Large high and low temperature test chamber for firefighting equipment

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The large-scale high and low temperature test chamber for firefighting equipment can accurately control a wide temperature range of -50 ℃~180 ℃, simulating the high temperature (above 60 ℃) around the fire scene in Hubei during summer and the low temperature (below -30 ℃) during winter duty in northern China. For example, testing the starting performance of the fire truck water pump system at -25 ℃ low temperature to avoid water supply interruption caused by pipeline icing; Verify the pressure resistance of the fire extinguisher casing when stored at a high temperature of 80 ℃ to prevent the risk of explosion.

Product Details

OneLarge high and low temperature test chamber for firefighting equipmentMain technical indicators

Model: ADX-GDW-1675B

1. Inner box size: 800mm (W) × 1550mm (H) × 1350mm (D)

2. Outer box size: 1050mm (W) × 2250mm (H) × 2890mm (D) (excluding protruding parts)

3. Temperature range: -40 ℃ to 100 ℃;

4. Temperature fluctuation: ≤± 0.5 ℃

5. Temperature deviation: ≤± 3 ℃

6. Heating time: within 40 minutes at RT ∽+100 ℃; (Under no-load conditions)

7. Cooling time: RT ∽ -40 ℃ within 60 minutes; (Under no-load conditions)

8. This device cannot be used to test or store items containing flammable, explosive, or volatile or corrosive gases

Note: The above indicators were measured at room temperature of+25 ℃ without a sample

消防器械大型高低温试验箱



IILarge high and low temperature test chamber for firefighting equipmentBox structure and materials:

1. Shell material: Steel plate with electrostatic spraying surface treatment.

2. Inner box material: SUS # 304 heat-resistant and cold resistant mirror stainless steel plate.

3. Thermal insulation material: rigid polyurethane foam+glass fiber;

4. Standard configuration: 2 observation windows (transparent electric heating film insulated glass), 1 50mm cable hole (located on the left side of the box), 2 sets of sample racks, 1 lighting lamp, 4 casters, and 1 power cord (5 meters long)


III Freezing system and heating system:

1. Heater: Electric heating tube heater

2. Refrigeration unit

(1) Freezing method: air-cooled

(2) Compressor: French Taikang fully enclosed compressor,

(3) Refrigerant: R404A/R23 environmentally friendly refrigerant (DuPont, USA)

(4) Condenser: Shell and tube condenser

(5) Evaporator: Slope type FIN-TUBE evaporator


4 Supply air circulation system:

1. Adopt a multi blade centrifugal circulating fan, reinforced with an axis and aluminum alloy rotating blades that are resistant to high and low temperatures, to achieve forced convection

2. FLOW THOW air supply method; Horizontal diffusion, vertical heat exchange, arc-shaped cycle

3. Adjustable side blowing air outlet and protective net return air outlet


Five controller:

1.7-inch high-definition color touch screen, with 65000 true colors and a resolution of 800 * 480. The core controller is PLC, which has a long service life, strong anti-interference ability, high control accuracy, fast data processing speed, and multiple signal combination relays (transistors) output. The signals can be logically processed (NOT, AND, OR, NOR, XOR)

2. Temperature and humidity 2-channel input, independently controlled, capable of 10 point linear slope compensation for each temperature and humidity of nonlinear sensors; There are two control modes for each channel: fixed value/program fixed value. The maximum time can be set to 9999999 hours; Program editing and looping, the program can be programmed with 100 groups, each consisting of 100 segments, supporting free combination programming to output high difficulty controls such as serial and parallel.

3. Equipped with Chinese character input function, edit and input manufacturer information, fault alarm name, test name, data group name, etc

4. Communication function: The instrument is equipped with a USB interface, which supports USB storage, exporting historical curves, and data functions, and can be viewed and printed using computer software

5. Interface type: Chinese/English can be freely selected and switched; Temperature and humidity control and single temperature control display can be freely selected

6. Compressor delay function; Manual, automatic, and timed shutdown functions; Appointment activation function

7. 4 internal alarms and 8 external alarm functions can be customized, and the external input DI alarm signal can be freely switched between normally closed or normally open signal modes

8. The instrument is equipped with an alarm buzzer, which can freely set whether to delay the output when the alarm is triggered, how long to delay, whether to stop the machine, whether the buzzer will sound an alarm, whether the alarm interface will pop up, whether to output external alarm points, and other functions; In case of hardware failure at the input/output point, the backup function of moving the point; Water shortage prompt, automatic replenishment; Automatic alarms for overheating, overload, etc

9. The controller can display the current operating status in real time, such as set values, real-time values, running time, number of groups and segments, number of cycles, and other main process parameters, as well as statistical data; Various control parameters can be set arbitrarily

10. Real time display of temperature and humidity PV/SP curves; And it can also query historical curves


VI Security protection system:

1. System control circuit fuse

2. Equipped with a non fuse protection switch

3. Overtemperature Water cut-off overheat protection switch

4. Overload protection device for refrigeration compressor

5. System overcurrent protection device

6. Fault indicator light

7. Controller setting error, fault display and warning


7 Equipment usage conditions:

1. Environmental temperature: 5 ℃ -35 ℃;

2. Relative humidity: ≤ 85% RH;

3. Power supply voltage: 380V AC (± 10%), single-phase wire+protective ground wire, grounding resistance ≤ 4 Ω;

4. Frequency: 50 ± 0.5Hz

5. Power switch: Air switch (40A, prohibit the use of knife switches or power sockets);

6. Power: 25KW;

7. Humidification water; Electrical resistivity ≥ 500M Ω;

8. Requirements for ambient air quality; Does not contain high concentration dust and is flammable Explosive gases or dust, with no strong electromagnetic radiation sources nearby