Online chromatography zero order air source

NegotiableUpdate on 12/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The CLA-3 online chromatography zero level air source is a device independently developed by the company to provide high-quality purified air for various online monitoring equipment. It consists of an air compression cooling system, a water removal system, a HC/CO removal reaction system, a special impurity purification system (such as NO, NO2, O3, SO2, H2S, NH3 need to be customized), and a final particulate matter zero gas output system.

Product Details

1、 Product Introduction

CLA-3Online chromatography zero order air sourceIt is a device independently developed by the company to provide high-quality purified air for various online monitoring equipment. The device consists of an air compression cooling system, a water removal system, a HC/CO removal reaction system, a special impurity purification system (such as NO, NO2, O3, SO2, H2S, NH3 need to be customized), and a final particulate matter zero gas output system. Its principle is to use an oil-free silent air compressor as the power source, and use a special combination of adsorption materials and PSA technology to dry and purify natural air, remove moisture and carbon dioxide. The total hydrocarbons in the compressed air are converted into carbon dioxide and water vapor in a heating catalyst containing platinum palladium support. After passing through the device for removing carbon dioxide and water, the hydrocarbon content is less than 0.1 ppm (calculated as methane) and the dew point is less than -60%. Zero level air at ℃.

2、 Product Technical Parameters

Output hydrocarbon concentration (such as methane) in the air:<0.1ppm

Output carbon dioxide concentration in the air:<1ppm

Output air pressure: adjustable from 0 to 0.35Mpa

High output flow rate: 100ml/min

Power supply: 220V ± 10% 50~60Hz

Power consumption: 150W

Environmental temperature range: 0-50 ℃

Operating environment humidity:<85%

Dimensions: Standard 19 inch 4U rack mounted chassis 537X482.6X177.8 (length X width X height)

Instrument weight: 24.8 Kg

IIICLA-3Online chromatography zero order air sourceProduct Display