Original German Kracht flowmeter VC 16 F1 PS in stock $r $n Shanghai Weite Rui Industrial Development Co., Ltd. has excellent service and guaranteed reputation. Our company has a branch in Germany, and you can contact me anytime for inquiries about hydraulic and pneumatic products from European and American brands!

Product Details

Original German Kracht flowmeter VC 16 F1 PS in stock

POWER VC16The series gear flowmeter is from GermanyPOWERThe high-precision volumetric flow measurement equipment developed by the company uses a pair of precision meshing gears as measuring elements, and achieves flow measurement through the correspondence between the number of gear rotations and fluid volume. This series of products is widely used in the field of industrial fluid measurement due to its compact structure, high measurement accuracy, and strong stability

parameter item

technical indicators

model

VC16Series (includingVC16FTheVC16GEquivalent sub models)

Nominal Diameter

DN16(Connection caliber)16mm

measurement range

0.4~40 L/min(The specific range varies depending on the model and medium viscosity)

accuracy class

±0.1%(Reading) (Under standard conditions, water or mineral oil)

repetitiveness

≤±0.05%(Reading)

Applicable range of viscosity

0.3~100000 cSt

Temperature and pressure parameters

parameter item

technical indicators

Medium temperature range

-20℃~120℃(Standard type);-40℃~200℃(High temperature type, customized)

Environmental temperature range

-20℃~80℃

Maximum work pressure

250 bar(Standard type);400 bar(High voltage type, customized)

pressure loss

≤0.5 barAt maximum flow rate and viscosity30 cStWhen)

Output signal parameters

signal type

technical indicators

pulse output

TTL/HTLLevel, highest frequency10 kHz

Analog output (optional)

4~20 mAor0~10 V

Communication interface (optional)

RS485ModbusAgreement)

Functional scope

VC16The main functions of the series gear flowmeter include

Real time monitoring of fluid volume flow in pipelines through flow measurement, supporting instantaneous and cumulative flow measurement

Signal output provides pulse, analog, or digital signals for convenient communication withPLCTheDCSWaiting for control system integration

Medium adaptability is suitable for various clean and well lubricated liquids, such as mineral oil, hydraulic oil, diesel, water (material compatibility needs to be confirmed), etc

Adaptability to working conditions: stable operation within high pressure, medium to high viscosity, and a wide temperature range

Key elements of the usage processMedia requirements

The medium needs to be cleaned to avoid containing solid particles (it is recommended to install a filter with high filtration accuracy)≤50μm

Non lubricating media (such as water) need to confirm the compatibility of gear materials, and special materials (such as stainless steel) should be selected if necessary

The viscosity of the medium should be within the applicable range of the equipment, and low viscosity media(<1 cSt)May affect measurement accuracy

Flow and accuracy

Within the rated flow range (usually within the measuring range)10%~100%)The device can maintain high-precision measurement

below10%When measuring range, the accuracy may slightly decrease(±0.2%~±0.5%

In practical applications, it is necessary to choose the appropriate range according to the process requirements to avoid long-term operation under low flow or overload conditions

Temperature and pressure effects

Temperature changes may cause changes in the viscosity of the medium, thereby affecting measurement accuracy. It is recommended to use it under constant temperature or conditions with small temperature fluctuations, or to correct it through compensation algorithms

The system pressure needs to be stable to avoid severe pressure shocks, and pressure buffering devices should be installed if necessary

performance advantage

High precision measurement adopts precision grinding gears and advanced manufacturing processes to ensure±0.1%The measurement accuracy meets the requirements of metrological applications

Wide viscosity adaptability for high viscosity media (maximum)100000 cSt)Still able to maintain stable measurement, superior to other types of equipment such as turbine flow meters

Compact and durable structure with no vulnerable parts, small clearance between gears and housing, low wear, and long service life (generally up to)10Years and above)

High pressure tolerance standard type can withstand250 barHigh pressure, suitable for hydraulic systems, high-pressure lubrication and other scenarios

Stable and reliable signal output pulse signal with strong anti-interference ability, no zero drift, suitable for long-term continuous operation

Application Fields and Scenarios

VC16Typical application areas of the series gear flowmeter include

Industrial hydraulic system: monitoring the output flow of hydraulic pumps and the return flow of oil cylinders to achieve system status monitoring and fault diagnosis

Lubrication system: Measure the lubricating oil flow of components such as gearboxes and bearings to ensure lubrication effectiveness

Petrochemical industry: used for batch transportation and metering of crude oil, diesel, lubricating oil and other media

Construction machinery: hydraulic circuits installed in excavators, cranes, and other equipment to monitor the flow of critical components

Test bench: used as a standard flowmeter for performance testing of hydraulic components such as pumps and valves

Installation method

Pipeline installation

Use flange or threaded connection (depending on the model), and ensure that the inlet and outlet pipelines are coaxial during installation to avoid excessive stress

Suggest horizontal installation, with the gear shaft parallel to the ground; When installing vertically, it is necessary to ensure that the medium flows from bottom to top to avoid the accumulation of bubbles

Import and export require reserved straight pipe sections (import)≥10Double the diameter of the pipe, outlet≥5Multiple diameter), upstream installation of filter

electrical connection

The pulse signal line adopts shielded cable, away from strong electrical interference sources, and the shielding layer is grounded at one end

Analog output should pay attention to impedance matching with the receiving device to avoid signal attenuation

Precautions

Strictly control the cleanliness of the medium and the pollution level of the medium. Regularly replace the filter to prevent particle wear on the gear

Start and stop to avoid pressure shock caused by sudden start or stop. It is recommended to slowly adjust the valve

The maintenance cycle generally does not require regular maintenance. If there is a decrease in accuracy or leakage, it is necessary to check the wear of the gears or the aging degree of the seals

When material compatibility comes into contact with corrosive media, stainless steel material should be selected (such asVC16Stainless steel version of the series

It is recommended to calibrate once a year to ensure that the measurement accuracy meets the requirements (which can be sent to a professional organization or calibrated on-site using standard equipment)

POWER VC16The series gear flowmeter has become an ideal choice in the field of industrial fluid measurement due to its advantages of high precision, wide viscosity range, and high reliability. Its compact structure and flexible installation method enable it to adapt to complex working conditions, and it is widely used in industries such as hydraulic, lubrication, and petrochemical. During use, attention should be paid to the cleanliness of the medium, installation standards, and regular calibration to fully utilize the performance of the equipment and extend its service life

VC 12 F1 PS

VC 12 F1 PS/71

VC 12 F1 PS7220

VC 16 F1 PS

VC 12 K1 F1 P2 SH

VC 12 K1 F1 P2 SM

VC 12 K1 F1 P4 SK 7220

VC 16 K1 F1 P2 SH

Original German Kracht flowmeter VC 16 F1 PS in stock

Advantage brand supply of Shanghai Weite Rui:

Beinlich Baili Pump

E+H: Mass flow meter, level gauge, electrode

Atos: Hydraulic valves, proportional valves, solenoid valves, amplifiers, hydraulic pumps

Kracht: Flow meter, gear pump, relief valve, indicator

VSE: flowmeter, amplifier

Rickmeier: Gear pump

MEISTER: Flow meter

Burkert: Flow meters, valves, sensors, etc

HYDAC: sensors, relays, hydraulic valves, filters, measuring instruments, etc

Wandfluh: Low temperature valve, plug-in valve, directional valve, pressure reducing valve, amplifier, coil, etc

LINCOLN: Distributor, directional valve, oil injector, metering pump