Welcome Customer !

Membership

Help

Shanghai Weixin Automation Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Weixin Automation Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    Building C, No. 888 Huanhu West Second Road, Pudong New Area, Shanghai

Contact Now

Burkert flowmeter rotor 551763 FLOW S030 SST

NegotiableUpdate on 05/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Burkert flowmeter rotor 551763 FLOW S030 SST EPDM sealing ring for pharmaceutical disinfection equipment. Irregular stocking, good discounts on genuine products, and fast delivery. The turbine rotor component model corresponding to the base 00561013005541690053022 of the $r $nBurkert turbine flowmeter is 00551763. It is used for disinfection and is generally used by pharmaceutical companies and users.

Product Details

Burkert flowmeter rotor 551763 FLOW S030 SSTEPDM sealing ring is used for disinfection equipment in pharmaceutical companies. Irregular stocking, good discounts on genuine products, and fast delivery.

Flow meter rotor/rotor/FLOW S030 SST WHEEL/Burkert

The turbine rotor component model corresponding to Burkert turbine flowmeter base 005610130055416900553022 is 00551763. It is used for disinfection and is generally used by pharmaceutical companies and users.

Burkert flowmeter base 00562495 is the complete model of S030 base (corresponding to rotor accessory SET8 model 551764)

German Burkert flowmeter DN20 base repair turbine parts SET8 brass FKM seal PVDF white turbine 00432304


BurkertFlow meter rotor component 00551763 stainless steel arrival drawing:

Burkert流量计转子部551763 FLOW S030 SSTBurkert流量计转子部551763 FLOW S030 SST

Burkert turbine flowmeter rotor components00432304 brass delivery drawing:

Burkert流量计转子部551763 FLOW S030 SST

Burkert流量计转子部551763 FLOW S030 SST

There are also Burkert flowmeter turbine rotor components such as 551764432305.


Suggestions on selecting Burkert flowmeter types for purified water or injection water equipment!

Burkert turbine flowmeterIt is strictly prohibited to pass bubbles, especially on the impeller. There should be no bubbles or start stop vibrations. (Actually, as long as there are bubbles in the pipeline, anything used will not be accurate.)

At the front end of the equipment pipeline, if bubbles are generated, it is recommended to use a Burkert electromagnetic flowmeter (except for the medium deionized water, which is not recommended, everything else is fine). The electromagnetic flowmeter will at least be inaccurate. This turbine is extremely expensive, in short, it requires too many turbine accessories, either the impeller is damaged or the turbine shaft is broken!!!

The main reason why the turbine shaft of the SET8 rotor accessory on the S030 base of the Burkert turbine flowmeter is prone to breakage is:

If the Burkert flowmeter turbine shaft keeps breaking, it's really not the shaft's fault. Normally, it wouldn't break so quickly. It must be a problem with the user's pipeline!!!

Mainly, there are impurities and small bubbles in the medium, and another possibility is that the back end of the pipeline starts and stops too quickly, which can cause water hammer due to the large reverse impact and lead to the fracture of the turbine shaft.


Burkert flowmeter rotor 551763 FLOW S030 SSTTechnical Specifications:

feature
Type
SET8
Type 2
S030
Port connection
not applicable
Material
stainless steel
Seal material
EPDM
Sensor
metal paddlewheel
function sensor
without
Design
without
Voltage
without
Frequency
without
Output signal
standard
Special feature
for medium temperature up to 125°C and pressure range PN 40 bar