Burkert flowmeter rotor 551763 FLOW S030 SSTEPDM sealing ring is used for disinfection equipment in pharmaceutical companies. Irregular stocking, good discounts on genuine products, and fast delivery.
Flow meter rotor/rotor/FLOW S030 SST WHEEL/Burkert
The turbine rotor component model corresponding to Burkert turbine flowmeter base 005610130055416900553022 is 00551763. It is used for disinfection and is generally used by pharmaceutical companies and users.
Burkert flowmeter base 00562495 is the complete model of S030 base (corresponding to rotor accessory SET8 model 551764)
German Burkert flowmeter DN20 base repair turbine parts SET8 brass FKM seal PVDF white turbine 00432304
BurkertFlow meter rotor component 00551763 stainless steel arrival drawing:


Burkert turbine flowmeter rotor components00432304 brass delivery drawing:


There are also Burkert flowmeter turbine rotor components such as 551764432305.
Suggestions on selecting Burkert flowmeter types for purified water or injection water equipment!
Burkert turbine flowmeterIt is strictly prohibited to pass bubbles, especially on the impeller. There should be no bubbles or start stop vibrations. (Actually, as long as there are bubbles in the pipeline, anything used will not be accurate.)
At the front end of the equipment pipeline, if bubbles are generated, it is recommended to use a Burkert electromagnetic flowmeter (except for the medium deionized water, which is not recommended, everything else is fine). The electromagnetic flowmeter will at least be inaccurate. This turbine is extremely expensive, in short, it requires too many turbine accessories, either the impeller is damaged or the turbine shaft is broken!!!
The main reason why the turbine shaft of the SET8 rotor accessory on the S030 base of the Burkert turbine flowmeter is prone to breakage is:
If the Burkert flowmeter turbine shaft keeps breaking, it's really not the shaft's fault. Normally, it wouldn't break so quickly. It must be a problem with the user's pipeline!!!
Mainly, there are impurities and small bubbles in the medium, and another possibility is that the back end of the pipeline starts and stops too quickly, which can cause water hammer due to the large reverse impact and lead to the fracture of the turbine shaft.
Burkert flowmeter rotor 551763 FLOW S030 SSTTechnical Specifications:
| feature | |
|---|---|
Type
SET8
|
|
Type 2
S030
|
|
Port connection
not applicable
|
|
Material
stainless steel
|
|
Seal material
EPDM
|
|
Sensor
metal paddlewheel
|
|
function sensor
without
|
|
Design
without
|
|
Voltage
without
|
|
Frequency
without
|
|
Output signal
standard
|
|
Special feature
for medium temperature up to 125°C and pressure range PN 40 bar
|