1Non standard specification constant temperature and humidity test chamber used for medical device productsBasic specification parameters:
parameter item |
technical indicators |
model |
ADX-TH-1500D (non-standard customized version) |
internal volume |
1500L (precise adaptation to large medical devices and batch sample testing) |
Inner container size(W×D×H) |
1320 × 750 × 1520mm (can be adjusted according to non-standard medical device dimensions) |
External dimensions(W×D×H) |
1780 × 1030 × 1865mm (including base and heat dissipation structure) |
Standard pallet quantity |
2layer SUS304 stainless steel shelf, adjustable spacing |
power supply voltage |
AC 380V 50Hz |
installed power |
15.5KW |
operating power |
about900W (energy-saving design, suitable for long-term continuous testing) |
Work environment requirements |
ambient temperature5 ℃~30 ℃, relative humidity ≤ 85% RH, no strong vibration or dust |
IINon standard specification constant temperature and humidity test chamber used for medical device productsTemperature and humidity control parameters:
parameter item |
technical indicators |
Temperature control range |
Non-standard customization -40 ℃~100 ℃ (conventional range -5 ℃~70 ℃, can be extended to -70 ℃~150 ℃ as needed) |
Moisture control range |
Non-standard customization 10% RH to 95% RH (conventional range 15% RH to 95% RH, both low and high humidity can be accurately controlled) |
temperature resolution |
0.1℃ |
temperature fluctuation |
± 0.2 ℃ (unloaded, 25 ℃/60% RH standard operating conditions) |
Temperature Uniformity |
± 0.5 ℃ (multi-point testing inside the box, meeting the uniformity requirements for medical device testing) |
Humidity fluctuation |
± 1% RH (unloaded, 25 ℃/60% RH standard operating conditions) |
heating rate |
0 ℃~100 ℃, 3 ℃/min (unloaded, customizable high-speed heating scheme) |
降温速率 |
100 ℃~0 ℃, 1 ℃/min (unloaded, using imported refrigeration system, stable cooling without overshoot) |
Temperature and humidity control method |
Microcomputer fuzzyPID control, programmable with 30 segments and 99 cycle times, supporting gradient and slope control |
3、 Core system configuration:
System Category |
Configuration Details |
refrigeration system |
Imported fully enclosed compressor Taikang, hot gas bypass energy regulation technology; Forced air cooling condensation,R404A and R23ANon fluorine environmentally friendly refrigerant, dehumidification adopts evaporator coil dew point dehumidification method, key components such as solenoid valve and drying filter are all imported |
Heating and humidification system |
Far infrared nickel alloy high-speed heating electric heater, with uniform and stable heating; External boiler steam humidifier with automatic water replenishment and recycling design, water-saving and worry free, stable humidification without scaling |
circulatory system |
Diffusion type new air duct, high, medium, and low speed adjustable fans, forced convection (balanced), ensuring temperature and humidity uniformity inside the box; Independent ventilation fan to promptly dissipate the operating heat of the equipment |
control system |
7-inch color touch screen, real-time display of temperature and humidity, fan speed, running time and other parameters; Supports USB interface, RS485 interface, can be connected to printers or computers to achieve data recording, export, and remote control; Equipped with parameter memory and automatic power-off recovery function |
4、 Box structure and material:
Structural parts |
Material and Design Details |
inner liner |
ImportSUS304 mirror stainless steel, with a four corner arc design, easy to clean and corrosion-resistant, meeting the cleanliness requirements for medical device testing |
outer box |
High quality cold-rolled steel plate+Powder spraying treatment, uniform thickness, beautiful and durable, scratch resistant |
insulation layer |
Three layer high-density polyurethane insulation material, thickness100mm, Thermal insulation performance meets international standards, effectively reducing energy consumption |
box door |
Double layer design (outer cold-rolled steel plate sprayed with plastic)+Inner tempered glass with strong sealing properties; Glass inner door with electronic defrosting film, equipped with auxiliary lighting, easy to observe and does not affect temperature and humidity |
Base and casters |
Rectangular square steel integrated welded base with high strength; Polyurethane universal casters, with steering lock, easy to move and wear-resistant |
test hole |
Standard configuration on the left side of the boxΦ 50mm test hole, equipped with silicone soft plug, convenient for external monitoring equipment, isolated from air convection |