- Phone
-
Address
Building 6, Optics Valley Electromechanical Industrial Park, No. 84 Gaoxin 5th Road, Donghu New Technology Development Zone, Wuhan City, Hubei Province
Wuhan Ultra High Voltage Power Technology Co., Ltd
Building 6, Optics Valley Electromechanical Industrial Park, No. 84 Gaoxin 5th Road, Donghu New Technology Development Zone, Wuhan City, Hubei Province
UHV (J) series device parameters:
Inflatable non partial discharge test transformer
| Rated capacity | 25kVA |
| input voltage | 380V±10% |
| output voltage | 0-100kV |
| Partial discharge of the system under rated voltage | ≤5PC |
| output current | 250mA |
| voltage accuracy | AC 1.5% |
| Power distortion degree | <3% |
| insulating medium | SF6 gas |
| Overall dimensions | Outer diameter: 520mm, height: 1200mm |
| weight | 160kg |
Non partial discharge regulator control box
| Rated capacity | 25kVA |
| input voltage | 380V±10% |
| output voltage | 0-430V |
| output current | 62.5A |
| Overall dimensions | 600mm×580mm×1200mm |
| weight | 150kg |
Isolation filter transformer
| Rated capacity | 25kVA |
| input voltage | 380V±10% |
| output voltage | 380V±10% |
| no-load loss | ≤5% |
| impedance voltage | ≤5% |
| Attenuation effect | 10kHz-100kHz≥ 20db |
| 100kHz-30MKz≥ 60db | |
| Overall dimensions | 500mmx300mmx550mm |
| weight | 120kg |
Non partial discharge capacitor voltage divider
| high | 900mm |
| capacitance | 500-1000PF |
| Local volume | ≤5PC |
No partial discharge protection resistor
| Overall dimensions | Diameter 60mm x length 600mm |
| weight | 3kg |
Note:
1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. If there is any act of theft or copying, legal responsibility will be pursued.
2. For more information on ultra-high voltage products, please enter the product center.
Product features
1. This console is a dedicated high-voltage non partial discharge test regulating and operating platform, equipped with start and stop buttons; Digital voltage, ammeter indication, time relay control time and alarm.
2. The operating voltage is continuously adjustable, and the waveform has no distortion or distortion.
3. It has zero position function, voltage upper and lower limits, overcurrent, and overvoltage breakdown protection functions.
4. The alarm has sound and light prompts.
5. The experiment is over, and the voltage is reduced to zero.






Product Video Product Atlas
Product Attachment Diagram
complete set
Inflatable non partial discharge test transformer
Non partial discharge regulator operation console
Isolation filter transformer
Coupling capacitor voltage divider
No partial discharge protection resistor
High power non partial discharge withstand voltage test device
Product detail images
Inflatable non partial discharge test transformer
terminal
terminal
pressure gauge
Control Panel
Current meter head
Voltmeter head
Overcurrent protection relay
Isolation filter transformer
terminal
Coupling capacitor voltage divider
Coupling capacitor voltage divider base