New product with PROFINET system 8652 Burkert valve island

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

New product with PROFINET system 8652 Burkert valve island $r $nB #252; RKERT's 8652 valve island $r $n now supports S2 level redundant systems based on PROFINET communication. Today, $r $n will take you on a deeper understanding of its advantages.

Product Details


B ü rkert's 8652 valve island

We still support it nowbased onPROFINETcommunication

S2 levelRedundant system

Today, we will take you to gain a deeper understanding of its advantages.





New product with PROFINET system 8652 Burkert valve island

新品带 PROFINET 系统 8652 型Burkert阀岛


Redundant systems are fault-tolerant hot backup measures in high-risk process industries or infrastructure. It can be found in:

  • When the primary system fails, the secondary system in hot backup can immediately and undisturbed take over the control tasks of the original system and downstream equipment.
  • Ensure that some process equipment and facilities can still reliably guarantee continuous safe production in the event of faults and errors;
  • This can effectively control the problem of downtime caused by abnormal equipment/environment
  • Enhance reliability and reduce security risks.

Therefore, industries and fields assessed as high-risk, such as pharmaceuticals, chemicals, aerospace, etc., all propose such special control redundancy requirements.



01

8652 valve island supports based onPROFINET Communication

S2 level redundancy, whichHigher system availability





If equipment, facilities or control systems fail, enterprises will bear huge economic losses due to equipment downtime and production delays caused by equipment failures. Therefore, Burkert, Germany8652 type valve island, in additionMRPIn addition to the Media Redundancy Protocol, S2 based on PROFINET has also been addedredundant control.


新品带 PROFINET 系统 8652 型Burkert阀岛
The combination of PROFINET S2 redundancy and MRP (Media Redundancy Protocol) solves two key problems:Equipment single link communication interruption (left) and redundant dual control system master-slave hot standby switching (right).








02

Media Redundancy Protocol (MRP) can avoid the occurrence of a single communication link

When there is a technical malfunction, it causes communication interruption and loss of control of the equipment in the later stage





We look forward to your joining and growing together with us,Create a better future together. We promise to provide you with a fair, just, and harmonious working environment, allowing you to enjoy the joy of work while showcasing your talents.

If the communication connection of the 8652 model is interrupted (such as due to line interruption), the valve island will switch to the backup communication link, and data collection will continue through communication on the backup link, thus avoiding the need for on-site layer ordevice layerCommunication failure occurred due to communication link interruption.

But if the programmable logic controller (PLC) malfunctions, this function cannot avoid downtime and loss of control.



03

Redundant S2 can be avoided through PROFINET system

When a technical malfunction occurs in the system control, it leads to overall failure




We look forward to your joining and growing together with us, creating a better future together. We promise to provide you with a fair, just, and harmonious working environment, allowing you to enjoy the joy of work while showcasing your talents.

Through the master and slave PROFINET interfaces, the 8652 Burkert valve island can now be connected to both master and slave systems simultaneously and receive control.If the primary PLC fails or requires maintenance, the second backup PLC and its connected PROFINET network shall be used for uninterrupted data exchange.

Thus, through the architecture of redundant PLC+redundant communication+redundant remote substation, the system availability is ensured at the control level. Redundant systems can effectively reduce the risk of equipment failures to process production, eliminate the huge losses and safety risks caused by unpredictable downtime to production.





advantage

➤ Based on MRP and PROFINET S2 redundancy, higher process reliability and system availability can be achieved
When the main controller and main link fail, it can switch to the slave controller and slave link without disturbance, ensuring continuous production

新品带 PROFINET 系统 8652 型Burkert阀岛AdditionallyNew product with PROFINET system 8652 Burkert valve islandDue to its focus and professionalism, the 8652 Burkert valve island has also received recognition from the International PI OrganizationPROFINET S2 redundancy certificate, the testing of which is undertaken and completed by Siemens Germany - Automation and Drive Group.

新品带 PROFINET 系统 8652 型Burkert阀岛