Delger Hazmat Simulintest industrial toxic gas detection box
Order number 4056098 HazMat Simultest Carrying Case with foam inserts only 4056458,HazMat Simultest Kit without accuro Pump 4056447, Used to detect toxic substances produced by burning combustible materials, flammable liquids or gases, as well as substances produced by chemical leaks or spills

Delger Hazmat Simulintest industrial toxic gas detection box
The Dr ä ger HazMat Simulintest Kit is designed to quickly determine the presence of inorganic and organic gases and vapors. The synchronous testing devices I, II, and III consist of five tube groups, used to detect toxic substances produced by the combustion of combustible materials, flammable liquids, or gases, as well as substances produced by chemical leaks or spills.
Save up to 50% of time
The Dr ä ger HazMat synchronous testing kit is a pre packaged set of 5 test tubes. Use a Dr ä ger 5-tube manifold to simultaneously draw in air through 5 tubes. Compared to using a single tube for approximately 10 minutes, the time required to extract an air sample is less than 1 minute.
Identify gases and vapors to improve safety
Group I and Group II are dedicated to inorganic gases, while Group III is dedicated to organic vapors. Set III can quickly identify the presence of ketones, aromatic hydrocarbons, alcohols, aliphatic and chlorinated hydrocarbons.
Reliable performance under harsh conditions
Reduce the impact of environmental factors such as temperature changes or high humidity on measurement results. This ensures reliable measurements under harsh environmental conditions. The contents of the kit are securely packaged in a sturdy box.
No calibration needed
The pipes are calibrated in the factory and have a shelf life of two years (stored at temperatures between 41-77 ° F). The Dr ä ger Accuro manual pump does not require calibration, only a simple leak test is needed to confirm that the pump will deliver the specified volume.
The HazMat Simultest Kit is ready for immediate use in emergency response situations. The measurement procedures for each group are the same, thus minimizing training to the greatest extent possible. Provide laminated full-color instruction cards to provide quick references for simple sampling procedures and accurate result interpretation.
CDS suite
The Civil Defense Simulintest (CDS) suite is based on the Dr ä ger Tube synchronous testing device and is used to examine blood, blisters, lungs, and nerve agents. Test five chemical reagents once per group.
CMS suite
The CMS emergency response kit combines measurement chips for specific substances with electronic analyzers, which display measurement results as digital readings. This kit includes 10 chips.