Drager X-pid VOC gas detector
Selective PID gas detection equipment is very suitable for users who frequently need to detect toxic and harmful substances. Benzene, butadiene, and other volatile organic compounds (VOCs) are carcinogenic even at the lowest concentrations. Due to the presence of other gases and vapors, it is necessary to conduct selective measurements. This gas measuring device can shorten detection time and provide laboratory quality test results.

Drager X-pid VOC gas detector
There are two models of this product: 9000 and 9500. The target compounds detected by Dr ä ger X-pid 9000 include benzene and butadiene. The Dr ä ger X-pid 9500 can combine over 23 target compounds into a single analytical program, thereby expanding its application range. This means that you can independently expand the target substance database for Dr ä ger X-pid 9500.
The advantage lies in two modes, which can achieve effective measurement. The "inspection" mode is a broad-spectrum measurement method used for pre detection and positioning of measurement points. It can continuously and directly read the total concentration measurement values of all volatile organic compounds. The "inspection" mode is similar to using a single PID gas measuring device.
The 'analysis' mode allows for selective measurement to monitor specific toxic compounds. In just a few seconds, the pre selected target compound can be accurately measured. The 'analysis' mode is similar to gas chromatography analysis performed in a laboratory.
Dr ä ger X-pid 9000/9500 can save up to 90% of time without preparation, and can be used immediately after quick startup. The selective measurement in the "analysis" mode can be completed in just a few seconds. To perform benzene measurement, simply press the button and it will take 30 seconds to complete. After a 60 second interval, the device can measure benzene again. Compared to other detection systems, Dr ä ger X-pid 9000/9500 can save a lot of time and enable further monitoring. Simultaneously measuring other compounds such as benzene and butadiene further reduces detection time.
Cost savings can be achieved by reducing operational costs as measurements do not require the use of consumables. For users with high measurement needs, Dr ä ger X-pid 9000/9500 can quickly recoup costs. For example, it does not require a pre detection tube, which makes it more convenient to use and prevents user errors. Based on 200 measurements per year, the Dr ä ger X-pid 9000/9500 is typically more cost-effective than similar measurement systems.
The high selectivity and safer selective measurement "analysis" mode relies on the technology of separating individual compounds in the mixed gas. This makes it possible to perform specific compound measurements for benzene, even in the presence of high concentrations of other volatile organic compounds such as toluene and xylene. The cross sensitivity of benzene can be reduced to a low level. This can reduce false positive measurement results and false alarms.
Even in harsh environments, reliable performance can be maintained, and the impact of various environmental factors (such as variable ambient temperature or high humidity) on measurement results can be minimized. The sensor unit maintains a constant temperature above the ambient temperature and then separates the target compound from the mixed vapor. This ensures reliable measurement values can be obtained even under harsh environmental conditions.
The concentration of toxic compounds in the air of workplaces with low detection limits shall not exceed the threshold limit. For carcinogenic vapors such as benzene, their time weighted average must be calculated within the low concentration range of ppb to ppm. The Dr ä ger X-pid 9000/9500 has been optimized to measure within this concentration range and can detect benzene at concentrations above 50ppb.
Intuitively operate the sensor unit and process measurement data through the mobile application installed on the explosion-proof smartphone (provided upon delivery). Adopting a large touch screen and familiar user interface elements for easy use. This enables a wide range of user groups to use complex technologies. No professional background knowledge or comprehensive training is required.
The gas measurement equipment with laboratory quality measurement results is based on gas chromatography analysis (GC) and photoionization detection (PID) technology. These techniques are commonly used in laboratories and are highly regarded for their excellent analytical performance. Dr ä ger X-pid 9000/9500 can directly apply these technologies to hazardous areas in all production sites.
Convenient functional testing and calibration can be completed in just two minutes using test gases isobutene and toluene, followed by the use of Dr ä ger X-pid 9000/9500. During the testing process, the system will gradually guide users to complete the user interface operations. The calibration will be completed in approximately four minutes.
There are two models of this product to meet different needs: 9000 and 9500. The target compounds detected by Dr ä ger X-pid 9000 include benzene and butadiene. The Dr ä ger Xpid 9500 can combine over 23 target compounds into a single analytical program, thereby expanding its application range. This means that you can independently expand the target substance database for Dr ä ger X-pid 9500.
Raw & & X-pid
List of target compounds in 9000/9500 "Analysis" mode
Raw & & X-pid
The target compounds of 9000 are limited to benzene and 1,3-butadiene. Dräger X-pid
9500 is suitable for the following target compounds.
Compound CAS number
Acrylic Quan 107-02-8
Benzene 71-43-2
1,3-Butadiene 106-99-0
2-butanone 78-93-3
Butyl acrylate 141-32-2
Chlorobenzene 108-90-7
1,1-Dichloroethylene 75-35-4
Cis-1,2-dichloroethylene 156-59-2
Trans-1,2-dichloroethylene 156-60-5
Epichlorohydrin 106-89-8
Ethyl acetate 141-78-6
Ethyl acrylate 140-88-5
Ethylbenzene 100-41-4
Ethylene oxide 75-21-8
N-hexane 110-54-3
Isobutene 115-11-7
Methyl acrylate 96-33-3
Methyl Bromide 74-83-9
Phosphine 7803-51-2
Epoxy propane 75-56-9
Styrene 100-42-5
Tetrachloroethylene 127-18-4
* 109-99-9
Toluene 108-88-3
Trichloroethylene 79-01-6
9000/9500
9000/9500 sensor unit.
9000, including sensor unit, control unit, pre installed mobile applications, power supply, and charging
9500, including sensor unit, control unit, pre installed mobile applications, power supply, and charging
9500 AUS/SGP, Including sensor unit, control unit, and pre installed mobile applications, electricity
9500 CAN, Including sensor unit, control unit, pre installed mobile application, power supply
Mobile applications upgraded from version 9000 to version 9500 68 51 849
9000/9500 Test Gas Adapter 68 51 850
Outer box of 9000/9500 68 51 851