dry sensor

A flat capacitor structure is composed of 96% or 99% alumina ceramic film. The medium pressure of the sensor directly acts on the ceramic transmission

Sensor membrane causes displacement of the measuring membrane. Normal pressure causes a displacement of 0.025mm in the measuring diaphragm. Overpressure only causes

Measure the displacement of the diaphragm by 0.1mm. At this point, the capacitance generated by the displacement of the diaphragm is detected by an electronic component directly connected to it,

Amplify and convert to standard signal output.

·Metal diffusion silicon piezoresistive sensor

A pressure sensor is a standard silicon resistance strain bridge made by vacuum diffusing semiconductors on a silicon substrate. It is directly connected to the tested medium

There is a layer of stainless steel corrugated sheet at the junction, and an intermediate fluid - silicone oil - is filled between the strain bridge and the stainless steel corrugated sheet. When the pressure P

Acting on the corrugated sheet and transmitted to the strain bridge through the intermediate fluid, the change in bridge resistance causes the bridge to lose balance and output a series of outputs that are proportional to the pressure

A proportional voltage signal. By amplifying the signal, the circuit is converted into a 4-20mA output.



Technical Specifications

·Measurement range

Relative pressure: maximum measurement range (0-4) MPa; Minimum measurement range (0-800) Pa

Ceramic capacitive sensor

Negative relative pressure: maximum measurement range (-0.1 to+2) MPa; Minimum measurement range (-500 to+500) Pa

Absolute pressure: maximum measurement range (0~4) MPa; Minimum measurement range (0~1) KPa

Diffuse silicon piezoresistive sensor

Relative pressure: maximum measurement range (0-35) MPa; Minimum measurement range (0-1) KPa

Absolute pressure: maximum measurement range 0~35MPa; Minimum measurement range 0~3.5KPa

·Measurement accuracy

Comprehensive error (including linearity, hysteresis, and repeatability)

Intelligent type: 0.1% standard range; Analog type: 0.2% standard range

·Long term stability

Annually ≤ ± 0.1%; Every three years ≤ ± 0.25%

·Allowable medium temperature

PMC43 type: -40 ℃ to+110 ℃; PMC47 type: -40 ℃~+135 ℃, can last for one hour at 150 ℃

·Allow ambient temperature

-40℃~+85℃

·Allow storage temperature

-40℃~+85℃

·Temperature influence

PMC47 analog type

Within the range of medium temperature+85 ℃~135 ℃, every 10K ± 0.25%

PMC47 Intelligent Type

Within the range of medium temperature+85 ℃~135 ℃, every 10K ± 0.2%

·Signal output

Analog type: 4-20mA two-wire system; On site DIP switch adjustment 0S or 2S

Intelligent type: 4-20mA two-wire system with HART communication protocol

Alarm signal: Zero point 3.6mA, full range 22mA

·Damping time

On site DIP switch adjustment 0S or 2S, adjust 0-40S using a HART communication controller or microcomputer

·Resolution

1μA

·Electromagnetic compatibility resistance

Radio frequency electromagnetic field radiation immunity

The radiation immunity induced by radio frequency field complies with GB/T17626.3-1998.10V/m and meets Class A.

Conducted immunity induced by radio frequency field

The conducted immunity of RF field induction complies with GB/T17626.6-1998. U=10V and meets Class A.

·Working power supply

Analog type: 11.5~45VDC; Intelligent type: 12~36V DC

·Contact with medium

Ceramic sensor: 96% or 99% alumina

Partial materials

Ceramic sensor sealing materials: Fluororubber, FKMViton, EPDM rubber, Perfluororubber Kalrez

Metal diffusion silicon piezoresistive sensor: stainless steel 316L

Metal diffusion silicon piezoresistive sensor sealing material: stainless steel welding

·Process connection materials

Stainless steel 304, 316L, Hastelloy C276 or other agreed upon materials

·Non contact with the medium

Partial materials

Shell made of stainless steel 304

·Vibration impact

No effect under the conditions of 2g 15HZ-150HZ and 1g 150HZ-2000HZ

·Preheating time

Simulated 200ms; Intelligent 2s

·Response time

Analog 60ms; Intelligent 230ms

·Set time

Analog 180ms; Intelligent 650ms

·Protection level

Standard IP66; Optional IP68 rating

·Allow environmental humidity

100%RH



Exterior structure

Size unit: mm, shell made of stainless steel ASI316L max.1.4Kg;
The values in parentheses for instruments with visual covers or blind covers are optional.

Electrical connection(Analog and intelligent electronic module wiring

Two core cable directly connected to the wiring terminal of the electronic module
·Power supply: Analog type: 11.5~45 VDC; Intelligent type: 12~36V DC
·Cable: Analog type: Two core instrument cable Intelligent type: Shielded twisted pair cable
Wiring terminal: 0.14~2.5mm ² (AWG25~14)
·Contains polarity reversal protection circuit, resistant to high frequency and overvoltage impact
·Signal testing: The current output value can be measured using the plug on the electronic module without affecting the process measurement
·Connect the shielding layer or grounding terminal (if present) to the internal grounding terminal, do not connect to terminal 3

load characteristic


Instrument installation(Installation Guide)

PMC43 and PMC47 adopt the same connection method as ordinary pressure gauges, and the specific installation position depends on the requirements of the working conditions
·Gas: higher than the pressure inlet
·Liquid: below or level with the pressure inlet
·Steam/water vapor: below the pressure inlet
(It is recommended to use a circular device)
Cleaning uses diffused silicon metal film sheets
Metal film cannot be squeezed or cleaned by hard objects
Wall mounted and pipe mounted installation
PMC43 adopts wall mounted or pipe mounted (vertical and horizontal) installation, and installation accessories need to be selected
Unit size: mm

Order Selection Table