Delger 8103560 Compressed Air Quality Tester Oil Detection Box for Pharmaceutical Industry

8103560Oil detection box Delger DRAEGER detection tube
Delger oil box 8103560 is used to detect the oil content in compressed air systems, with a range of 0.1-1.0 mg/m3. It is an upgraded version of Delger oil detection tubes. 10 pieces per box, used in conjunction with an oil box adapter, convenient and fast to use. Widely used in pharmaceutical factories and other enterprises that require compressed air quality testing. Due to the general compressed air pressure being 6-10BAR, the most commonly used is the Aerotest Alpha compressed air quality detector with a pressure range of 3-15BAR.
8103560Oil detection box Delger DRAEGER detection tube
Advantages of Delger oil detection box:
There are different detection limits for different concentrations (0.1/0.5/1.0 mg/m3)
There is a signal for all synthetic oils
Lower detection limit of 0.1 mg/m3
Easy to read
Not related to the type or viscosity of the oil
Product principle:
Compressed air is guided vertically into the impactor through 20 small holes to the engraved glass sensing platform. After entering the impactor, the air changes direction 90 degrees and separates oil mist substances in the air based on high inertia at the glass interface. The concave areas in the glass are filled with oil, which compensates for the scattered light caused by glass friction. This principle allows visual recognition of tiny amounts of oil mist. Due to the particularity of the orifice, the quality of the separated oil can be measured with high repeatability if the air quality is known and the concentration of the oil mist is known.
Product application:
Used to detect oil mist in compressed air
Standard measurement range: 0.1mg/m3, 0.5mg/m3, or 1.0mg/m3
Detection limit: 0.05mg/m3 oil mist
Surrounding environmental requirements:
Temperature: 10 ℃ to 30 ℃
Humidity: Maximum 60% relative humidity
Pressure: only applicable to compressed air that is not subjected to force
Notes:
1. Impactor can only be used in conjunction with Draeger Aerotest Simulator Alpha
2. The measurement results only provide data on the oil mist content extracted from the air sample used for measurement
3. Measurement must be carried out by the operating system
The temporal and spatial independence of the absorption and desorption processes on the surface should be considered in the assessment of oil mist content.