Online hydrochloric acid concentration meterSuitable for online measurement of hydrochloric acid concentration in pipelines or storage tanks in caustic soda plants. The concentration meter can be inserted and installed, and the data can be displayed on site or remotely transmitted to DCS. The product is maintenance free and has a long service life.
Details introduction: It uses a sound frequency signal source to excite a metal tuning fork and make it vibrate freely at the center frequency. This frequency is related to the density of the liquid in contact. Therefore, by analyzing the frequency, the density of the liquid can be measured, and then temperature compensation can be carried out to eliminate the system's temperature drift; The concentration value at a temperature of 20 ℃ can be calculated based on the relationship between the density and concentration of the corresponding liquid.
Online hydrochloric acid concentration meterSuitable for various installation methods such as pipeline installation or container wall insertion installation, both dynamic and static can be measured, and installation methods include flange and clamp. Flange type and clamp type.
1. Adopting a 4-wire system for transmitting 4-20mA output
2. Concentration value 0-100.0% (20 ℃) displayed (1 decimal place); Real time display of five digit density values (four decimal places); Real time indication of current value and temperature
3. Can directly enter the instrument menu on-site to set parameters and debug, easy to operate
4. Equipped with pure water calibration, measurement value fine-tuning, and temperature compensation functions
5. Online real-time measurement, can be directly used for production process control
6. All parts in contact with liquids are made of 316 stainless steel material, which is safe, hygienic, and has good corrosion resistance.
Signal mode: 4-wire system
Output signal: 4~20mA (active output)
Power supply: 24VDC (external resistance components cannot be loaded or connected in series with PLC)
Concentration range: 0~100% (20 ℃), can be calibrated to a certain range according to usage conditions
Density range: 0-2g/ml, can be calibrated to a certain range according to usage conditions
Concentration accuracy: 0.5%, resolution: 0.1%, repeatability: 0.2%
Density accuracy: 0.003 g/ml, resolution: 0.0001, repeatability: 0.0005
Explosion proof grade: Explosion proof ExdII BT6
Work pressure:<1Mpa
Medium temperature: 0-60 ℃ (liquid) Environmental temperature: -40~85 ℃ Medium viscosity:<2000mpa · s
Electrical interface: M20X1.5
Process interface: Various specifications of flanges and clamps for liquid connection components: 316 stainless steel (or Ha C)