Welcome Customer !

Membership

Help

Shanghai Suhuo Electric Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Overvoltage protector tester successfully detects 1mA DC voltage

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The overvoltage protector tester is capable of detecting 1mA DC voltage using waveform detection and Fourier transform to constantly monitor the discharge current. When the discharge current is detected, the high voltage is immediately recorded and the high voltage power supply is cut off within 0.2 seconds. The test results have high accuracy, making it easy to achieve automated measurement.

Product Details

The company has developed a three-phase system suitable for voltage levels of 10kV and belowOvervoltage protector testerDetection device, used for debugging and testing of three-phase combined overvoltage protectors, in order to detect dangerous defects such as internal insulation moisture and valve plate aging as early as possible.

SHGB-50DOvervoltage protector testerTechnical Features

The instrument host adopts a high-strength, high insulation, wear-resistant hard plastic sealed box, which has the characteristics of beautiful appearance, durability, good shock resistance, high insulation level, and convenient on-site handling;

Technical indicators:

  1. Output voltage 0-40KV (peak value/√ 2); Output current 0-25mA

  2. Discharge detection method: waveform detection and Fourier transform method

  3. Accuracy: Voltage: ± (reading x 2%+0.1) Current: ± (reading x 2%+0.1)

  4. High voltage cut-off time: less than 0.2 seconds 5. Resolution: 0.1KV

  5. Input power supply: 180V~270VAC, 50Hz/60Hz ± 1%, powered by mains or generator

  6. Computer interface: standard RS232 interface 8. Printer: A7 thermal micro printer

Overvoltage protector tester successfully detects 1mA DC voltage

Performance characteristics:

1. The instrument uses waveform detection and Fourier transform to constantly monitor the discharge current. When the discharge current is detected, the high voltage is immediately recorded and the high voltage power supply is cut off within 0.2 seconds. The test results have high accuracy, making it easy to achieve automated measurement.

2. The instrument adopts a large screen LCD display, and the testing process is both intuitive and easy to operate through Chinese character menu prompts.

3. The instrument is easy to operate, and the measurement of data is automatically completed under the control of a microprocessor. No need for manual intervention

4. Integrated model with built-in high-voltage power supply for easy on-site testing and reducing on-site wiring

5. High voltage protection: In case of short circuit, breakdown or high voltage current fluctuation of the test sample, the output can be cut off at high speed in the form of a short circuit.

6. Low voltage protection: In case of accidental connection to 380V, power fluctuation or sudden power outage, the protection will be activated without causing overvoltage.

7. Anti misoperation: two-stage power switch; Real time monitoring of voltage and current; The high/low voltage of the wiring terminal is clearly defined; Slow boost, can quickly reduce pressure, sound alarm. 9. Seismic performance: The instrument adopts seismic design, which can withstand strong long-distance transportation vibrations and bumps without damage.

Overvoltage protector tester successfully detects 1mA DC voltageThe experimental parameters include AC operating voltage test with series gap overvoltage protection device and DC 1mA reference voltage test without gap overvoltage protection device and zinc oxide lightning arrester, with reliable data and high accuracy.

The accessory configuration is complete and can meet the testing site needs of various overvoltage protectors.

technical indicators

Power frequency discharge voltage test

Output voltage (AC): 0.00~30.0kV

Resolution: 0.1kV

Measurement accuracy: ± 1% ± 2 words

Test interval time: ≥ 15S

Automatically calculate the average value three times after testing and have optional printing function

DC 1mA reference voltage test

Rated output (DC): voltage 0-30kV, current 0-1000 μ A

Measurement range: Current 0-1000 μ A Voltage: 0-30.0 kVdc

Resolution: Current 1uA Voltage: 0.1kV

Measurement accuracy: ± 1% ± 1 word

Equipped with residual pressure automatic release function

Has optional printing function

Other parameters

Power supply method: Lead acid battery 12V/7Ah

Environmental temperature: -10 ℃ to+50 ℃

Relative humidity: RH ≤ 80%

Altitude:<1000 meters

Dimensions: Host: 380 × 280 × 210 mm

Test transformer: 255 × 150 × 255mm

Weight: Host: 5.8kg

Test transformer: 8.7kg